Alarm messages
Alarm
Description
Err
or - an incorrect key has been pressed
A
larm
H
igh
T
emperature - temperature is above the high temp
alarm setting
A
larm
L
ow
T
emperature - temperature is below the low temp
alarm setting
A
larm
L
ow
P
ower - the line voltage is low
A
larm
P
robe
D
isconnect - the temperature sensor is
disconnected
A
larm
P
robe
S
hort - The temperature sensor is short circuited
A
larm
P
ower
F
ailure - the power has been interrupted
A
larm
I
nternal
E
rror - indicates an internal error has occurred
V
entilation
Off
- ventilation has been turned off in the program
Reasons for alarms to activate
The Err message appears when an incorrect key has been pressed or if an attempt has
been made to change a parameter while memory protect is on. The Err message will
appear for 2 seconds and then disappear.
The high temperature alarm appears when the room temperature is above the high
temperature alarm setting (parameter #13). Check if the fans are operating properly. This
alarm may occur on very hot days when the desired room temperature can not be
maintained.
The low temperature alarm appears when the room temperature is below the low
temperature alarm setting (parameter #12). Check if the heater is operating properly.