Phenix Technologies KVM300 Скачать руководство пользователя страница 1

KVM300 

 

 

 
 
 
 
 
 
 
 
 
 
 

AC KILOVOLTMETER 

 

MODEL NO.  KVM300 

 

VERSION 2.1 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 Copyright © Phenix Technologies, Inc. 

 
 
 
 
 
 

JPG/SLU 
MAY, 2008 
REV 9/4/’14 nab 

Содержание KVM300

Страница 1: ...KVM300 AC KILOVOLTMETER MODEL NO KVM300 VERSION 2 1 Copyright Phenix Technologies Inc JPG SLU MAY 2008 REV 9 4 14 nab...

Страница 2: ...ECTRICAL SET UP OPERATIONAL NOTES 4 OPERATING INSTRUCTIONS 5 CALIBRATION 6 MECHANICAL MAINTENANCE 7 STORAGE OF EQUIPMENT 8 TROUBLESHOOTING 9 RECOMMENDED SPARE PARTS 10 PARTS ORDERING INFORMATION 11 RE...

Страница 3: ...KVM300 1 1 SECTION 1 DANGER WARNINGS WARNING Complete Grounding of this unit is necessary for the safe operation of this equipment Disconnect inputs before ungrounding this equipment...

Страница 4: ...h Voltage Test Equipment have been listed below for your reference Become familiar with your instrument before performing an actual test Know your work area check that all circuits are de energized an...

Страница 5: ...try Display is 4 Digit LED with adjustable backlighting ACCURACY 1 of Reading 3 counts from 10 100 of Range FUNCTION SELECTIONS 1 Peak 2 Peak responding calibrated to RMS Value 2 Peak Peak responding...

Страница 6: ...round 6 BNC INPUT CONNECTOR This BNC input connector connects the meter module to the divider 7 BACKLIGHT DIMMER This dial adjusts the intensity of the backlight for use during low light conditions 8...

Страница 7: ...inspection to determine if the unit was damaged in shipment If there are any signs of physical damage such as dents scratches or oil leaks contact the factory before proceeding NOTE Read and understa...

Страница 8: ...will affect the AC calibration CAUTION The meter module has to be grounded for safe and proper operation Connect the ground post on the metering module to an appropriate ground A 10 lead is supplied...

Страница 9: ...sure voltage as required Meter low range should not be used past 30kV Meter may not be accurate past 100 of reading and actual voltage may be much higher than indicated De activate high voltage source...

Страница 10: ...and 1 M 200pF AC for the highest possible accuracy Readings will correspond to the type of meter used AVG will show AVG RMS will show RMS etc Use DC range for DC signals 10M input meter Select desire...

Страница 11: ...TION SHOULD ONLY BE DONE BY PERSONS FAMILIAR WITH HIGH VOLTAGE TESTING AND SAFETY PROCEDURES CALIBRATION PROCEDURES Due to the complexity and the standards required to calibrate this instrument Phenix...

Страница 12: ...ainst the elements in normal use It is recommended that the finish be wiped down with an ordinary household cleaner for longer life and for proper electrical operation of the unit Also inspect all fab...

Страница 13: ...olonged period the following precautions are recommended The equipment should be covered and kept in a warm dry environment 95 maximum humidity 5 to 50 degrees C Prior to placing the equipment back in...

Страница 14: ...g testing because of transient discharge occurrence and won t come back on by cycling the power switch Carefully remove front panel and unplug the battery pack for approximately 30 seconds then retry...

Страница 15: ...r quantity of parts should be stocked as spares In such a case contact your Phenix Technologies sales representative for a recommendation Current prices may be obtained by contacting the Parts Orderin...

Страница 16: ...important when ordering parts to include the serial number of the unit as well as the part number of the replacement part When your purchase order is received at our office a representative of Phenix...

Страница 17: ...er Reason for Return Cause of Defect If Phenix Technologies Inc deems return of the part appropriate it will then issue an Authorization for Return If return is not deemed advisable other inspection a...

Страница 18: ...D TR M K K K TB X Intensite Diode Transisteur Thyristor Borne Ouvert Ferme Contact de SYMBOLE ZU SCHEMA SYMBOLES POUR SCHEMA DE CIRCUIT CIRCUIT DIAGRAM SYMBOLS Variable Resisitor Resistor Lamp Indica...

Страница 19: ...KVM300 14 1 SECTION 14 SCHEMATICS AND DRAWINGS Drawing Number Description 1 7916004 KVM300 SCHEMATIC...

Страница 20: ...or s Manual are correct If there are concerns or comments as you have used this information Phenix Technologies appreciates any feedback Unit Serial Number Sect Page s Comment Please return to Phenix...

Отзывы: