background image

 

Section B: Limited Warranty 

 

B:

 

L

IMITED 

W

ARRANTY

 

Perma Pure LLC 

WARRANTY and DISCLAIMERS 

 

Perma Pure (Seller) warrants that product supplied hereunder shall, at the time of delivery to Buyer, 
conform to the published specifications of Seller and be free from defects in material and 
workmanship under normal use and service. Seller’s sole obligation and liability under this warranty is 
limited to the repair or replacement at its factory, at Seller’s option, of any such product which proves 
defective within one year after the date of original shipment from seller’s factory (or for a normal 
usable lifetime if the product is a disposable or expendable item) and is found to be defective in 
material or workmanship by Seller’s inspection. 

Buyer agrees that (1) any technical advice, information, suggestions, or recommendations given to 
Buyer by Seller or any representative of Seller with respect to the product or the suitability or 
desirability of the product for an particular use or application are based solely on the general 
knowledge of Seller, are intended for information guidance only, and do not constitute any 
representation or warranty by Seller that the product shall in fact be suitable or desirable for any 
particular use or application; (2) Buyer takes sole responsibility for the use and applications to which 
the product is put and Buyer shall conduct all testing and analysis necessary to validate the use and 
application to which Buyer puts the product for which Buyer may recommend the use or application of 
the product by others; and (3)  the characteristics, specifications, and/or properties of the product may 
be affected by the processing, treatment, handling, and/or manufacturing of the product by Buyer or 
others and Seller takes no responsibility for he nature or consequence of such operations or as to the 
suitability of the product for the purposes intended to be used by Buyer or others after being 
subjected to such operations. 

SELLER MAKES NO OTHER WARRANTY, EXPRESS OR IMPLIED, OF THE PRODUCT 
SUPPLIED HEREUNDER, INCLUDING, WITHOUT LIMITATION, IMPLIED WARRANTIES OF 
MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE, AND ALL SUCH 
WARRANTIES ARE HEREBY EXPRESSLY EXCLUDED. SELLER SHALL HAVE NO LIABILITY 
FOR LOSS OF PROFITS, OR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES UNDER 
ANY CIRCUMSTANCES OR LEGAL THEORY, WHETHER BASED ON NEGLIGENCE, BREACH 
OF WARRANTY, STRICT LIABILITY, TORT, CONTRACT, OR OTHERWISE. SELLER SHALL IN 
NO EVENT BE LIABLE IN RESPECT OF THIS ORDER AND OR PRODUCT DELIVERED ON 
ACCOUNT OF THIS ORDER FOR ANY AMOUNT GREATER THAN THAT PAID TO SELLER ON 
ACCOUNT OF THIS ORDER. 

Содержание Baldwin series

Страница 1: ...LC Tel 732 244 0010 1001 New Hampshire Ave Tel 800 337 3762 toll free US Lakewood NJ 08701 Fax 732 244 8140 www permapure com Email info permapure com INSTRUCTION MANUAL HEATED FILTER PROBES GENERAL PURPOSE SERIES Model 34C MONSOL Version 4 05 ...

Страница 2: ...TABLE OF CONTENTS Table of Contents 2 A Specifications 3 B Limited Warranty 4 C Principle of Operation 5 D Maintenance 6 E Troubleshooting 7 F Spare Parts 8 Appendix 9 ...

Страница 3: ...oil Dimensions 14 x 12 x 8 HWD w o Stinger probe Weight 34 lbs Operating Specifications Calibration Gas Requirement 20 psig 6 10 LPM Probe Operating Temperature 375ºF 190ºC Blowback Duration 5 sec standard 30 sec maximum Blowback Valve 24 VDC Blowback Flowrate 14 scfh Instrument Air for Blowback Min 50 psig Max 90 psig Material Specifications Enclosure Material NEMA 4 Steel Probe Stinger 316L SS t...

Страница 4: ...irable for any particular use or application 2 Buyer takes sole responsibility for the use and applications to which the product is put and Buyer shall conduct all testing and analysis necessary to validate the use and application to which Buyer puts the product for which Buyer may recommend the use or application of the product by others and 3 the characteristics specifications and or properties ...

Страница 5: ...a stack or duct with a 1 Schedule 40 male pipe nipple This pipe nipple can be screwed into a standard ASA flange either flat or raised face The probe boot can be heat shrunk to the sample line to eliminate cold spots Blowback The Model 34C comes with a blowback air accumulator tank and 2 way solenoid To operate blowback connect a 50 90 psig instrument airline to the blowback air accumulator tank T...

Страница 6: ...njunction with the Baldwin Series Flow Control Drawer monitoring the sample vacuum will warn the operator when to change the filter element The operator should log the beginning sample vacuum when the system is first started up Keeping a daily log of the sample vacuum will notify the operator what frequency of blowback is required and when increasing frequency of blowback is ineffective in reducin...

Страница 7: ...open for heater resistance the fusible link has blown and the jacket should be replaced Filter plug cannot be removed from filter housing Check O rings for damage High particulate loading Replace O rings Clean the O ring sealing surfaces with a clean towel prior to reassembly Air from blowback tank keeps leaking onto sample when not activated Voltage going to solenoid is 15VAC or less Disassemble ...

Страница 8: ...ment 316L SS 1 25 x 2 975 10 Micron 3PAM 006PK Gasket Graphoil 1 25 10 pack 3PHS 417 Heater Cartridge 350W 3PAM 028PK O Ring Silicone 50 Durometer 10 pack 3PAM 010PK O Ring Viton 50 Durometer 10 pack 3PAM 031PK O Ring Pack Viton C series probes only 5 ea 1 OD 2 OD 2VRS 008 Valve Check Viton O Ring 2VS2 015 Valve Solenoid 2 Way 24VDC 316SS ...

Страница 9: ...9 APPENDIX ...