6.4 Condenser Coil Cleaning
•
Perlick’s warranty does not cover cleaning of
the condenser coil.
•
The condenser coil should be free obstruction,
dust and debris. The condenser coil should be
cleaned every 6 months or more or less often
dependent upon the environment.
To clean the condenser:
1. Open the door and remove the grill by pulling
away from the cabinet (grill is held on by four
(4) latch and mate connectors).
See Figure
6-7.1.
2. Once the grill is removed, using a soft brush
and vacuum, remove any dust or debris, being
careful to avoid damaging (bending) the fins on
the condenser coil.
See Figure 6-7.2.
3. Once cleaned, reinstall the grill.