SAFETY PRECAUTIONS
VER1.0
1-2
4. Hot Chassis Warning
—
a.
Some Monitor chassis are electrically connected directly to one conductor of
the AC power cord and may be safely serviced without an isolation transformer only if the AC power plug
is inserted so that the chassis is connected to the ground side of the AC power source. To confirm that the
AC power plug is inserted correctly, with an AC voltmeter measure between the chassis and a known
earth ground. If a voltage reading in excess of 1.0V is obtained, remove and reinsert the AC power plug in
opposite polarity and again measure the voltage potential between the chassis and a known earth ground.
b.
Some Monitor chassis normally have 85V AC (RMS.), between chassis and earth ground regardless of
the AC plug polarity. These chassis can be safely serviced only with an isolation transformer inserted in
the power line between the receiver and the AC power source, for both personnel and test equipment
protection.
c.
Some Projection Monitor chassis have a secondary ground systems in addition to the main
chassis ground. This secondary ground system is not isolated from the AC power line. The two ground
system are electrically separated by insulating material that must not be defeated or altered.
5.
Observe original lead dress. Take extra care to assure correct lead dress in the following areas:
a.
near
sharp edges,
b.
near thermally hot parts
—
be sure that leads and components do not touch thermally hot
parts,
c.
the AC supply,
d.
high voltage,
e.
antenna wiring. Always inspect in all areas for pinched,
out-of-place, or frayed wiring. Do not change spacing between components, and between components
and the printed-circuit board. Check AC power cord for damage.
6.
Components, parts, and/or wiring that appear to have overheated or are otherwise damaged should be
replaced with components, parts, or wireing that meet original specifications. Additionally, determine the
cause of overheating and/or damage and, if necessary, take corrective action to remove any potential
safety hazard.
7.
PRODUCT SAFETY NOTICE
—
Many Monitor electrical and mechanical parts have special safety-related
characteristics some of which are often not evident from visual inspection, nor can the protection they give
necessarily be obtained by replacing them with components rated for higher voltage, wattage, etc. Parts
that have special safety characteristics are identified in this service data by shading with a mark on
schematics and by shading or a
*
mark in the parts list. Use of a substitute replacement part that does
not have the same safety characteristics as the recommended replacement part in this service data parts
list might create shock, fire, and/or other hazards.