5. Approvals

(Approvals are valid for marked devices) 

DNV GL 

TAA00001R1   

EAC 

6. Commissioning

6.1   Safety information 

DANGER

 

- Danger to life due to electric shock 

Voltage-carrying devices and exposed connection cables may cause electric shocks and serious 
accidents. 

  Only trained and authorized electricians may work on electrical connections. 

  Disconnect all supply lines from mains before installation and secure them against reconnec-

tion. Always ensure absence of voltage. 

  Wait for the discharge phase of 15 minutes for the electrical components. The unit should only 

be opened afterwards. 

  The operating voltage must only be applied when the housing is firmly closed. 

WARNING - Danger due to unauthorized use of the devices 

Improper use may lead to serious accidents.  

  Ensure that the connection cable is protected against pulling and twisting during installation. 

The devices are only intended for fixed installation. 

DANGER - Danger due to damage to the devices 
Non-compliance with the information on the type plate can lead to serious accidents. 

  Always observe the information on the type plate when installing and maintaining the units. 

CAUTION - Risk of injury due to sharp edges or heated components 

  Wear gloves during any installation, assembly or service/maintenance work.  

  Perform wiring tasks at a distance from sharp edges, corners and internal components. 

CAUTION - Risk of sight impairment 

 

Avoid constant, direct glances into the activated lights to prevent impairment of vision. 

Opening/ Closing the housing 

Circuit 

board 

The housing can be lifted up and off by loosening the two Phillips screws at the sides. 

Содержание ABL

Страница 1: ...die optische Signalisierung von z B Gefahrzust nden in Industrie Gewerbe und Geb udebereichen bestimmt Die Blitzleuchten mit integrierter berwachungsfunktion WBL WBS verf gen ber einen potentialfreie...

Страница 2: ...dauer 100 Anschlussklemmen PE Anschluss eindr htig feindr htig 0 5 2 5 mm2 feindr htig mit Aderendh lse DIN 46228 1 0 5 1 5mm2 Schutzart IP 54 EN 60529 vertikale Montage Schutzklasse I Betriebstempera...

Страница 3: ...essungsstrom aufnahme 260 mA 350 mA 700 mA 1500 mA WBL WBS Bemessungs spannung 230 V AC 115 V AC 42 V AC 24 V DC 12 V DC Arbeitsspannungs bereich 185 242 V 90 135 V 37 47 V 18 35 V 10 15 V Bemessungs...

Страница 4: ...unzul ssigen Einsatz der Ger te Der nicht bestimmungsgem e Einsatz kann zu schweren Unf llen f hren Bei der Installation darauf achten dass die Anschlussleitung gegen Zug und Verdrehen abge sichert i...

Страница 5: ...hluss X2 Alarmausgang X2 Alarmausgang Das Schaltverm gen der Auswerteelektronik betr gt 230V 2A Hinweis Ger te mit DC Spannung sind mit einem Verpolungsschutz ausger stet Keine Funktion bei Verpolung...

Страница 6: ...ich nur im Herstellerwerk ausf hren lassen Umbauten nderungen fehlerhafter und unzul ssiger Einsatz sowie die Nichtbeachtung der Hinweise dieser Betriebsanleitung schlie en eine Gew hrleistung aus 9 A...

Страница 7: ...ies are designed for the optical signaling of e g hazardous conditions in industry trade and construction areas The flashing lights with integrated monitoring function WBL WBS have a potential free sw...

Страница 8: ...terminals PE connection solid fine stranded 0 5 2 5 mm2 fine stranded with wire end ferrule DIN 46228 1 0 5 1 5 mm2 Ingress protection IP 54 EN 60529 vertical assembly Protection class I Operating tem...

Страница 9: ...urrent con sumption 260 mA 350 mA 700 mA 1500 mA WBL WBS Rated operating voltage 230 V AC 115 V AC 42 V AC 24 V DC 12 V DC Operation voltage range 185 242 V 90 135 V 37 47 V 18 35 V 10 15 V Rated freq...

Страница 10: ...WARNING Danger due to unauthorized use of the devices Improper use may lead to serious accidents Ensure that the connection cable is protected against pulling and twisting during installation The dev...

Страница 11: ...ting voltage connection X2 Alarm output X2 Alarm output The switching capacity of the electronic evaluation unit is 230V 2A Note Devices with DC voltage are equipped with reverse polarity protection N...

Страница 12: ...the manufacturer s premises Conversions modifications improper and impermissible use as well as failure to observe the notes in this op erating instructions shall void any warranty 9 Decommissioning d...

Страница 13: ...la signalisation optique des situations dangereuses dans l industrie le commerce et le secteur du b timent par exemple Les feux flash avec fonction de surveillance int gr e WBL WBS sont munis d un co...

Страница 14: ...0 Bornes de connexion Liaison PE unifilaire fil fin 0 5 2 5 mm2 fil fin avec embout DIN 46228 1 0 5 1 5 mm2 Indice de protection IP 54 EN 60529 montage vertical Classe de protection I Temp rature de s...

Страница 15: ...on de courant assign e 260 mA 350 mA 700 mA 1500 mA WBL WBS Tension assign e 230 V CA 115 V CA 42 V CA 24 V CC 12 V CC Plage de tensions de service 185 242 V 90 135 V 37 47 V 18 35 V 10 15 V Fr quence...

Страница 16: ...sque li une utilisation non conforme des appareils Une utilisation non conforme peut entra ner des accidents graves Lors de l installation s assurer que le c ble de raccordement est prot g contre la t...

Страница 17: ...e la tension de service X2 Sortie de l alarme X2 Sortie de l alarme La puissance de coupure de l lectronique de contr le s l ve 230V 2A Remarque Les appareils tension continue CC sont dot s d une prot...

Страница 18: ...tre effectu es dans les ateliers du fabricant Toute transformation modification utilisation incorrecte ou interdite ainsi que le non respect des instructions de service entra nent une exclusion de ga...

Отзывы: