background image

INSTALLATION AND OPERATION INSTRUCTIONS

18” SHALLOW-DEPTH SERIES

IMPORTANT INFORMATION

To  register  your  product,  visit  our  web  site  at  

(www.perlick.com).  Click  on  “Commercial”,  then 

“Service”. You will see the link to “Warranty Registration 

Form”. You must complete and submit this form or the 

installation date will revert back to the ship Date.
This manual has been prepared to assist you in the 

installation of your Cabinet and to acquaint you with 

its operation and maintenance.
We  dedicate  considerable  time  to  ensure  that  our 

products  provide  the  highest  level  of  customer  

satisfaction.  If  service  is  required,  your  dealer  can 

provide you with a list of qualified service agents. For 

your  own  protection,  never  return  merchandise  for 

credit without our approval.
We  thank  you  for  selecting  a  Perlick  product  and 

assure  you  of  our  continuing  interest  in  your 

satisfaction.

8300 West Good Hope Road   •   Milwaukee, WI  53223   •   Phone  414.353.7060   •   Fax  414.353.7069

Toll Free  800.558.5592   •   E-Mail  [email protected]   •   www.perlick.com

C

US

Table of Contents

Introduction ................................................................ 1

Preparing the cabinet for use

General Precautions .................................................. 2

Installation Notes ....................................................... 2

Dimensions Diagram ................................................. 3

Preparing the Space .................................................. 4

Preparing Electrical Connections .............................. 4

Unpacking/Moving the Unit........................................ 5

Anti-tip Bracket Information ....................................... 5

Installation

Installation Instructions .............................................. 6

Shelving ..................................................................... 8

Door Panel Options ................................................... 8

Door Lock Installation ................................................ 9

Operation ................................................................. 10

Maintenance ............................................................ 11

Troubleshooting ....................................................... 12

PERLICK COMMERCIAL WARRANTY: 

This 

Commercial Refrigerator comes with a five-year 

compressor warranty and a one-year parts and labor 

warranty (with the option to purchase a second year).

WARNING: When lifting, the full weight of the 

cabinet must be supported. Lift from the cabinet 

base and not from the top. Improper lifting can 

result in severe damage to the cabinet.

 

Form No. Z2325

MODEL:

  HD24 SERIES

Содержание HD24 SERIES

Страница 1: ... and assure you of our continuing interest in your satisfaction 8300 West Good Hope Road Milwaukee WI 53223 Phone 414 353 7060 Fax 414 353 7069 Toll Free 800 558 5592 E Mail perlick perlick com www perlick com C US Table of Contents Introduction 1 Preparing the cabinet for use General Precautions 2 Installation Notes 2 Dimensions Diagram 3 Preparing the Space 4 Preparing Electrical Connections 4 U...

Страница 2: ...e to clean the condenser every three months can cause the unit to malfunction This could void the warranty 3 Never install the unit behind closed doors ie closets small pantries etc Be sure front louvered toe plate is free of obstruction Obstructing free air flow can cause unit to malfunction and may void the warranty 4 Use only Perlick replacement parts Use of non Perlick parts can damage the uni...

Страница 3: ...k is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice 3 Form No Z2325 18 SHALLOW DEPTH SERIES Operation Installation Manual Figure 1 Dimensions ...

Страница 4: ...floor PREPARING ELECTRICAL CONNECTIONS A 115 volt 60Hz 15 amp circuit breaker and electrical supply are required A separate circuit is recommended Follow the National Electrical Code along with local codes and ordinances when installing the receptacle All Perlick units come equipped with a NEMA 5 15P 90 plug with a 5 cord minimum extending beyond the rear of the unit The electrical outlet must be ...

Страница 5: ... brackets Refer to Figure 3 for mounting bracket locations IMPORTANT If installing on a concrete floor concrete fastners are required and are not included in the Anti Tip Kit UNPACKING AND MOVING THE UNIT CAUTION Do not cut cardboard sleeve covering the unit Cutting may result in damage to the exterior of the unit 1 Uncrate the unit on a flat level surface Remove the cardboard sleeve by removing t...

Страница 6: ...Figure 3 and perform the following A Measure from the floor to the bottom of the front edge of the countertop B Measure the rear of unit cabinet from floor to top of cabinet at back corners C Adjust rear legs so B measurement equals A measurement Using an adjustable wrench or pliers turn legs counterclockwise to raise the unit or clockwise to lower the unit IMPORTANT Leveling legs should not exten...

Страница 7: ... is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice 7 Form No Z2325 18 SHALLOW DEPTH SERIES Operation Installation Manual Figure 4 Wall Bracket ...

Страница 8: ...he bracket pull the front end up and out then forward to remove Figure 5 3 Place bracket at the desired position Push the rear hook into the rear key slot Set front of bracket on the wall hook 4 Repeat for other bracket s 5 Push extenders completely into the unit Align the shelf grooves with the extenders and slide completely into the unit DOOR PANEL OPTIONS Perlick units offer a variety of door p...

Страница 9: ...Lock Washer Screw Lock Bracket 1 Attach bracket to wood overlay 2 Insert lock body 3 Add and tighten nut 4 Add lock strike 5 Add lock washer and screw 6 Use key to turn the lock and verify that the lock and unlock positions of the strike are correct unlock should be up lock should be horizontal 7 Adjust lock if necessary 8 Attached overlay with lock assembly to the door assembly 9 Attach lock brac...

Страница 10: ...g a solid door If manual switch is left on for an extended period of time it may increase the cabinet temperature especially at the top and cause the refrigeration system to run longer Loading Product IMPORTANT When loading items into unit do not block interal louvers and fan guard openings or performance will be decreased Temperature Control The controller is located at the top rear panel of the ...

Страница 11: ...alled Door gasket and sealing Amount of time internal light is illuminated Installation in direct sunlight or near a heat source MAINTENANCE WARNING Shut off the electricity to the unit before cleaning the condenser and other routine maintenance Cleaning To clean stainless steel exterior or interior surfaces use a soft non abrasive stainless steel cleaner to wipe down the surfaces Glass doors can ...

Страница 12: ...t isn t running Is there electrical power to the unit Is the building circuit breaker fuse on Is the control set properly In the condenser area clean The refrigerated compartment is warmer than usual Is the control set properly Is the light staying on Is the condenser area clean and free of obstruction Has the door been open for a long time or more frequent door openings occurred Are the internal ...

Страница 13: ... for planning installation or product information Write Perlick Corporation Customer Service Department 8300 W Good Hope Rd Milwaukee WI 53223 E mail us at warrantyserv perlick com To obtain product service replacement parts or accessories Use only genuine Perlick replace parts and accessories Genuine Perlick parts and accessories are designed to work correctly with Perlick products and offer supe...

Страница 14: ...Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice 14 Form No Z2325 NOTES ...

Страница 15: ...Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice 15 Form No Z2325 NOTES ...

Страница 16: ...8300 West Good Hope Road Milwaukee WI 53223 Phone 414 353 7060 Fax 414 353 7069 Toll Free 800 558 5592 E Mail perlick perlick com www perlick com Form No Z2325 Perlick Generations of Excellence ...

Отзывы: