background image

1  Standby

The Standby key switches 
the amplifier between On 
and Standby mode.

2  Source Up & Down

The Source keys scroll 
through the source inputs.

3  Volume Up & Down

The Volume keys adjust 
the volume level of the 
amplifier. When the HT input 
(HT Loop) is selected the 
Volume keys will have no 
effect.

4  Skip Backward

When connected to a 
computer using the USB 
input, the Skip Backward 
key allows you to skip 
backward by one track 
in the music application 
running on the computer. 
The USB input must 
be selected for this to 
function.

5  Play/Pause

When connected to a 
computer using the USB 
input, the Play/Pause 
key allows you to play 
and pause the music 
application running on the 
computer. The USB input 
must be selected for this 
to function.

Operation - Remote Control

6  Skip Forward

When connected to a 
computer using the USB 
input, the Skip Forward key 
allows you to skip forward 
by one track in the music 
application running on the 
computer. The USB input 
must be selected for this to 
function.

7  Stop

When connected to a 
computer using the USB 
input, the Stop key allows 
you to stop the music 
application running on the 
computer. The USB input 
must be selected for this to 
function.

8  Display

The Display key adjusts the 
display options, scrolling 
through FULL, MEDIUM 
and LOW brightness and 
display OFF, although the 
Standby LED will remain on 
at a reduced brightness. If 
the display is set to OFF, the 
display will turn on when the 
source input is changed then 
automatically turn off.

9  Mute

The Mute key causes the 
volume level of the amplifier 
and the preamp outputs to 
be muted. The mute mode 
is indicated by the selected 
input LED flashing gradually. 
Press again, or increase the 
volume, to cancel mute.

10 Direct Source Keys

The Direct Source Keys 
provide direct selection of 
source inputs.

8

Содержание Audiant 80i

Страница 1: ...Owners Manual Audiant 80i Integrated Amplifier...

Страница 2: ...plied with a non rewireable mains plug for the intended country Replacement mains leads can be obtained from your Perreaux dealer Should you need to change the plug please dispose of it carefully A pl...

Страница 3: ...supply only of the type described in the operating instructions and or as marked on the rear of the unit DO NOT defeat the safety earth of the grounding type mains plug severe injury or death may res...

Страница 4: ...t integrated amplifier you will discover many more of the musical secrets we strive to reveal From all of us at Perreaux thank you for choosing the Audiant 80i integrated amplifier INTRODUCTION 3 INST...

Страница 5: ...iod of time its temperature may rise above the designated operating level and the over temperature protection will trip see Protection System section Other Devices Ideally your Audiant 80i integrated...

Страница 6: ...replace this fuse with another of the same type and rating 3 Mains Fuse The mains fuse is user serviceable and should always be replaced with the same type and rating see Technical Specifications pag...

Страница 7: ...peakers 9 HT Loop Input The Home Theatre Loop is used to integrate the Audiant 80i into a home theatre system that has preamp outputs on the surround processor or receiver Please ensure the volume lev...

Страница 8: ...it may be recorded The input should not be changed whilst recording 3 Volume Control The Volume Control increases decreases the level of the sound from the outputs of the amplifier This control affec...

Страница 9: ...a computer using the USB input the Skip Forward key allows you to skip forward by one track in the music application running on the computer The USB input must be selected for this to function 7 Stop...

Страница 10: ...Detection The AC fail detection system monitors the AC voltage on the main power transformer If for any reason the AC mains voltage is lost e g power failure or tripped circuit breaker the speakers ar...

Страница 11: ...uzz or hum Ensure no interconnects are loose or defective Ensure that your tape deck turntable is not too close to the amplifier Unable to make or play tape recordings Check Line Out has been connecte...

Страница 12: ...8 130Wrms into 4 Total Harmonic Distortion THD N Typically 0 002 1kHz 80W into 8 20Hz to 20kHz 0 05 80W into 8 0 05 1W into 8 Frequency Response 0 1dB 20Hz to 20kHz Signal to Noise Ratio A weighted 10...

Страница 13: ...BFS 20Hz to 20kHz 0 004 20dBFS Frequency Response 0 2dB 20Hz to 20kHz Signal to Noise Ratio A weighted 120dB ref 0dBFS Phono Stage Gain 40dB Input Impedance 47k Input Capacitance 100pF Total Harmonic...

Страница 14: ...Dimensions 431mm 17 0 67mm 2 6 309mm 12 2 13...

Страница 15: ...________________________________________________________________________________________________ _____________________________________________________________________________________________________ _...

Страница 16: ...Perreaux Industries Ltd PO Box 305 Mosgiel Dunedin 9053 New Zealand T 64 3 489 2975 F 64 3 489 2976 E nz info perreaux com W www perreaux com...

Отзывы: