14.3 Technical data
Classification
Duo 11 ATEX
ATEX-certification
II 3/3G Ex h IIC T4 Gc X
Part number
PK D59 905
Connection flange (in)
DN 16 ISO-KF
Connection flange (out)
DN 16 ISO-KF
Pumping speed at 50 Hz
9 m³/h
Pumping speed at 60 Hz
10.5 m³/h
Final pressure with gas ballast
3 · 10
-2
hPa
Final pressure without gas ballast
3 · 10
-3
hPa
Continuous inlet pressure, max.
50 hPa
Continuous gas temperature, max.
40 °C
Exhaust pressure, max.
1500 hPa
Exhaust pressure, min.
250 hPa
Gas ballast
Yes
Gas ballast pressure
≤ 1200 hPa
Water vapor capacity 50 Hz
65 g/h
Water vapor capacity 60 Hz
84 g/h
Water vapor tolerance at 50 Hz
10 hPa
Water vapor tolerance at 60 Hz
11 hPa
Emission sound pressure level without gas ballast at 50 Hz
54 dB(A)
Cooling method, standard
Air
Motor version
3-ph motor
Input voltage 50 Hz
230 / 400 V
Input voltage 60 Hz
265 / 460 V
Input voltage: tolerance
±5 %
Rated power 50 Hz
0.25 kW
Rated power 60 Hz
0.3 kW
Rotation speed at 50 Hz
3000 rpm
Rotation speed at 60 Hz
3600 rpm
Protection category
IP66
Motor protection
PTC
Mains cable included
No
Switch
No
Magnetic coupling
Yes
Leak rate
≤ 1 · 10
-8
Pa m³/s
Leak rate safety valve
≤ 1 · 10
-5
Pa m³/s
Operating fluid amount
0.5 l
Operating fluid
P3
Ambient temperature
12 – 40 °C
Shipping and storage temperature
-10 – 40 °C
Weight
15.3 kg
Tbl. 17:
Technical data Duo 11 ATEX
14.4 Dimensions
Dimensions in [mm]
Technical data and dimensions
55/58