Страница 3: ...onnectMe 3 Installation The ConnectMe must be installed by an authorized service technician If ConnectMe is wrong fully installed it can cause damage to the ConnectMe the wheelchair and or other property ...

Страница 4: ...ConnectMe 4 Installation F3 F5 M3 M5 1 Switch the main fuse to OFF position 2 Remove the two knobs holding the top chassis covers ...

Страница 5: ...ConnectMe 5 Installation F3 F5 M3 M5 3 Remove the top cover 4 Pull the rear chassis cover backwars to remove it ...

Страница 6: ...ConnectMe 6 Installation F3 F5 M3 M5 5 Pull the front chassis cover forward to remove it 6 Locate the ICS Master Module in the front of the chassis ...

Страница 7: ...ConnectMe 7 Installation F3 F5 M3 M5 7 Remove the plastic plug covering J6 connector Recycle the plug 8 Locate the J6 serial channel PC and the R net connector 3 on the ICS box ...

Страница 8: ...ConnectMe 8 Installation F3 F5 M3 M5 9 Connect the ConnectMe R net cable to the connector marked with 3 in the illustration 10 Connect the ConnectMe ICS cable to the J6 connector ...

Страница 9: ...llation F3 F5 M3 M5 11 Push the cable box down between the ICS module and the chassis according to the illustration 12 Route the cable backwards on the right side of the chair Push the cable down in the two cable guides ...

Страница 10: ...llation F3 F5 M3 M5 13 Remove the plastic film covering the Dula lock Mount it on the ConnectMe box 14 Remove the plastic film covering the other side of the Dula lock Push the EPDM rubber againts the adhesive to fix it ...

Страница 11: ...ConnectMe 11 Installation F3 F5 M3 M5 15 Remove the plastic film covering the EPDM rubber 16 Clean the area shown in the illustration ...

Страница 12: ...ConnectMe 12 Installation F3 F5 M3 M5 17 Fix ConnectMe on the battery wall according to the illustration 18 Mount rear cover ...

Страница 13: ...ConnectMe 13 Installation F3 F5 M3 M5 19 Mount top cover 20 Mount front cover ...

Страница 14: ...ConnectMe 14 Installation F3 F5 M3 M5 21 Fix the covers with the knobs 22 Turn the main fuse to ON position ...

Страница 15: ...ConnectMe 15 Installation M300 M400 1 Switch off the main fuse It is located below the rear lights on the chassis 2 Remove the two knobs holding the chassis front cover ...

Страница 16: ...lation M300 M400 3 Remove the rear chassis cover by lifting it upwards and backwards On wheelchairs equipped with lights disconnect the rear lights cabling 4 The ICS Master Module is located behind the rear chassis cover ...

Страница 17: ... 17 Installation M300 M400 5 Remove the cover of the ICS Master Module by sliding it off 6 On the cover of the ICS Master Module there is connection overview Plug in the ConnectMe ICS connector in connection J3 ...

Страница 18: ...ConnectMe 18 Installation M300 M400 7 Hold the cable according to the picture and slide the cover of the ICS Master Module back in place 8 Connect the R net cable in the R net bay underneath the fuse ...

Страница 19: ...ConnectMe 19 Installation M300 M400 9 Clean the area under the fuse and mount the Dula lock on it 10 Fix ConnectMe to the main fuse with the cables to the right ...

Страница 20: ...ConnectMe 20 Installation M300 M400 11 Route the cable according to the illustration 12 Route the cable according to the illustration ...

Страница 21: ...ConnectMe 21 Installation M300 M400 13 Route the cable according to the illustration 14 Mount the rear cover ...

Страница 22: ...ConnectMe 22 Installation M300 M400 15 Mount the two knobs holding the top chassis covers 16 Switch the maine fuse to ON position ...

Страница 23: ...wheelchair already in field will require dedicated tools and needs to be done by Permobil authorized service The wheelchair needs to be programmed with the correct firmware and a ConnectMe configuration in order to work properly If ConnectMe emits a steady red light when connected or any other error code there s an error with the installation or product If that s the case please contact customer ...

Страница 24: ...2G or 3G cellular coverage exist at all perform this step at another location with cellular coverage 3 Go blue if a Bluetooth connection is established 4 Remain green or blue without any red colors showing when wheelchair is kept ON If step 1 4 is proceeded successfully ConnectMe device is correctly installed and wheelchair software do not need to be updated If step 2 or 4 fails The software needs...

Страница 25: ...ed 2 Program the ICS with the latest software using WheelchairBuilderX X is 4 or later 3 Program the chassie number of the wheelchair into the ICS using WheelchairBuilderX X is 4 or later 4 Make sure the ICS serial number is programmed 5 Program the URIB with the latest software using the UribUpgradeTool 6 After software update check ConnectMe LED behavior again according to Nominal ConnectMe LED ...

Страница 26: ......

Отзывы: