background image

DE

NL

IT

FR

ES

EN

 

www.petsafe.net 7

6 www.petsafe.net

Timer Mode example:

 It might be helpful to think of Timer Mode in the form of a 24 hour or clock timeline  If you want your pet(s) to have full 

access during the daytime (for example, from 7 am in the morning until the late evening) but want your pet(s) to be indoors at night (for example, 
starting at 7 pm), you would want to set the access mode to 

In/Out

 at 7 am and then the access mode to 

In-Only

 at 7 pm  

To Remove Timer Mode Access Time:

1   From 

Main Menu

 select 

Setup > Pet Settings > Master Access > Mode

 

2   Press right arrow key to scroll to Timer option to select  
3   Once Timer has been selected, Access Time will appear at bottom of 

Master Access Menu list  Use down arrow key to highlight 

Access 

Time

 then right arrow key to select 

4   Use up and down arrow keys to highlight which Access Time slot you 

wish to remove  Press right arrow key to select 

5   Use down arrow key to highlight 

Remove

 and right arrow key to 

select  The time slot on the Access Time Menu should now be removed  

Remember you must have a minimum of two programmed 

Access Times for Timer Mode to work

 

Note:

 Timer Mode can be disabled by setting a different Master Access Mode, while keeping the programmed Timer Mode Settings  This might be 

useful if you want to use Timer Mode during the week and a different Master Access Mode on the weekend  

Re-latch Time (Master Access)

The Re-latch Time is the amount of time it takes the Cat Flap to re-lock after the cat’s microchip/Passport

 Key is no longer detected  Under Master 

Access the same Re-latch Time is easily set for all pets  The factory default Re-latch Time is set to 2 seconds but can be changed from 1 second to 
60 seconds  A longer Re-latch Time may be needed if you have older or slower pets 

To Change Re-latch Time:

1   From 

Main Menu

 select 

Setup > Pet Settings > Master Access

  Use right arrow key to select 

2   Use down arrow key to highlight 

Re-latch Time

 then use right arrow key to scroll through to find desired 

Re-latch Time  Press left arrow/back key to return to Main Menu 

After using Timer Mode to program the example 
listed, the Access Time menu screen would display:

example:

In-Only
In/Out

12 am

7 am

12 pm

7 pm

11 pm

Содержание Passport PPA19-20558

Страница 1: ...resente guida dopo il manuale di installazione Lesen Sie die Gebrauchsanleitung vollständig nach der Montageanleitung Operating Guide Manuel d utilisation Gebruiksaanwijzing Manual de adiestramiento Guida all uso Betriebsanleitung 1000 Series Série Serie Serie Serie Serie Passport Intelligent Cat Flap Passport Chatière intelligente pour chat Passport intelligent kattenluik Puerta inteligente para ...

Страница 2: ... Out Tone Master Access 8 Add Pet 8 INDIVIDUAL PET SETTINGS 8 Pet Access Individual Pet 9 Pet Access Mode Individual Pet 9 Timer Mode Individual Pet 10 Re latch Time Individual Pet 1 1 In Tone Out Tone Individual Pet 1 1 Rename Pet 1 1 Relearn Pet 12 Remove Pet 12 Pet Tracking 12 ASSISTANCE 13 Indicator Light 13 Firmware Updates 13 About 13 Serial Number 13 Troubleshooting 14 Reset Button 15 Repla...

Страница 3: ...in Menu select Setup Door Settings The Door Settings screen displays the following options Door Allows Cat Flap operational mode to be changed with three mode options Smart Mode default factory setting Open or Locked Lock Keypad Allows the 5 Button Navigation to be disabled by setting a 4 digit PIN number Volume Turns the Volume on or off for the audible beeps and sounds such as In Tone and Out To...

Страница 4: ...ons If incorrect PIN number is entered the keypad will remain locked If you cannot remember your PIN number contact our Customer Care Centre Volume Control The Cat Flap has several optional audible alerts such as Low Battery Mode In Tone and Out Tone The Volume for these audible alerts can be turned off or on The default factory setting for Volume is On To Change Volume 1 From Main Menu select Set...

Страница 5: ...ess option and settings for all pets with the Master Access option or to set access and custom settings by individual pet within the Pet Settings menu To open the Pet Settings menu from the Main Menu select Setup Pet Settings The Pet Settings screen displays the following options Master Access Easily allows the same pet access mode and pet settings to be set for all pets This is the default factor...

Страница 6: ...ut Only at specific times of day for all programmed pets This is useful if you want your pets to have a certain access during a specific time period for example at night There are four programmable time slots available with a minimum of two programmed times required The two times are required to prevent your pet from accidentally being locked out or in To Set Timer Mode 1 From Main Menu select Set...

Страница 7: ...u should now be removed Remember you must have a minimum of two programmed Access Times for Timer Mode to work Note Timer Mode can be disabled by setting a different Master Access Mode while keeping the programmed Timer Mode Settings This might be useful if you want to use Timer Mode during the week and a different Master Access Mode on the weekend Re latch Time Master Access The Re latch Time is ...

Страница 8: ...ogram during the 30 second countdown 3 When your cat s microchip is successfully programmed you will hear three beeps and the rename pet text screen will appear Pet X with X being the next available pet number will be listed at the bottom of the screen You can leave the Pet Name as the default or you can rename the pet 4 To rename pet use arrow keys on 5 Button Navigation to scroll through text en...

Страница 9: ...ailable If Master mode is selected as the individual pet access mode then the individual Out Tone cannot be adjusted Pet Access Mode Individual Pet The Access Mode can be programmed for each individual pet This allows you to customise access based on each of your pet s needs The Access Mode options available are Master Under each individual pet when Master mode is selected the pet will be programm...

Страница 10: ... to highlight Time Press right arrow key to enter specific time for your pet to have type of access you just selected in Step 5 After you use arrow keys to enter desired time press enter key to accept Press left arrow back key to return to Access Time menu screen 7 Use down arrow key to highlight second time slot Press right arrow key to select Repeat Steps 5 6 to select pet access mode and schedu...

Страница 11: ...Press down arrow key to highlight Re latch Time then use right arrow key to scroll through to find desired Re latch Time Press left arrow back key to return to Main Menu In Tone Out Tone Individual Pet Optional audible alerts can also be set by pet to let you know when a pet enters or exits with the In Tone and Out Tone settings The default factory setting for both In Tone and Out Tone is Off but ...

Страница 12: ...ase make sure you want to remove a pet before completing these steps To Remove Pet 1 From Main Menu select Setup Pet Settings Pet X or pet s name Remove Pet 2 A confirmation screen will appear Use up arrow key to highlight Yes and press right arrow key to remove pet Pet Tracking To easily know if your pet is in or out the Main Menu screen shows at a glance the current location of each pet programm...

Страница 13: ...r in Installation Guide New versions may be released periodically to make improvements or enhancements to the Cat Flap similar to a mobile phone without the need to purchase a new Cat Flap After connecting to the Cat Flap Computer Application click on the Updates page to see what firmware version is on your Cat Flap the latest firmware version available and to download any updates About On the Abo...

Страница 14: ...e no radio frequency transmitting devices or electronic devices that may be interfering with the operation of the Cat Flap If problem continues reprogram pet see Relearn Pet section If problem continues after reprogramming pet contact Customer Care Centre Cat Flap is not reading key fast enough for pet If you have multiple pets make sure each pet s Re latch Time is set to 1 or 2 seconds see Re lat...

Страница 15: ... Compartment Also make sure battery is fully charged Reset Button If a problem continues or if you still have issues after turning off your Cat Flap you may need to reset your Cat Flap The Reset Button reboots your Cat Flap while keeping your programmed settings The Reset Button is the small pin sized button located on the Control Panel above the USB Port Use a small pin or paper clip to access th...

Страница 16: ...e complies with Industry Canada Rules This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation ACMA This device complies with the applicable EMC requirements specified by the ACMA Australian...

Страница 17: ...to sending the Product Failure to do so may delay in the repair or replacement of the Product If the Product is deemed to be faulty within 30 days from date of original purchase Radio Systems will organise for a replacement to be sent in advance of returning the faulty Product A Post Bag will be included with the replacement Product for the return of the faulty Product The Product must be returned...

Страница 18: ...si qu au jeu et aux défis rendez vous sur notre site www petsafe net PetSafe producten zijn ontworpen om de relatie tussen u en uw huisdier te verbeteren Bezoek onze website op www petsafe net voor meer informatie over onze uitgebreide productreeks die onder meer omheiningssystemen trainingssystemen blafbeheersing kattenluiken gezondheid en welzijn afvalbeheersing en producten voor spel en uitdagi...

Отзывы: