Diagnostic Software, Trouble Shooting and Test Instructions
EN 35
DVD963SA
5.
5.8.2
Basic Engine Nuclei
8060
DAC Mode DSD OK
8061
DAC Mode DSD I2C bus busy
8062
DAC Mode DSD I2C failed
8100
DAC Low Power Standby On OK
8101
DAC Low Power Standby On I2C bus busy
8102
DAC Low Power Standby On I2C failed
8120
DAC Low Power Standby Off OK
8121
DAC Low Power Standby Off I2C bus busy
8122
DAC Low Power Standby Off I2C failed
8200
DAC Upsample 192k OK
8201
DAC Upsample 192k I2C bus busy
8202
DAC Upsample 192k I2C failed
8220
DAC Upsample 96k OK
8221
DAC Upsample 96k I2C bus busy
8222
DAC Upsample 96k I2C failed
8240
DAC UpSample On OK
8241
DAC UpSample On bus busy
8242
DAC UpSample On I2C failed
8260
DAC UpSample Off OK
8261
DAC UpSample Off bus busy
8262
DAC UpSample Off I2C failed
Error
code
Error text
3900
Test successful
3901
“Parity error from Basic Engine to Serial”
3902
“Unexpected response from Basic Engine”
3903
“Communication time-out error”
3904
“Basic Engine returned error number 0xXX”
3921
“Parity error from Basic Engine to Serial”
3922
“Unexpected response from Basic Engine”
3923
“Communication time-out error”
3924
“Basic Engine returned error number 0xXX”
3800
Test successful
3801
“Parity error from Basic Engine to Serial”
3802
“Unexpected response from Basic Engine”
3803
“Communication time-out error”
3804
“Basic Engine returned error number 0xXX”
3805
“Focus loop could not be closed”
3820
Test successful
3821
“Parity error from Basic Engine to Serial”
3822
“Unexpected response from Basic Engine”
3823
“Communication time-out error”
3824
“Basic Engine returned error number 0xXX”
4200
Test successful
4201
“Parity error from Basic Engine to Serial”
4202
“Unexpected response from Basic Engine”
4203
“Communication time-out error”
4204
“Basic Engine returned error number 0xXX”
4205
“Sledge could not be moved to home
position”
4206
“Focus loop could not be closed”
4207
“Motor not on speed within time-out”
4208
“Radial loop could not be closed”
4209
“PLL could not lock in accessing or tracking
state”
Error
code
Error text
4210
“Subcode or sector information could not be
read”
4211
“Requested subcode item could not be
found”
4212
“TOC could not be read in time”
4213
“Seek could not be performed”
4220
Test successful
4221
“Parity error from Basic Engine to Serial”
4222
“Unexpected response from Basic Engine”
4223
“Communication time-out error”
4224
“Basic Engine returned error number 0xXX”
4225
“Sledge could not be moved to home
position”
4226
“Focus loop could not be closed”
4227
“Motor not on speed within time-out”
4228
“Radial loop could not be closed”
4229
“PLL could not lock in accessing or tracking
state”
4230
“Subcode or sector information could not be
read”
4231
“Requested subcode item could not be
found”
4232
“TOC could not be read in time”
4233
“Seek could not be performed”
4240
Test successful
4241
“Parity error from Basic Engine to Serial”
4242
“Unexpected response from Basic Engine”
4243
“Communication time-out error”
4244
“Basic Engine returned error number 0xXX”
4245
“Sledge could not be moved to home
position”
4246
“Focus loop could not be closed”
4247
“Motor not on speed within time-out”
4248
“Radial loop could not be closed”
4249
“PLL could not lock in accessing or tracking
state”
4250
“Subcode or sector information could not be
read”
4251
“Requested subcode item could not be
found”
4252
“TOC could not be read in time”
4253
“Seek could not be performed”
4000
Test successful
4001
“Parity error from Basic Engine to Serial”
4002
“Unexpected response from Basic Engine”
4003
“Communication time-out error”
4004
“Basic Engine returned error number 0xXX”
4005
“Radial loop could not be closed”
4020
Test successful
4021
“Parity error from Basic Engine to Serial”
4022
“Unexpected response from Basic Engine”
4023
“Communication time-out error”
4024
“Basic Engine returned error number 0xXX”
4400
Test successful
4401
Test successful
4100
Test successful
4101
“Parity error from Basic Engine to Serial”
4102
“Unexpected response from Basic Engine”
4103
“Communication time-out error”
Error
code
Error text
Содержание DVD963SA
Страница 26: ...Diagnostic Software Trouble Shooting and Test Instructions EN 40 DVD963SA 5 Personal Notes ...
Страница 41: ...Electrical Diagrams 55 DVD963SA 7 Layout AV Board Part 1 Bottom Side CL 26532105_12a eps 280802 ...
Страница 42: ...56 DVD963SA 7 Electrical Diagrams Layout AV Board Part 2 Bottom Side CL 26532105_12b eps 280802 ...
Страница 46: ...60 DVD963SA 7 Electrical Diagrams Layout Display Panel Part 1 Bottom Side CL 26532105_16a eps 280802 Part 1 ...
Страница 47: ...Electrical Diagrams 61 DVD963SA 7 Layout Display Panel Part 2 Bottom Side CL 26532105_16b eps 280802 Part 2 ...
Страница 52: ...66 DVD963SA 7 Electrical Diagrams Layout P Scan Board Part 1 Top Side ...
Страница 53: ...Electrical Diagrams 67 DVD963SA 7 Layout P Scan Board Part 2 Top Side ...
Страница 55: ...Electrical Diagrams 69 DVD963SA 7 Layout P Scan Board Part 1 Bottom Side ...
Страница 56: ...70 DVD963SA 7 Electrical Diagrams Layout P Scan Board Part 2 Bottom Side ...