Honeywell  v12 & v48 Keyswitch wiring & programming                RDC_3142_E_TA 

 

Honeywell  V12 & V48  Alarm Panel 

 

Keyswitch wiring   

 

Keyswitch programming  

NB: V48v4.1+     DO NOT:  Zone double for keyswitch zone 

                         Keyswitch a zone on any expander. 

Background: There are three (3) Outputs available. 

  Outputs are 

‘Open Collector’ @50mA switching negative - for heavier loads a relay must be used.  

  Outputs can be used for e.g. Keyswitch, opening gates or doors etc. 

  Ensure there is a common negative between Permaconn and the device being switched.  

  The outputs can be Opened, Closed or Pulsed remotely using the Permaconn Atlas web portal.  

 

The Pocket Secure App can only ‘Pulse’ the Outputs. A Pulse is approx 1sec. 

 

  These outputs when wired to a Keyswitch zone on the Alarm Panel can arm & disarm up to a  

maximum of thr

ee (3) areas when using ‘Pocket Secure’ app. 

  Each area should be independently controlled using a separate Keyswitch zone. 

  Arm/Disarm reporting 

MUST be Enabled

. Pocket Secure App requires this for its status notifications. 

  Test each Output by placing the +ve leg of a multi meter on the +ve terminal that supplies power to the 

Permaconn, then place the -ve leg of a multi meter on the Output terminal you wish to test. Pulse the 
selected Output the result should go from 0v DC to 12v DC for approx 1sec and back to 0vDC. 

 

E.g. 1:  Keyswitch wiring between Permaconn and Honeywell v12 / 48 Alarm Panel 

single zone Not Using Zone Doubling

Fit EOL resistor in parallel with zone input, then install a wire between the PM45-4G output and the zone input.  
The zone must then be programmed for ‘Momentary Keyswitch’ operation. 
 

Example programming showing v48, Zone 8 as Keyswitch on a PM45v3 4G. 

 

Zone

Com

+

-

Common -ve

Vista

12a
48a

2

k

 

  Each area should be independently controlled using a separate Keyswitch zone. 

 

Any zone can be used as a keyswitch zone.  

 

Sends event (E409 U000 for Disarm) & (R409 U000 for Arm) for keyswitch. 
 

Compatible with ‘Pocket Secure’ remote arming App, available on iTunes, Google Play and the Windows Phone Store. 

 

 

1st Band

1

st

 Digit

2nd Band

2

nd

 Digit

3rd Band
mulitplier

4th Band

Tolerance

   2K

Ω resistor

Red = 2

Black = 0

Red = 10

2

2

0

00

  

= 2K

 