Configuring relays for inlet actuators or curtains
Inlets, curtains, and similar equipment are opened and closed to let in more air or less air. The idea is that
more air cools the building. There are two types of inlets: inlets with feedback and inlets without feedback.
Each requires one relay for opening and one for closing.
Inlets with feedback
The relays control a motor that opens and closes and requires feedback to know its position. An example is
an actuator. You can configure up to two inlets that require feedback.
Inlets without feedback
The relays control a motor that opens and closes, but does not require feedback. An example is a curtain
machine or winch. You can configure up to six inlets that do not require feedback.
on page 84 when configuring relays.
To configure relays for inlets
1.
Press the
Menu
and then
Configuration
.
2.
Press
Equipment
.
3.
Press
Inlets
.
4.
Press the inlet you want to configure.
The Equipment Configuration screen displays.
Name:
a)
Press the button beside Name and then press
Rename
.
b)
Press
Reset
and then type the new name.
c)
When finished, press
Confirm
to save the name and return to the previous screen.
Name
Function
Zone