![PFU Limited fi-6130 Скачать руководство пользователя страница 175](http://html1.mh-extra.com/html/pfu-limited/fi-6130/fi-6130_maintenance-manual_1535731175.webp)
08
July 27, 09 K.Okada
A.Miyoshi I.Fujioka
Refer to Revision Record on page 2.
TITLE
fi-6140/fi-6240/fi-6130/fi-6230/fi-614PR
Maintenance Manual
07
Nov.12, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
CUST.
06
Mar.10, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
DRAW
No.
P1PA03540-B0XX/6
Rev. DATE DESIGN CHECK APPR. DESCRIPTION
Design
July 27, 2007
K.Okada
CHECK
K.Okada
APPR.
T.Anzai
PFU LIMITED
Page
175
/
257
Section 6-2
6-2 Saving EEPROM data
The EEPROM data on the Panel PCA can be saved on the flash memory of the Control PCA. This operation is necessary before
replacing the Panel PCA. Since this operation is taken when the Panel PCA is malfunctioning, save data by following the
procedure below without using the operator panel.
- Do not conduct this procedure unless the Panel PCA is malfunctioning.
- The Panel PCA from which the data was saved to the Control PCA cannot be used again. (See
NOTICE on the next page.)
- Make sure to prepare a new Panel PCA before saving the EEPROM data.
[How to save EEPROM data on the Control PCA]
1.
Open the ADF cover. While pressing the TOP sensor (circle below) (=ON) and lifting up the Empty sensor (Sensor EMP)
(=OFF), power on the scanner.
“P”
Æ
“ H ” are displayed if the Function Number display is working correctly.
Note: Lifting up the Empty sensor with a screwdriver makes the operation easier.
PICK sensor
ADF Cover
TOP sensor
US sensor
US sensor
Empty sensor
(Sensor EMP)
Paper protection roller
(fi-6140/fi-6240 only)
Lift up the Empty
sensor with a
screwdriver.
Screwdriver
03