Service Modes, Error Codes, and Fault Finding
5.
5.4
Stepwise Start-up
There are two possible situations: one for protections detected
by the stand-by software and one for protections detected by
the main software.
When the TV is in a protection state due to an error detected by
stand-by software (and thus blinking an error)
and
SDM is
activated via short-circuiting the pins on the SSB, the TV starts
up until it reaches the situation just before protection. So, this
is a kind of automatic stepwise start-up. In combination with the
start-up diagrams below, you can see which supplies are
present at a certain moment. Important to know is, that if e.g.
the 3V3 detection fails (and thus error 8 is blinking)
and
the TV
is restarted via SDM, the Stand-by Processor will enable the
3V3, but will not go to protection now. The TV will stay in this
situation until it is reset (Mains/AC Power supply interrupted).
Caution: in case the start up in this mode with a faulty FET
7U08 is done, you can destroy all ICs supplied by the +3V3,
due to over-voltage. It is recommended to measure first the
FET 7U08 on short-circuit before activating SDM via the
service pads.
When the TV is in protection state due to an error detected by
main software (MIPS protection)
and
SDM is activated via
short-cutting the service pads on the SSB, the TV starts up and
ignores the error.
In this chassis, only error “63” (power-ok) is a MIPS protection
and already displays the failure via blinking LED.
The abbreviations “SP” and “MP” in the figures stand for:
•
SP: protection or error detected by the
S
tand-by
P
rocessor.
•
MP: protection or error detected by the MIPS
M
ain
P
rocessor.
Figure 5-3 Transition diagram
H_17650_09
3
.ep
s
1
8
010
8
On
Active
S
emi
S
t by
S
t by
(Off
S
t by)
Off
M
a
in
s
on
M
a
in
s
off
GoToProtection
- W
a
keUp
re
qu
e
s
ted
- Ac
qu
i
s
ition
needed
- No d
a
t
a
Ac
qu
i
s
ition
re
qu
ired
a
nd no POD pre
s
ent
- t
a
ct
S
W p
us
hed
-
S
t
b
y
re
qu
e
s
ted
- t
a
ct
S
W
p
us
hed
W
a
keUp
re
qu
e
s
te
d
Protection
W
a
keUp
re
qu
e
s
te
d
GoToProtection
POD
S
t by
No d
a
t
a
Ac
qu
i
s
ition
re
qu
ired
a
nd
POD pre
s
ent
- POD C
a
rd removed
- t
a
ct
S
W p
us
hed
GoToProtection
- W
a
keUp
re
qu
e
s
ted
- Ac
qu
i
s
ition
needed
For POD
s
ho
u
ld
b
e re
a
d Common Interf
a
ce (CI)