5.2 Electrical connection
➢
Installation:
➢
Loosen the four cross-head screws in the lens and remove them upwards.
➢
The holes for mounting the housing are then accessible, for dimensions see chapter
Alter-
native installation possible with the brackets supplied.
➢
Perform electrical connection on the circuit board in the lens as follows:
115
– 230 V AC/ 115 – 230 V DC
S1,
Selection of operating mode
S1
Operating
mode no.
1
2
3
OFF OFF OFF
1
Flashing light 0.75 Hz
OFF OFF ON
2
Flashing light 1 Hz
OFF ON OFF
3
Continuous light
OFF ON ON
4
Blinking light 1 Hz
ON OFF OFF
5
Flashing light 2 Hz
ON OFF ON
6
Blinking light 2 Hz
ON ON OFF
7
Flashing light 0.1 Hz
ON ON ON
8
Flashing light 0.5 Hz
X1
Operating voltage
connection
AC:
DC:
Connection of
the line
Light intensity
control
(15 - 100%)
DC version (12
– 48 V)
X1
Operating voltage
connection
Connection
of the line
X2
External control in-
put
S1
Selection of
operating mode
Light intensity control
(15 - 100%)
Note:
Devices with DC voltage are equipped with reverse polarity protection. The function is guaranteed if the
polarity of the connections is reversed.
➢
Only cable glands with a degree of protection of at least IP66/ IP67 should be fitted to the corresponding
openings.
➢
Secure the connecting cables against pulling and twisting during installation.
➢
Close the device again after connecting the cables.
➢
Carry out a final functional test to ensure reliable signaling.