background image

k

T A N K M O N I T O R   T C M 4

INSTRUCTION MANUAL

philippi elektrische systeme gmbh

www.philippi-online.de

Neckaraue 19

[email protected]

D-71686 Remseck am Neckar

Telefon: +49 (0)7146/8744-0, Fax -22

V2.3 - August 2011

INDEX

1.     

INTRODUCTION..........................................................................................................................................2

2.

SAFETY INSTRUCTIONS ........................................................................................................................... 3

3.

INSTALLATION.............................................................................................................................................4

4.

OPERATION................................................................................................................................................. 5

5.

HANDLING / SETUP.....................................................................................................................................6

6.

TROUBLESHOOTING................................................................................................................................12

7.

MAINTENANCE..........................................................................................................................................12

8.

TECHNICAL DATA......................................................................................................................................12

9.

CE-CONFORMITY...................................................................................................................................... 12

Содержание TCM4

Страница 1: ...i online de Neckaraue 19 info philippi online de D 71686 Remseck am Neckar Telefon 49 0 7146 8744 0 Fax 22 V2 3 August 2011 INDEX 1 INTRODUCTION 2 2 SAFETY INSTRUCTIONS 3 3 INSTALLATION 4 4 OPERATION 5 5 HANDLING SETUP 6 6 TROUBLESHOOTING 12 7 MAINTENANCE 12 8 TECHNICAL DATA 12 9 CE CONFORMITY 12 ...

Страница 2: ... litres is correct because it mea sures the flowed litres If you re using other sensors the TCM calculates the remaining tank capacity by the tank volume and the actual level Depending on the accuracy of the sensors it cannot be litre correct EXTENDED ADJUSTMENT POSSIBILITIES starting from software 2A May 2010 the tank depth can be adjusted to the centimetre by using ultrasonic sensors UTV40 or UT...

Страница 3: ...we cannot accept carriage forward deliveries 1 5 EXCLUSION OF LIABILITY Both the adherence to the operating instruction and the conditions and methods during installation using and maintenance of the TCM cannot be supervised by philippi electrical systems Therefore we do not take any responsibility for loss damage or costs which develop due to incorrect installation and or inappropriate enterprise...

Страница 4: ...passive resistance and active ultrasonic sensors at the same time For the connection have a look at the connection diagramms The flow sensor DFS has to be connected to terminal TG1 if you re using 2 flow sensors DFS terminal TG1 and TG2 If you want to use tank sensors with an output of 4 20mA or 0 10V you need a hardware adaption at our company Please ask The power supply of the TCM is either dire...

Страница 5: ...hreshold is over 50 the full alarm is on i e a filling level over the threshold set off the alarm If the threshold is below 50 the empty alarm is on i e a filling level below the threshold sets off the alarm In case of an alarm the related tank symbol is blinking and a buzzing signal is sounding for the preset time The alarm can be acknowledged by you when pressing a button To reduce the current c...

Страница 6: ...ly if tank1 Tanktype 40 Flow sensor DFS Button 2 Long pressing 3s Tank is being filled up in 5 steps until the maximum value Only if tank1 Tanktype 40 Flow sensor DFS Button 3 Short pressing 2s SETUP menu available when the display is blinking release the button Long pressing 5s Setup menu is locked unlocked Button 4 no function 5 1 SETUP In the SETUP menu all adjustments can be changed Following ...

Страница 7: ...following languages German English French Italian Spanish 5 Contrast Display contrast attitude dimmer brighter 6 Powersave Mode 1 on 0 off The inverted line can be changed ADJUSTMENTS OF THE TANK DISPLAY You get into the choosen tank menu by pressing the button 3 arrow to the right in the tank menu you can adjust the tank type e g water fuel waste and the type of the sensor the capacity the compen...

Страница 8: ...üschelgeber 4 Stufen AuxiliaryhardwarePB43 B 35 36 37 38 39 philippi UTV 40 UTV 80 0 5 2 5V C 40 Flow sensor DFS former tank type 35 4 20mA possible by Hardware adjustment Incorrect display information can occur due to not compatible parts Please ensure that the tank type matches the sensor In former models the tank type of the flow sensor DFS was 35 A FREE ADJUSTMENT OF THE RESISTANCE RANGE OF TH...

Страница 9: ... tank greater than 40 cm you have to use an UTV80 The TCM4 is showing that automatically To balance the off zone of the ultrasonic sensor the range which is not measurable between sensor and liquid surface 50 mm you can use a distance ring UTS 25 or UTS 50 If you re using such a distance ring you can entry this distance too If the tank depth plus the distance ring is equal or less than 40 cm you n...

Страница 10: ...01 s Alarm open end until it will be acknowlegded by pressing a button or if the measured value has changed so that the alarm is cancelled Alarm level 0 Alarm off 1 50 Empty alarm if the level falls below the adjusted threshold the alarm will be activated The activation is delayed by 15s 51 99 Full alarm if the level rises above the adjusted threshold the alarm will be activated The activation is ...

Страница 11: ...is can be considered in the display The compensation value changes the tank characteristic in such a way that the indicated level is approximated to geometry of the tank The value to be entered is value the tank display should indicate with the half level height of the tank is The following examples shows which values the compensation value with different geometry will be If tank geometry is stron...

Страница 12: ... DATA Power supply DC 10 30 Volt Power consumption ca 8mA when using resistance sensors 60mA if the display is lit 12V 12mA when using a flow sensor DFS when using ultrasonic sensors UTV 50 mA per sensor without Powersave mode Dimensions 105 x 105 x 40 mm Installation cutout 88 x 88 mm 9 CE CONFORMITY philippi elektrische systeme gmbh Neckaraue 19 71686 Remseck am Neckar Germany certifies herewith...