background image

Column Refrigeration Service Manual   

Return to 

Table of Contents

 

44

STEP 1 - Door Gaskets

 

   

Check door gaskets for rips, cracks, or other 

damage.

The door gasket should be pushed in firmly and lay 

flat.

Ensure gasket forms a complete seal around the 

door.

6.0

 

 Refrigeration System Repair  

6.1 

Air Infiltration   

Air infiltration can occur in several locations.

NOTE: Unit may manifest longer than normal 

run times caused by the additional loads that air 

infiltration presents.
Signs of air infiltration include:

• 

Presence of water, moisture or ice

• 

Condensation on glass or metal surfaces

STEP 2 - Sealing Compound

 

   

Sealing compound is used to seal wiring and line 

set pass-through between the condenser and the 

evaporator compartments. 

See Figure 6-1.1 and 

6-1.2.
Additionally, sealing compound is used to seal door 

switch wiring pass-through holes at top of cabinet. 

See Figure 6-1.3 and 6-1.4.

 

Check for voids and ensure sealing compound 

completely fills space (both on interior and exterior 

openings (if both tubes and wires pass-through and 

opening, ensure sealing compound is used between 

the items).

Figure 6-1.1. Sealing Compound (Inside)

Figure 6-1.2. Sealing Compound (Outside)

Figure 6-1.3. Sealing Compound - Door Switch (Inside)

Figure 6-1.4. Sealing Compound - Door Switch (Outside)

Содержание CC24D Series

Страница 1: ...ation Residential and Commercial Product Series Covered in this Manual Commercial CC24D CC24W Residential CR24D CR24F CR24R CR24W CR30R Scan here to download a PDF copy of this manual Form No Z2551 Rev C 05 03 2019 CC24W CR24F CR24R ...

Страница 2: ... 3 3 Doors Drawers Shelving 19 4 0 ELECTRICAL COMPONENTS AND SPECIFICATIONS 20 4 1 Compressor 20 4 1 1 MODEL VEMX5C 20 4 1 2 MODEL VEMZ9C 20 4 2 Inverter 20 4 2 1 Drop In 20 4 2 2 MODEL Frequency Drive 20 4 3 Condenser Fan Motor 20 4 4 Evaporator Fan Motor 20 4 5 Hot Gas Defrost Solenoid Valve 21 4 6 Control 21 4 7 Damper 21 4 8 User Interface 21 5 0 COMPONENT OPERATION 22 5 1 Modes Of Operation 2...

Страница 3: ... Freezer Temperature 37 5 6 3 Column Theater Lighting 38 5 6 4 Changing From Fahrenheit To Celsius Scale 38 5 6 5 Sabbath Mode 38 5 6 6 Quick Cool Shopping Mode 38 5 6 7 Showroom Mode 39 5 7 Wine Reserve Control Operation 40 5 7 1 Using The Wine Column Control 40 5 7 2 Selecting A Temperature Zone 40 5 7 3 Storing White Wine 41 5 7 4 Storing Red Wine 41 5 7 5 Cellaring Wine 42 5 7 6 Column Theater...

Страница 4: ...tions 72 7 4 2 Troubleshooting 73 7 5 Door Switch 73 7 5 1 Troubleshooting 73 8 0 DOORS DRAWERS SHELVING AND MISC 74 8 1 Overlay Panel Installation And Adjustments 74 8 2 Top Of Door Illustration 75 8 3 Door Trim Installation 76 8 4 Grill Installation 77 8 5 Toe Kick Clearance 78 8 6 Installing Filters 79 8 6 1 Carbon Air Filters 79 8 6 2 Ethylene Filters 79 8 7 Activation De activation Of Hinges ...

Страница 5: ...109 8 19 2 Anti Tip Installation For Freestanding Installation 110 8 20 Marriage Kit Installation 111 8 21 Butter Bin 115 8 22 Trim Kits 116 9 0 REPLACEMENT PARTS 117 9 1 CR24R CR24D CR24W CC24D CC24W And CR30R Refrigeration Module 117 9 2 CR24F Refrigeration Module 118 9 3 CR24F Drawers 119 9 4 CR24R Shelving 120 9 5 CR30R Shelving 121 9 6 CR24R CR24F And CR30R Door 122 9 7 CR24R And CR30R Drawer...

Страница 6: ...Switch Inside 44 Figure 6 1 4 Sealing Compound Door Switch Outside 44 Figure 6 2 1 Refrigerator Gasket 45 Figure 6 2 2 Lift Bolts 45 Figure 6 3 Evaporator Condensate Drain 45 Figure 6 4 1 Grill Toe Kick Inlet and Outlet 46 Figure 6 4 2 Evaporator Intake Openings 46 Figure 6 5 1 Evaporator Air Outlet Louvers 47 Figure 6 5 2 Evaporator Air Damper Outlet Openings 47 Figure 6 6 Condenser Airflow Divid...

Страница 7: ...le LED Descriptions 64 Figure 7 2 1 Remove Wine Shelving 66 Figure 7 2 2 Pry Light Covering 67 Figure 7 2 3 Pry Light Housing Board 67 Figure 7 2 4 Disconnect Board From Harness 68 Figure 7 2 5 Remove Wine Shelving 68 Figure 7 2 6 Remove Carbon Filter 69 Figure 7 2 7 Remove Wire Harness Cover 69 Figure 7 2 8 Remove Controller Cover 70 Figure 7 2 9 Disconnect Light Harness 70 Figure 7 3 1 Evaporato...

Страница 8: ... Wine Shelves 103 Figure 8 18 Freezer Shelving 104 Figure 8 19 Refrigerator Shelving 105 Figure 8 20 1 8 20 2 Dual Zone Compartment Divider 106 Figure 8 21 Leveling Alignment 107 Figure 8 22 1 Anti tip Installation Integrated 109 Figure 8 22 2 Anti tip Installation Freestanding 110 Figure 8 23 1 8 23 4 Marriage Kit Install 111 Figure 8 24 1 Butter Bin 115 Figure 8 25 Trim Kit 116 Figure 9 1 CR24R ...

Страница 9: ... 20 Table 4 5 Hot Gas Defrost Solenoid Valve Specs 21 Table 4 6 Control Specs 21 Table 4 7 Damper Specs 21 Table 5 1 1 Modes of Operation CR24R and CR30R 22 Table 5 1 2 Modes of Operation CR24F 23 Table 5 1 3 Modes of Operation CR24W CC24W 24 Table 5 1 4 Modes of Operation CR24D CC24D 25 Table 5 2 Electrical Specifications 26 Table 5 3 Control Alarms 31 Table 5 4 Low High Temperature Alarm Offsets...

Страница 10: ...or require additional assistance contact Perlick Customer Service during regular hours of operation 1 2 Model Families This manual contains specific instructions for servicing the Perlick Residential and Front Venting Commercial Series refrigeration products which include the following families RESIDENTIAL COMMERCIAL CR24D CC24D CR24F CC24W CR24R CR24W CR30R 1 3 I D Label The model and serial numb...

Страница 11: ...system leaks if system is in a vacuum All self contained models covered in this service manual are manufactured using refrigerant HC 600a Isobutane 2 2 Servicing with R 600a R600a is a hydrocarbon This refrigerant is flammable and is only allowed for use in appliances which fulfill the requirements of UL 60335 2 24 To cover potential risk originated from the use of flammable refrigerants Consequen...

Страница 12: ...ct Safety Labels Figure 2 1 6 Warning Transporting Hazard Label Figure 2 1 7 Uncrating Label Figure 2 1 1 Danger Fire Explosion Risk Label Figure 2 1 2 Danger Fire Explosion Risk Servicing Label Figure 2 1 3 Warning Handling Label Figure 2 1 4 Warning Tip Over Hazard Label Figure 2 1 5 Disposal Label ...

Страница 13: ...tinuity of wires Power Requirements not within specification Verify that power at receptacle is the same as nameplate rating Cord and Plug Loose Connection Check for continuity of wires Defective Replace Unit in Showroom Mode Disable showroom mode See User Interface Section Internal Wiring Loose Connection Check for continuity or voltage at control board or check for heartbeat on control board See...

Страница 14: ...nal Damage Verify Amperage Refrigerant Leak See Section 6 11 Refrigerant Circuit Restriction Replace Refrigeration Module Hot Gas Bypass Valve Internal Leak Check Valve Damper Obstructed Remove Obstruction Power Determine if damper is getting power Defective Replace Thermistors Loose Connection Verify Continuity Defective Verify Component Specifications Temp Humidity Sensor Defective Verify Compon...

Страница 15: ...is installed properly Reed Switch Wire Hole Ensure reed switch wire hole is sealed with permagum Thermistors Loose Connection Verify Continuity Defective Verify Component Specifications Temp Humidity Sensor Defective Verify Component Specifications Loose Connection Verify Continuity Evaporator Dirty Clean Defective Verify Component Specifications Evaporator Fan Motor s Fan Blades Binding Remove Ob...

Страница 16: ...emove Obstruction Power Determine if damper is getting power Defective Replace Obstructed Airflow Check airflow inlet and outlet for obstructions Remove Obstruction PROBLEM CAUSE SOLUTION Noisy Operation Airflow Noise Condenser Fan Motors Airflow noise from the condenser fans is normal Evaporator Fan Motors Airflow noise from the evaporator fans is normal Clicking Crackling During Defrost Solenoid...

Страница 17: ...calling for cooling Evaporator Fans not Running Ensure unit is not in Showroom Mode Take unit out of Showroom mode Control board Evap Fan LED illuminated Green LED LED7 should illuminate when call for Evap Fans Check power at control board Connector P12 Red to Black 12VDC Check power at fan terminal block 12VDC at block Condenser Fans not Running Ensure unit is not in Showroom Mode Take unit out o...

Страница 18: ...justed to Blue Adjust Intensity to Blue Reed switch is closed Check continuity of reed switch magnet on door Control Board Blue LED Illuminated Green LED LED5 should illuminate when call for blue lights Check power at control board Connector P13 Blue to Black 12VDC Loose Connection Check connections Hot Gas Valve Solenoid Freezer Only Is unit in Defrost Mode Operates only when in defrost mode Cont...

Страница 19: ... environmental conditions Refer to Refrigeration System Repairs Ambient Temperatures Frequent Door Openings Refer to Door Drawers and Shelving Key Won t Come Out Of Lock Key not in proper position Rotate key to the proper position and remove Excessive wear Replace Worn Parts Wrong Orientation Verify orientation Push To Open Drawers Drawers won t open Verify push to open mechanisms work properly Dr...

Страница 20: ...riable Capacity Speed Hermetic Reciprocating Compressor Nominal Voltage Frequency Phase 230V 53 150Hz 3 Ph Refrigerant R 600a Refrigerant Grade Isobutane Commercial Designation 1 5 HP Starting Device Type Inverter Start Winding Resistance 16 07 77 F 8 Run Winding Resistance 16 07 77 F 8 Locked Rotor Amperage 2 10 A Full Load Amperage 2 10 A 4 2 1 Drop In Model EM Used with VEMX5C Compressor Input ...

Страница 21: ...Damper 4 8 User Interface Custom Design Connect only to Perlick Column Control Board Table 4 5 Hot Gas Defrost Solenoid Valve Specs Table 4 6 Control Specs Table 4 7 Damper Specs Coil Rating 12VDC 15W 1 08A 11 1 ohms Specifications Input 120V AC 3 3A max Output Various Specifications 12VDC 0 5W 1850 Step Stepper Motor ...

Страница 22: ... minute delay Compressor Delayed 3 Minutes On Off Off Off Off Condenser Fan Delayed 3 Minutes On Off Off Off Off Evaporator Fan Delayed 3 Minutes On Activated if humidity required Off On Off Tip Out Produce Bin Damper Opening Open until satisfied by temperature Open if humidity required Closed Closed Closed Meat Fish Drawer Damper Opening Open until satisfied by temperature Closed Closed Closed Cl...

Страница 23: ... off mode Model CR24F Component Initial Power Up Cooling Mode 1 Off Mode Defrost Mode 2 Showroom Mode Control Board HeartBeat Flashing Flashing Flashing Flashing Flashing Lights Activated with Door Openings Activated with Door Openings Activated with Door Openings Activated with Door Openings Activated with Door Openings Door Alarm Activated with Door Opening 3 minute delay Activated with Door Ope...

Страница 24: ...ith Door Opening 3 minute delay Activated with Door Opening 3 minute delay Compressor Delayed 3 Minutes On Off Off Off Off Condenser Fan Delayed 3 Minutes On Off Off Off Off Evaporator Fan Delayed 3 Minutes On Activated if humidity required Off On On Off 1 To avoid short cycling of the compressor there is a programmed 3 minute delay 2 Upon the evaporator probe sensing 32 F during the off cycle a c...

Страница 25: ...Delayed 3 Minutes On Activated if humidity required Off On On Off Upper Zone Damper Opening Open until satisfied by temperature Open if humidity required Closed Open Closed Open Closed Lower Zone Damper Opening Open until satisfied by temperature Open if humidity required Closed Open Closed Open Closed 1 To avoid short cycling of the compressor there is a programmed 3 minute delay 2 Upon the evapo...

Страница 26: ... 2 60 1 CORD CONNECTED NEMA 5 15P CR24D AC 115 3 2 60 1 CORD CONNECTED NEMA 5 15P CR24F AC 115 3 3 60 1 CORD CONNECTED NEMA 5 15P CR24R And CR30R AC 115 3 2 60 1 CORD CONNECTED NEMA 5 15P CR24W AC 115 3 2 60 1 CORD CONNECTED NEMA 5 15P Table 5 2 Electrical Specifications Column Refrigeration Service Manual Return to Table of Contents 26 5 2 Electrical Specifications ...

Страница 27: ...Column Refrigeration Service Manual Return to Table of Contents 27 5 3 Wiring Diagrams Figure 5 1 1 Refrigerator Column Wiring Diagram ...

Страница 28: ...Column Refrigeration Service Manual Return to Table of Contents 28 5 3 Wiring Diagrams Figure 5 1 2 Wine Column Single Zone Wiring Diagram ...

Страница 29: ...Column Refrigeration Service Manual Return to Table of Contents 29 5 3 Wiring Diagrams Figure 5 1 3 Wine Column Dual Zone Wiring Diagram ...

Страница 30: ...Column Refrigeration Service Manual Return to Table of Contents 30 5 3 Wiring Diagrams Figure 5 1 4 Freezer Column Wiring Diagram ...

Страница 31: ...Humidity Sensor L1 L2 L3 L4 L5 L6 Low Temperature Alarm Sensed temperature is below X degrees F below setpoint for over 30 minutes H1 H2 H3 H4 H5 H6 High Temperature Alarm Sensed temperature is above X degrees F above setpoint for over 30 minutes r5 r6 Open Disconnected Humidity Sensor d1 door open alarm Low High Temperature Alarm Offsets Alarm Freezer Refrigerator Wine Single Zone Wine Dual Zone ...

Страница 32: ...ce activated the temperature zone selection 2 temperature adjustment 7 temperature readout 8 and settings 15 menu icons will illuminate 5 5 2 Selecting a Temperature Zone Perlick s touch screen controller is preset with recommended temperature settings for various goods Within these presets you have the ability to adjust the temperature in 1 increments as you desire Press the temperature zone sele...

Страница 33: ...ate the new setting 5 5 4 Top Drawer Compartment The deli compartment top drawer of the refrigerator features a two tier design for storing and displaying charcuterie items such as artisan meats and cheeses When this zone is chosen the charcuterie cheese temperature setting 3 temperature adjustment 7 and the temperature readout 8 will illuminate Compartment Sp Factory Setting Temperature Range Del...

Страница 34: ...ng 6 temperature adjustment 7 and temperature readout 8 will illuminate In addition to temperature related icons the humidity control adjustment 10 icon will also illuminate Compartment Sp Factory Setting Temperature Range Tip out Produce Bin 35 F 32 F 37 F As with the other compartments you have the ability to raise or lower the temperature in 1 F increments To adjust the temperature up or down p...

Страница 35: ...s off Sabbath mode 5 5 8 Changing From Fahrenheit To Celsius Scale The controller is factory set to Fahrenheit scale but can easily be changed to read Celsius in the settings menu Press the settings menu 15 icon on the far right This will illuminate a cluster of four icons as shown to the left To activate Sabbath mode press the Sabbath mode icon Please note that when in Sabbath mode the Sabbath mo...

Страница 36: ... right This will illuminate a cluster of four icons as shown to the left A 5 key combination including the Fahrenheit readout 11 icon Celsius readout 12 icon and settings menu 15 icon will activate Showroom mode F C F C Settings Upon activating showroom mode the temperature readout 7 with show Sh each time the door is opened until showroom mode is turned off To exit showroom mode enter the 5 key c...

Страница 37: ...ick column freezers model CR24F Compartment Sp Factory Setting Temperature Range All N A 0 F 10 F 10 F 5 6 1 Using the Freezer Column Control Upon door opening the Wake button 1 outline will illuminate Once activated temperature adjustment 2 temperature readout 3 and settings 9 menu icons will illuminate The freezer will come set from the factory to 0 F To adjust the temperature adjustment 2 arrow...

Страница 38: ...be illuminated to signify the scale 5 6 5 Sabbath Mode All Perlick column refrigeration models have Sabbath mode capabilities This allows the user to interact with the unit without changing the amount of energy it is using In this mode the interior lighting is turned off until user turns off Sabbath mode Press the settings menu 9 icon on the far right This will illuminate a cluster of four icons a...

Страница 39: ...ttings menu 9 icon on the far right This will illuminate a cluster of four icons as shown to the left A 5 key combination including the Fahrenheit readout 5 icon Celsius readout 6 icon and settings menu 9 icon will activate Showroom mode F C F C Settings Upon activating showroom mode the temperature readout 7 with show Sh each time the door is opened until showroom mode is turned off To exit showr...

Страница 40: ...line will illuminate Once activated the temperature zone selection 2 temperature adjustment 7 temperature readout 8 and settings 15 menu icons will illuminate 5 7 2 Selecting A Temperature Zone Perlick s touch screen controller is preset with recommended temperature settings for white wine red wine and cellaring Within the presets you have the ability to adjust the temperature in 1 increments as y...

Страница 41: ...e readout 7 Double beep indicates that minimum or maximum temperature has been reached Temperature will flash twice to indicate new setting 5 7 4 Storing Red Wine Perlick wine columns are preset with expert recommended temperature settings for red wine To set a zone in dual zone models to this preset touch the temperature zone selection icon 2 to illuminate the zone you d like to set to red wine t...

Страница 42: ...g for clear viewing and display of wine bottles Door open white LED lighting runs vertically down the walls and horizontally across the ceiling of each compartment Door closed display lighting can be changed from white to blue blue will only illuminate the side walls Wine models are factory set to white lighting To adjust the brightness of the lighting when the door is opened press the up and down...

Страница 43: ...uickly bring them to the preferred temperature Press the settings menu 15 icon on the far right This will illuminate a cluster of four icons as shown to the left To activate Quick Cool shopping mode press the Quick Cool 14 icon This will activate the mode and the Quick Cool 14 will remain illuminated until the set point is achieved Press the settings menu 15 icon on the far right This will illumin...

Страница 44: ...r ice Condensation on glass or metal surfaces STEP 2 Sealing Compound Sealing compound is used to seal wiring and line set pass through between the condenser and the evaporator compartments See Figure 6 1 1 and 6 1 2 Additionally sealing compound is used to seal door switch wiring pass through holes at top of cabinet See Figure 6 1 3 and 6 1 4 Check for voids and ensure sealing compound completely...

Страница 45: ... See Figure 6 2 2 Check for condensation or cold air around the top perimeter of the refrigeration module or using a bright light shine the light at the gasket and look for light on the other side of the gasket If any condensation cold air or light can be detected around the gasket remove the refrigeration module and inspect the gasket and replace See section Replace Refrigeration Module for detai...

Страница 46: ...at exceed those listed below condensation may start to form on the front face of the cabinet Condensation will subside as conditions return to levels below those shown in the table 6 3 Air Flow Obstructions The unit must have free air flow to the front grill and to the evaporator intake and discharge openings to operate properly Restricted air flow results in high head pressures and reduction in e...

Страница 47: ...oor This divider prevents direct circulation of machine compartment air If missing unit will run extremely inefficiently and extreme high discharge pressures and temperature which could lead to compressor damage See Figure 6 6 Figure 6 6 Condenser Airflow Divider Figure 6 5 1 Evaporator Air Outlet Louvers Figure 6 5 2 Evaporator Air Damper Outlet Openings ...

Страница 48: ...less often dependent upon the environment To clean the condenser 1 Open the door and remove the grill by pulling away from the cabinet grill is held on by four 4 latch and mate connectors See Figure 6 7 1 2 Once the grill is removed using a soft brush and vacuum remove any dust or debris being careful to avoid damaging bending the fins on the condenser coil See Figure 6 7 2 3 Once cleaned reinstal...

Страница 49: ... shelves see Section 8 16 1 and then remove the false inner liner bottom panel See Figure 6 9 1 and 6 9 2 Refrigerator Remove the tip out bin see Section 8 13 and then remove the false inner liner bottom panel See Figure 6 10 2 Using a fan or heat gun direct warm air over the coil to melt the ice See Figure 6 11 NEVER USE TOOLS OR SHARP OBJECTS TO CHIP OR REMOVE ICE FROM THE EVAPORATOR OR TUBES 3 ...

Страница 50: ...he cabinet STEP 2 Remove front lift bracket by removing 3 10 sheet metal screws STEP 3 Disconnect the refrigeration module wiring by removing the bottom panel in the cabinet Shelves or drawers will need to be removed to access the bottom of the cabinet Figure 6 12 1 Remove Grill Figure 6 12 2 Remove Lift Bracket Figure 6 12 3 Disconnect Refrigeration Wiring ...

Страница 51: ...EP 5 Once module is lowered and all wires disconnected slide module out by pulling on the vase panel of the module Protect the floor in front of the unit to prevent scratches to the floor STEP 6 Disconnect the power cord from the rear of the unit after the refrigeration module is removed Figure 6 12 4 Lower Refrigeration Module Figure 6 12 5 Slide Refrigeration Module Out Figure 6 12 6 Disconnect ...

Страница 52: ...nch STEP 10 Reconnect all wiring from the refrigeration module and cabinet The wires from the cabinet and module are color coded to match one another Before proceeding to Step 11 make sure unit is functioning as intended If not ensure all wires are tightly secured STEP 11 Install the cabinet bottom panel and any drawers or shelves removed in Step 3 STEP 12 Reinstall the front lift bracket to the m...

Страница 53: ...odule gasket if worn or damaged See Figure 6 13 6 8 Replace Evaporator Fan Motor Following the instructions for replacing the refrigeration module remove the module from the cabinet Using a phillips screwdriver remove the fasteners holding the evaporator fan motor to the fan housing Using small flat blade screwdriver disconnect fan leads from terminal block Install new fan in reverse manor Re inst...

Страница 54: ...s and washers from the tabs that secure the compressor to the base STEP 3 Carefully lift the compressor up so the rubber feet clear the tabs and rotate the compressor slightly to access the inverter mounting screw 6 9 Replace Inverter Disconnect power to the unit before working on product to avoid electrocution hazard Figure 6 15 1 Remove Cotter Pins Figure 6 15 2 Lift And Rotate Compressor WARNIN...

Страница 55: ...TEP 4 Remove the inverter mounting screw and disconnect the inverter electrical connections STEP 5 Lift the inverter and pull away from compressor Before proceeding ensure power has been disconnected Figure 6 15 3 Inverter Mounting Screw Electrical Connections WARNING Figure 6 15 4 Lift Inverter ...

Страница 56: ...ter cont STEP 6 Remove the three pin connector and ground connector from the compressor using a small flat head screwdriver STEP 7 Install the new inverter and remount the compressor Figure 6 15 5 Remove 3 Pin And Ground Connectors Figure 6 15 6 Install Inverter And Remount Compressor ...

Страница 57: ... wire harness 1015081 connect to black and red connector coming off inverter STEP 9 Feed other end of harness 1015081 through tube wire access hole Single red lead is no longer required remove or wire tie so it is out of the way Figure 6 15 7 Connect Inverter Wires Figure 6 15 8 Feed Harness End Through Access Hole ...

Страница 58: ...ly sealed to prevent air leaks STEP 11 Install refrigeration module following instruction 6 6 STEP 12 New harness 1015081 gets connected to spare black wire lead set from cabinet Note Inverter signal leads are connected to control board connection P4 for the frequency converter Figure 6 15 9 Seal Access Hole Figure 6 15 10 Connect New Harness ...

Страница 59: ... Pull out on the cover to remove the damper assembly Unplug the damper from the wire harness Replace the damper assembly Plug in damper install damper assembly into opening and fasten Reinstalled drawers or shelves Figure 6 16 1 Refrigerator and Dual Zone Wine Lower Damper Figure 6 16 2 Dual Zone Wine Upper Damper Figure 6 16 3 Dual Zone Wine Upper Damper Cover and Insulation Pad Suppressed Figure...

Страница 60: ...O NEARBY IGNITION SOURCES Isobutane R 600a is a low pressure refrigerant 30 PSIG 70 F If checking for a leak the system should be at a minimum temperature of 70 F Use an isobutane R 600a compatible electronic leak detector check all joints tubing and coils for leaks If a leak is detected replace the refrigeration module see Section 6 6 WARNING DANGER ...

Страница 61: ...Column Refrigeration Service Manual Return to Table of Contents 61 6 12 Refrigeration System Diagram Medium Temperature Figure 6 17 1 Refrigeration System Diagram Medium Temperature ...

Страница 62: ...Column Refrigeration Service Manual Return to Table of Contents 62 6 13 Refrigeration System Diagram Freezer Figure 6 17 2 Refrigeration System Diagram Freezer ...

Страница 63: ...ntrol board Remove the P1 plug and mea sure the resistance across F1 It should be 0 ohm Replace the control if P1 is open Table 7 2 LED Troubleshooting Column Refrigeration Service Manual Return to Table of Contents 63 7 0 Component Operation 7 1 Control The column products come with a custom designed control located in on the interior ceiling of the product 7 1 1 Diagnostics See Figure 7 1 for th...

Страница 64: ...Column Refrigeration Service Manual Return to Table of Contents 64 7 1 3 Visible LED Descriptions Figure 7 1 Visible LED Descriptions ...

Страница 65: ...ational check electrical connections from the control board to the user interface Use Control Replacing see section 7 1 4 instructions to access the control board and user interface connections For a refrigerator there is a third connection located at the rear of the user interface housing to access remove the deli bin glass lid by removing the two pivot fasteners one on each end of the lid then p...

Страница 66: ...Column Refrigeration Service Manual Return to Table of Contents 66 7 3 Lighting Replacement 7 3 1 Replace Wine Lighting STEP 1 Remove all shelving Figures 7 2 1 Remove Wine Shelving ...

Страница 67: ...out at the top of each opening lower covers have cut out at the bottom of each opening STEP 3 Light boards are adhesive backed so using a flat blade screwdriver start at one end of board and pry the board of the light housing Gradually work your way from one end to the other to remove completely Be careful while removing cover do not scratch liners CAUTION Figure 7 2 2 Pry Light Covering Figures 7...

Страница 68: ...lace Wine Lighting cont STEP 4 Disconnect board from harness using harness connector to remove Do not pull on wires and cause damage STEP 5 Replace led board with new and continue to replace all four 4 Figure 7 2 4 Disconnect Board From Harness Figure 7 2 5 Remove Wine Shelving ...

Страница 69: ...9 7 3 1 Replace Wine Lighting cont STEP 6 Remove carbon filter from housing at top of cabinet STEP 7 Remove wire harness cover by removing screws that hold it in place Top rear left of cabinet Figures 7 2 6 Remove Carbon Filter Figures 7 2 7 Remove Wire Harness Cover ...

Страница 70: ... main control board and follow wires from sister board to main control board and disconnect and plug light harness directly into main control board Sister board is no longer requirement with new led boards 7 3 2 Replace Freezer and Refrigerator Lighting The freezer and refrigerator lighting can be replaced similarly to the wine instructions however there is no sister board for these two models Add...

Страница 71: ...X degrees F below setpoint for over 30 minutes H1 H2 H3 H4 H5 H6 High Temperature Alarm Sensed temperature is above X degrees F above setpoint for over 30 minutes r5 r6 Open Disconnected Humidity Sensor d1 door open alarm Troubleshooting To troubleshoot check all connections and using a multimeter check resistance values Temperature C Temperature F Resistance OHMS Temperature C Temperature F Resis...

Страница 72: ...rtment and Single Zone Wine Temperature Humidity Sensor Figure 7 3 5 Refrigerator Deli Bin Temperature Probe Figure 7 3 2 Dual Zone Wine Lower Compartment Temperature Humidity Sensor Figure 7 3 4 Freezer and Refrigerator Main Compartment Temperature Probe Figure 7 3 6 Refrigerator Meat Fish Bin Temperature Probe Figure 7 3 7 Refrigerator Tip Out Bin Temp Humidity Sensor ...

Страница 73: ...fference between the two is a different internal address Ensure which sensor is being replaced as the sensors can t have the same address as this will confuse the control board and it will not know which sensor it is talking with 7 5 Door Switch The door switch is a simple reed switch located at the top of the cabinet The actuation magnet should be located in the cutout on the door top trim cover ...

Страница 74: ...ps to overlay 4 Overlay then slides onto door face 5 Attach overlay to door adjustment brackets using remaining 10 x 1 2 screws 6 Once mounted adjust overlay to match adjacent cabinetry 7 Close the door to make adjustments to align panels and reveals 8 For up and down adjustments turn the height adjustment screws in the top bracket see Top of Door illustration Figure 8 2 on page 75 in and out 9 Ad...

Страница 75: ...Column Refrigeration Service Manual Return to Table of Contents 75 8 2 Top Of Door Illustration Figure 8 2 Top Of Door Illustration ...

Страница 76: ...n Service Manual Return to Table of Contents 76 8 3 Door Trim Installation Once overlay is adjusted mount the door trim bracket onto the door adjustment bracket using the provided screws Figure 8 3 Door Trim Installation ...

Страница 77: ...Column Refrigeration Service Manual Return to Table of Contents 77 8 4 Grill Installation Install the grill by snapping into latch catches Figure 8 4 Grill Installation ...

Страница 78: ...Column Refrigeration Service Manual Return to Table of Contents 78 8 5 Toe Kick Clearance Figure 8 5 Toe Kick Clearance ...

Страница 79: ...lower the carbon air filter panel 3 Place the carbon air filter into the holder directly onto the panel and close panel push firmly to engage closure clips 4 It is recommended to replace the carbon air filter every 3 6 months 8 6 2 Ethylene Air Filters Ethylene filters should be placed in the holder in top of the tip out produce bin B 1 Remove the filter from the plastic bag before installing into...

Страница 80: ...abeled position zero 0 and one 1 2 Using a T 20 torx drive turn the fastener approximately 9 to 9 1 2 turns from the zero 0 position to the one 1 position Do not over tighten 2Nm torque max To de activate the hinges move the T 20 torx fastener from position one 1 to position zero 0 by turning the fastener 9 to 9 1 2 turns see figures 8 7 1 and 8 7 2 for activated and deactivated positions CAUTION ...

Страница 81: ...oor drawer frame Feel for a click to indicate the dart is completely seated Install all corners first and then work your way around the perimeter of the door drawer to seat the gasket into its track STEP 4 Finish by going around the gasket once more to feel for any gaps and to ensure the gasket is flat and fully seated 8 9 Replace Door STEP 1 Deactivate Hinges see Section 8 7 STEP 2 Remove Door Tr...

Страница 82: ...at the top of the door by removing the two fasteners See figure 8 9 2 Remove the overlay from the door see Overlay Panel Installation and Adjustments Section 8 1 3 Remove the four 4 fasteners holding the handle to the overlay never over tighten the handle mounting fasteners as this could deform the overlay panel Figure 8 9 Removing door trim cover ...

Страница 83: ...or Catch is bent Door is out of alignment Key will not disengage from lock Lock is not installed properly in the door Key is over rotated Table 8 1 Lock Troubleshooting Column Refrigeration Service Manual Return to Table of Contents 83 8 11 Lock Installation and Troubleshooting To gain access to the lock remove the door trim cover from the top of the door See Figure 8 10 Figure 8 10 Lock Installat...

Страница 84: ...d opening depth Templates for 4 and 6 solid and glass door models can be found on pages 85 88 Reveals between panels can vary 1 8 3mm is the minimum When installing a panel thicker than 3 4 19mm the 90 stop may be required to prevent damage to the unit and adjacent cabinetry As reveals between cabinetry and the unit decrease severe finger pinching can occur while the door is closing Finish sides o...

Страница 85: ...Column Refrigeration Service Manual Return to Table of Contents 85 8 12 1 CR24 Solid Door Template For 4 Toe Kick Figure 8 11 1 CR24 Solid Door Template for 4 Toe Kick ...

Страница 86: ...Column Refrigeration Service Manual Return to Table of Contents 86 8 12 2 CR30 Solid Door Template For 4 Toe Kick Figure 8 11 2 CR30R Solid Door Template for 4 Toe Kick ...

Страница 87: ...Column Refrigeration Service Manual Return to Table of Contents 87 8 12 3 CR24 Solid Door Template For 6 Toe Kick Figure 8 11 3 CR24 Solid Door Template for 6 Toe Kick ...

Страница 88: ...Column Refrigeration Service Manual Return to Table of Contents 88 8 12 4 CR30 Solid Door Template For 6 Toe Kick Figure 8 11 4 CR30 Solid Door Template for 6 Toe Kick ...

Страница 89: ...Column Refrigeration Service Manual Return to Table of Contents 89 8 12 5 CR24 Glass Door Template For 4 Toe Kick Figure 8 11 5 CR24 Glass Door Template for 4 Toe Kick ...

Страница 90: ...Column Refrigeration Service Manual Return to Table of Contents 90 8 12 6 CR24 Glass Door Template For 6 Toe Kick Figure 8 11 6 CR24 Glass Door Template for 6 Toe Kick ...

Страница 91: ...Manual Return to Table of Contents 91 8 12 7 CR24 Screw Zone For Overlay Templates NOTE Hatch areas should provide enough thickness for wood screws for overlay attachment bracket Figure 8 12 1 CR24 Screw Zone For Overlay Templates ...

Страница 92: ...Column Refrigeration Service Manual Return to Table of Contents 92 8 12 8 CR30 Screw Zone For Overlay Templates Figure 8 12 2 CR30 Screw Zone For Overlay Templates ...

Страница 93: ... pull out and rotate down on spring steel stop bracket to disengage stop When stop is disengaged bin will tip out further Once the slides are fully extended remove the slide from the key hole slot on each side of the bin Lift up and pull the bin towards you to disengage the pivot blocks from the pivot fastener See figures 8 13 1 through 8 13 4 ...

Страница 94: ...n the bottom of the cabinet fully open 2 Locate the end fitting on the gas spring on the left side of the bin and using the flat head screwdriver release the end fitting by placing the flat head screwdriver into the release latch and prying outward to disengage the end fitting from the cabinet wall fitting 1 Remove all contents from the tip out bin including glass divider and bottom panel 2 Open t...

Страница 95: ...e of Contents 95 Operation 3 Operation 4 1 Once retainer fasteners are removed tilt the tip out bin up and pull out towards you to remove 1 Using the 5 32 allen wrench remove the left and right shoulder bolts located inside the bottom front of the bin ...

Страница 96: ...elease the end fitting by placing the flat head screwdriver into the release latch and prying outward to disengage the end fitting from the bin wall ball stud 2 Locate the damper end fitting on the right side of the cabinet Using a flat head screwdriver release the end fitting on the damper by placing the flat head screwdriver into the release latch and prying inward to disengage the end fitting f...

Страница 97: ...7 Operation 6 Operation 7 1 Place tip out bin into position by placing left and right guide blocks on bin over pivot bushing in cabinet Allow tip out bin to rest on bottom of cabinet 1 Install left and right shoulder bolts using 5 32 allen wrench and tighten snuggly ...

Страница 98: ...ion 8 Operation 9 1 With the tip out bin rotated all way open install the left side damper onto the cabinet wall fitting by snapping it onto the fitting 1 Pivot tip out bin approximately 45 degrees so right side damper end fitting aligns with bin fitting and snap into place ...

Страница 99: ...frigeration Service Manual Return to Table of Contents 99 Operation 10 1 Check for smooth operation of the tip out bin closing and opening a number of times 2 Re install interior bottom panel and glass dividers ...

Страница 100: ...mechanism on each slide and pull forward on the release mechanisms and pull the drawer out To remove the slide member from the cabinet side wall locate the mounting screws and remove Support the slide to avoid scratching the side wall of the cabinet Reinstallation To reinstall the drawers line up the drawer slide member with the cabinet slide member slide together gently ensuring that the drawer s...

Страница 101: ... avoid scratching the side wall of the cabinet Reinstallation To reinstall the drawers line up the drawer slide member with the cabinet slide member slide together gently ensuring that the drawer slide member is parallel with the cabinet slide member Do not force together as this can result in damage to the ball bearing retainer and result in ball bearings dislodging from the retainer Once engaged...

Страница 102: ... the two retaining pins by prying up using a flat blade screwdriver protect material surfaces to avoid scratches and then pulling the pins out 3 Pull forward on the divider and disconnect the light electrical connection 4 Pull the divider out of the cabinet To install 1 Slide divider into cabinet extrusion 2 Make light electrical connection 3 Manage excess wire and slide divider in until completel...

Страница 103: ...ation To reinstall the shelves first install the cabinet slide assemblies into the pilasters next line up the shelf slide members with the cabinet slide members slide together gently ensuring that the shelf slide member is parallel with the cabinet slide member Do not force together as this can result in damage to the ball bearing retainer and result in ball bearings dislodging from the retainer O...

Страница 104: ...are simple single piece design cantilever shelves Removal To remove simply lift up squarely on the shelf and pull forward to remove from the pilasters Installation To install align shelf brackets with pilasters and slide down into pilaster ensure all for attachment points are engaged Figure 8 18 Freezer Shelving ...

Страница 105: ...scratching the side wall of the cabinet Reinstallation To reinstall the shelves first install the cabinet slide assemblies into the pilasters next line up the shelf slide members with the cabinet slide members slide together gently ensuring that the shelf slide member is parallel with the cabinet slide member Do not force together as this can result in damage to the ball bearing retainer and resul...

Страница 106: ... remove Pull out on the divider and disconnect the light electrical connector Remove divider from the cabinet Installation To install slide divider into cabinet extrusions make light electrical connection manage excess wire and push divider into cabinet until flush with back wall Install retaining fasteners into bottom left and right edges Figure 8 20 1 Dual Zone Compartment Divider Figure 8 20 2 ...

Страница 107: ...e toe kick grill Once the unit is in position height adjustment can be made from the front Using the hex driver leveling tool turn clockwise to raise the unit or counterclockwise to lower See figure 8 21 When the unit is properly leveled door adjustments are less likely to be needed To reduce the possibility of the unit tipping forward the front leveling legs must be in contact with the floor The ...

Страница 108: ... Use an appliance dolly to move the unit near the opening 8 19 Cabinet Anti Tip Anti Tip Bracket To prevent the unit from tipping forward the anti tip bracket must be installed Use all anti tip bracket hardware as instructed Level as instructed on Page 98 prior to installing anti tip bracket s The anti tip bracket and supporting hardware is included with your unit Please note that four anti tip br...

Страница 109: ...ual Return to Table of Contents 109 8 19 1 Anti Tip Installation For Integrated Installation NOTE Do not fasten anti tip brackets to adjacent cabinetry until the cabinet has been leveled Figure 8 22 1 Anti tip Installation Integrated ...

Страница 110: ...vice Manual Return to Table of Contents 110 8 19 2 Anti Tip Installation For Freestanding Installation NOTE Cabinet must be leveled before securing to wall with anti tip bracket Figure 8 22 2 Anti tip Installation Freestanding ...

Страница 111: ...Column Refrigeration Service Manual Return to Table of Contents 111 8 20 Marriage Kit Installation Figure 8 23 1 Marriage Kit Install 1 ...

Страница 112: ...Column Refrigeration Service Manual Return to Table of Contents 112 8 20 Marriage Kit Installation cont Figure 8 23 2 Marriage Kit Install 2 ...

Страница 113: ...Column Refrigeration Service Manual Return to Table of Contents 113 8 20 Marriage Kit Installation cont Figure 8 23 3 Marriage Kit Install 3 ...

Страница 114: ...Column Refrigeration Service Manual Return to Table of Contents 114 8 20 Marriage Kit Installation cont Figure 8 23 4 Marriage Kit Install 4 ...

Страница 115: ...move butter bin lid flex lid in center and pull upwards on one end of lid to disengage lid from pin Slide off opposite end pin To install butter bin lid slide one end over pin and flex center of the lid to slip opposite lid end over pin Figure 8 24 1 Butter Bin 1 Figure 8 24 2 Butter Bin 2 ...

Страница 116: ...Column Refrigeration Service Manual Return to Table of Contents 116 8 22 Trim Kits Figure 8 25 Trim Kit ...

Страница 117: ...geration Service Manual Return to Table of Contents 117 9 0 Replacement Parts 9 1 CR24R CR24D CR24W CC24D CC24W and CR30R Refrigeration Module Figure 9 1 CR24R CR24D CR24W CC24D CC24W and CR30R Refrigeration Module ...

Страница 118: ...Column Refrigeration Service Manual Return to Table of Contents 118 9 2 CR24F Refrigeration Module Figure 9 2 CR24F Refrigeration Module ...

Страница 119: ...Column Refrigeration Service Manual Return to Table of Contents 119 9 3 CR24F Drawers Figure 9 3 CR24F Drawers ...

Страница 120: ...Column Refrigeration Service Manual Return to Table of Contents 120 9 4 CR24R Shelving Figure 9 4 CR24R Shelving ...

Страница 121: ...Column Refrigeration Service Manual Return to Table of Contents 121 9 5 CR30R Shelving Figure 9 5 CR30R Shelving ...

Страница 122: ...Column Refrigeration Service Manual Return to Table of Contents 122 9 6 CR24R CR24F and CR30R Door Figure 9 6 CR24R CR24F and CR30R Door ...

Страница 123: ...Column Refrigeration Service Manual Return to Table of Contents 123 9 7 CR24R and CR30R Drawers Slide Tip Out Bin Figure 9 7 CR24R and CR30R Drawers ...

Страница 124: ...Column Refrigeration Service Manual Return to Table of Contents 124 9 8 Damper Tip Out Bin Figure 9 8 Damper Tip Out Bin ...

Страница 125: ... Refrigeration Service Manual Return to Table of Contents 125 9 9 CR24R CR24D CR24W CR24F CC24D CC24W and CR30R Machine Compartment Figure 9 9 CR24R CR24D CR24W CR24F CC24D CC24W and CR30R Machine Compartment ...

Страница 126: ...Column Refrigeration Service Manual Return to Table of Contents 126 9 10 CR24D CR24W CC24D and CC24W Shelving Figure 9 10 CR24D CR24W CC24D and CC24W Shelving ...

Страница 127: ...Column Refrigeration Service Manual Return to Table of Contents 127 9 11 CR24D CR24W CC24D and CC24W Door Figure 9 11 CR24D CR24W CC24D and CC24W Door ...

Страница 128: ...Column Refrigeration Service Manual Return to Table of Contents 128 9 12 CR24F Column Freezer Figure 9 12 CR24F Column Freezer ...

Страница 129: ...Column Refrigeration Service Manual Return to Table of Contents 129 9 13 CR24R Column Refrigerator Figure 9 13 CR24R Column Refrigerator ...

Страница 130: ...Column Refrigeration Service Manual Return to Table of Contents 130 9 14 CR24D CC24D Dual Zone Wine Column Figure 9 14 CR24D CC24D Dual Zone Wine Column ...

Страница 131: ...Column Refrigeration Service Manual Return to Table of Contents 131 9 15 CR24W CC24W Single Zone Wine Column Figure 9 15 CR24W CC24W Single Zone Wine Column ...

Страница 132: ...Column Refrigeration Service Manual Return to Table of Contents 132 9 16 CR24W CC24W Single Zone Wine Column Shelves Figure 9 16 CR24W CC24W Single Zone Wine Column Shelves ...

Страница 133: ...8300 West Good Hope Road Milwaukee WI 53223 Toll Free 800 558 5592 Fax 414 353 7069 www perlick com Form No Z2551 Rev C 05 03 2019 ...

Отзывы: