Manual EM-box 3
Hardware 3.1 - REV 3B - JAN 20
Page 9
2.9 Loads
If more than 2 high current consumers are to be connected directly to the EM-box, an external bolt fuse distributor
(e.g. BlueSea 5196) is connected to the connection (+6). The positive connection (+6) is thus extended for additional
loads. On the minus side, a negative busbar can be used to simplify the installation.
Note: Only the total current can be displayed for the loads at a common connection
2.10
Engine with 2- or 3- wire connection
To connect the engine to the EM-box, the internal positive connection cable between the alternator and the starter
motor should be removed, so that the starter cable (+) can be connected separately from the alternator output (+). In
this case the connection is made according to the left picture, as in all the connection diagrams already shown. If the
separation of the internal positive connection line between the alternator and the starter motor is not possible, the
motor is connected according to the "2 wire" configuration, as shown in the right picture.
„3 wire“-configuration
„2 wire“-configuration