Страница 1: ...OPERATING INSTRUCTIONS EN Translation of the Original WEB UI User interface for the QMG 250 PrismaPro ...
Страница 2: ...o pfeiffer vacuum de Further operating instructions from Pfeiffer Vacuum can be found in the Download Center on our website Disclaimer of liability These operating instructions describe all models and variants of your product Note that your product may not be equipped with all features described in this document Pfeiffer Vacuum constantly adapts its products to the latest state of the art without ...
Страница 3: ...ismaPro Web UI 14 5 1 STATUS window 14 5 2 MONITOR window 15 5 3 LEAKCHECK window 16 5 4 DIAGNOSTICS window 18 5 5 PRINT window 19 5 6 HELP window 19 6 Using PrismaPro Web UI 20 6 1 Using PrismaPro Web UI and PV MassSpec 20 6 2 Using PrismaPro Web UI in stand alone mode 20 6 2 1 Collecting data 21 6 2 2 Modifiable parameters 21 6 2 3 Carrying out a leak test 23 6 2 4 Setting the status parameters ...
Страница 4: ... Analyzer QMA 250 7 Tbl 4 Electronic unit QME 250 7 Tbl 5 Abbreviations used 8 Tbl 6 Minimum computer requirements 11 Tbl 7 Parameters in the STATUS window 14 Tbl 8 Default monitor parameters 21 Tbl 9 Modifiable parameters 22 Tbl 10 Default parameters 23 List of tables 4 30 ...
Страница 5: ...indow 19 Fig 8 Access by PV MassSpec 20 Fig 9 Access by PV MassSpec 20 Fig 10 Access by PV MassSpec leak check message 20 Fig 11 EMISSION switch in the MONITOR and LEAKCHECK windows 22 Fig 12 Three colors of the EMISSION indicator 22 Fig 13 EM switch in the MONITOR and LEAKCHECK windows 22 Fig 14 EM off and on 22 Fig 15 Scan parameters in the MONITOR window 23 Fig 16 Status parameters 24 Fig 17 No...
Страница 6: ...ocumentation PV MassSpec Part of the software Tbl 1 Related documents Current documents are available from the Pfeiffer Vacuum Download Center 1 1 2 Variants This document applies to products with the following part numbers Part number Designation PT M15 QMG 250 PrismaPro Faraday PT M16 QMG 250 PrismaPro Faraday electron multiplier Tbl 2 QMG 250 PrismaPro Part number Short description Mass range u...
Страница 7: ...to scale Dimensions are in mm unless stated otherwise 1 2 Target group These operating instructions are aimed at all persons performing the following activities on the product Transportation Setup Installation Usage and operation Decommissioning Maintenance and cleaning Storage or disposal The work described in this document is only permitted to be performed by persons with the appropriate technic...
Страница 8: ...al pending danger Indicates a pending danger that could result in minor injuries if not observed Instructions to avoid the danger situation NOTICE Danger of damage to property Is used to highlight actions that are not associated with personal injury Instructions to avoid damage to property Notes tips or examples indicate important information about the product or about this docu ment 1 3 4 Abbrevi...
Страница 9: ...plorer are trademarks of Microsoft Corporation Firefox is a trademark of Mozilla Foundation Chrome and Android are trademarks of Google Inc Opera is a trademark of Opera Software AS Safari iPhone and iPad are trademarks of Apple Inc Galaxy is a trademark of Samsung About this manual 9 30 ...
Страница 10: ...ro provides a diagnostic window that shows the unit status and any errors You should use the PrismaPro Web UI in parallel to PV MassSpec PrismaPro Web UI does not allow data storage PrismaPro Web UI is a remote monitoring and diagnostic tool and is designed for data monitoring and simple vacuum diagnostics The storage of data or display of data in a trend graph is not possible with PrismaPro Web U...
Страница 11: ...sor Pentium 4 1 8 GHz or higher Random access memory RAM 1 GB or higher Resolution 1024 x 768 16 bit color or higher Operating system Windows 7 Windows 8 Windows 10 Windows Vis ta Windows XP Connection Ethernet PrismaPro Web UI itself has no operating system requirements The requirements depend on the browser used For Windows XP Pfeiffer Vacuum recommends using Mozilla Firefox or Google Chrome as ...
Страница 12: ...he browser with an IP address on this network e g 192 168 1 101 1 Type the default IP address 192 168 1 100 into the browser address bar 2 Press Enter The browser connects to the PrismaPro If the PrismaPro is switched on and connected to the same network as the computer the STATUS window appears in the PrismaPro Web UI 3 If the STATUS window does not appear Refresh the browser 4 If the STATUS wind...
Страница 13: ... Enter The browser connects to the PrismaPro If the PrismaPro is switched on and connected to the same network as the device the STATUS window appears in the PrismaPro Web UI 3 If the STATUS window does not appear Refresh the browser 4 If the STATUS window still does not appear proceed as follows 5 Make sure that you have not connected any other devices to the PrismaPro Web UI 6 Refresh the browse...
Страница 14: ...connected electronics IP ADDRESS IP address of the connected PrismaPro The PrismaPro has a default IP address of 192 168 1 100 SUBNET MASK Subnet mask of the connected PrismaPro The PrismaPro has a default subnet mask of 255 255 0 0 GATEWAY Gateway of the connected PrismaPro The PrismaPro has a default gateway of 0 0 0 0 DHCP ENABLED Specifies whether DHCP is ON or OFF default MAC ADDRESS MAC addr...
Страница 15: ...quisition window The right side of the MONITOR window contains a group of editable fields Scan parameters EMISSION switch for emission control EM switch for electron multiplier control The EM field shows the electron multiplier voltage in volts V Navigating around the PrismaPro Web UI 15 30 ...
Страница 16: ...PrismaPro see chapter Carrying out a leak test page 23 It uses the PrismaPro signal level to generate alarm states When you open the window for the first time the PrismaPro Web UI generates alarm levels automati cally based on the current mass signal Navigating around the PrismaPro Web UI 16 30 ...
Страница 17: ... switch both the emission and electron multiplier where present on and off Display of measured values against time The mass trend graph indicates how the signal in amperes changes over time for the specified mass The trend diagram has two lines one yellow and one red These lines represent the warning and alarm levels If the signal rises above these alarm level lines a leak is present Bar graph dis...
Страница 18: ...colors 5 4 DIAGNOSTICS window The DIAGNOSTICS window indicates the system status and contains additional diagnostic capabili ties that can be helpful when contacting Pfeiffer Vacuum Navigating around the PrismaPro Web UI 18 30 ...
Страница 19: ...RINT allows you to call up a print dialog box to print the displayed window 5 6 HELP window HELP lets you open the PrismaPro Web UI operating manual and the Quick Start Guide in a separate browser tab Navigating around the PrismaPro Web UI 19 30 ...
Страница 20: ...for the PrismaPro Analyzer PV MassSpec gives control of the PrismaPro analyzer to PrismaPro Web UI only if you have stopped data acquisition or when waiting for data acquisition to start Fig 8 Access by PV MassSpec Fig 9 Access by PV MassSpec Fig 10 Access by PV MassSpec leak check message 6 2 Using PrismaPro Web UI in stand alone mode This section contains instructions for using PrismaPro Web UI ...
Страница 21: ... and EM are the only settings with direct influence on data acquisition if you modify them You can modify the other scan parameters however they only influence data acquisition if you click SET Modifiable parameter Description Emission On Off Switches the filament in the PrismaPro ion source on or off You must have switched on Emission for data acquisition to be able to switch on the electron mult...
Страница 22: ...utton This indicator changes color according to the emission state There are 3 colors black Emission off yellow Warm up phase green Emission on Fig 11 EMISSION switch in the MONITOR and LEAKCHECK windows OFF WARMING UP ON Fig 12 Three colors of the EMISSION indicator Switching EMISSION on and off In the MONITOR or LEAKCHECK window click on the EMISSION button to switch emission on or off Switching...
Страница 23: ...entration detecting leaks by displaying increased nitrogen oxygen and carbon dioxide concentrations The SET buttons are mutually independent The SET buttons in the LEAKCHECK window for the alarm levels and scan parameters are mutually independent and neither sets the parameters of the other area Direct influence on data acquisition Emission and EM are the only settings with direct influence on dat...
Страница 24: ...at the signals generated by the PrismaPro are normal and appear green for the alarm level 7 Switch on the emission You must switch on the emission to carry out leak detection 8 Switch on the electron multiplier where present 9 Spray the test gas around the area under investigation while monitoring changes in the display of mass against time and the bar graph display 10 If a leak is present the sof...
Страница 25: ... PrismaPro restarts automatically and then uses the new IP address Subnet mask Changing the PrismaPro subnet mask The PrismaPro has a default subnet mask of 255 255 0 0 The PrismaPro subnet mask must match the subnet mask of the computer network on which you have installed PrismaPro 1 Connect the PrismaPro to a computer with a subnet mask of 255 255 0 0 2 Open PrismaPro Web UI 3 Open the STATUS wi...
Страница 26: ...ort 80 2 Open PrismaPro Web UI 3 Open the STATUS window 4 Delete the current port number in the SETTINGS group and enter the new port number 5 Click on SET 6 Restart the PrismaPro After the restart the PrismaPro communicates via the new port number and is connected to the network 6 3 Desktop shortcuts As PrismaPro Web UI is browser based you can create desktop shortcuts to open the browser directl...
Страница 27: ...ortcuts you can also create bookmarks within your Internet browser Adding browser bookmarks 1 In the browser press CTRL D on the desired page 2 Name the bookmark so that you can distinguish between different functions and sensors Using PrismaPro Web UI 27 30 ...
Страница 28: ...open the MONITOR window for the first time peaks at 28 u nitrogen 32 u oxygen and 44 u carbon dioxide indicate that an air leak outward leak to atmosphere is present Using the LEAKCHECK menu it is then very easy to locate the position of the leak Starting at the top you must then briefly and slowly spray helium onto the seals and other vacant posi tions that could be the source of the leak and mon...
Страница 29: ... 24 V DC voltage supply If this is the case try resetting the current supply 4 Make sure that the Ethernet cable is connected to the PrismaPro and the network 5 Clear the browser cache You can find instructions on how to do this in your browser help files 6 If these steps do not solve the issue connect the PrismaPro directly to your computer bypass ing the router network and try to connect the dev...
Страница 30: ... BG6002 ed D Date 2008 P N BG6002BEN ...