150S4 LCD
41
Go to cover page
Colour adjustment
15. Gray scale checking
- Switch Timing/pattern generator to
Pattern: 32 gray scale
Timing: 1024 X 768 60Hz 48KHz
- Setting both Brightness and Contrast to 50 (Value).
- Check black and white scale are visible clearly across the screen.
See Fig. 1
Fig. 1
Note: The bright scale will be saturated, if Y is too large. The dark scale
will be invisible, if Y is too small. Re-alignment or review procedure
again to correct this.
6500 K
14. Setting X, Y value listed as below:
X= 0.312 0.005
Y= 0.338 0.005
Y>= 250 nits
Alignment hits: 1. R for x value , G for y value, B for Y value on the
colour analyzer.
2. If the colour analyzer has been calibrated and preset
colour temperature in it. Please switch to correct
setting in accordance with colour settings.
0