Configuring equipment
Configuring variable stages
The Supra Touch has four variable AC stages (
VAR 1
to
VAC 4
) to control equipment using gradually
increasing or decreasing voltage. Variable stages can be cooling or heating.
Cooling
: the stage controls cooling equipment, such as a variable speed fan.
Heating
: the stage controls heating equipment, such as a heat lamp.
To configure variable stages
1.
Press the
Menu
and then
Configuration
.
2.
Press
Equipment
.
3.
Press
VACs
.
4.
Press the variable stage you want to configure.
The Equipment Configuration screen displays.
Name:
a)
Press the button beside Name and then press
Rename
.
b)
Press
Reset
and then type the new name.
c)
When finished, press
Confirm
to save the name and return to the previous screen.
Function:
Press the button beside Function and then choose the equipment type. If you choose cooling,
motor curve and de-icing options become available.
Motor curve:
The default is motor curve 1. Change the motor curve
only if you need to
. Read
Motor curves
92 before changing the motor curve.
To change the curve, press the button and then select one of the other ones.
De-icing:
To enable de-icing, press the checkbox beside it. Press the Up or Down arrows to adjust the setting.
Zone:
Press the button beside Zone and then choose the one the equipment will operate in.
5.
Press
Save
when you are finished.
Name
Function
Zone