Perlick BBRLP Series Скачать руководство пользователя страница 1

Installation & Operation Manual

Commercial Back Bar

•  Remote  & Self-Contained Standard height and low height Models BBR, BBS, 

BBRLP & BBSLP Series

•  Remote & Self-Contained Narrow Door Models BBRN & BBRSN Series
•  Remote & Self-Contained Pass Thru Models PTR & PTS Series
•  Remote & Self-Contained Sliding Door Models SDB & SDP Series
•  Self-Contained Dual-Zone DZS Series Concessionaire
•  Direct Draw DDC & DDS Series

Form No. Z2604

Rev A 11.24.2020

Model BBSLP108 Shown

Содержание BBRLP Series

Страница 1: ... BBRLP BBSLP Series Remote Self Contained Narrow Door Models BBRN BBRSN Series Remote Self Contained Pass Thru Models PTR PTS Series Remote Self Contained Sliding Door Models SDB SDP Series Self Contained Dual Zone DZS Series Concessionaire Direct Draw DDC DDS Series Form No Z2604 Rev A 11 24 2020 Model BBSLP108 Shown ...

Страница 2: ...ation in the manual The information is important for the safe and efficient installation operation and care of your Perlick unit DANGER Indicates a hazard that WILL result in serious injury or death if precautions are not followed WARNING Indicates a hazard MAY cause serious injury or death if precautions are not followed CAUTION Indicates a hazard where minor or moderate injury may occur if preca...

Страница 3: ...he unit Larger units may require additional personnel 3 Before moving unit secure door s to unit with tape to prevent from opening 4 Carefully move unit to installation site and place in front of opening CAUTION Finished flooring should b e p r o t e c t e d w i t h appropriate material to avoid damage from moving the unit Plumbing CAUTION Do not over tighten drain fitting or damage to the threads...

Страница 4: ... finished floor Protect a finished floor with plywood cardboard or some other suitable material before moving the unit into place Failure to do this may result in damage to the floor NOTE If unit has been laid on its back or sides place unit upright and allow minimum of 24 hours before connecting to a power source Failure to follow this procedure may damage the compressor and void warranty 1 Make ...

Страница 5: ...lectric condensate pan can be installed underneath the cabinet to collect and evaporate the condensate from the cabinet evaporator A 6 3 prong plug is included Aseparate circuit should be provided for the heater The kit can be used only on cabinets equipped with 4 minimum legs it cannot be used on units equipped with platform or base plate kits Follow instructions supplied with the kit Base Plate ...

Страница 6: ...mperature Beer will freeze at temperatures lower than 30 F When beer freezes the alcohol in the beer may separate and cause the beer to be cloudy with an off taste The following chart shows how temperature affects beer Checking Product Temperature 1 To accurately check the temperature of product stored in the refrigerated compartment insert an accurate thermometer into a plastic unbreakable bottle...

Страница 7: ...inge Kit from Perlick Plastic putty knife Procedure 1 Support the door in the open position as shown in Figure 3 Remove the hinge pin 2 Pull door to the side and then lower the door 3 Remove top and bottom hinge brackets Retain screws for later use See Figure 4 4 Remove the hole plugs from the top and bottom hinge bracket mounting holes Figure 4 Place the plug in the holes on the opposite side mad...

Страница 8: ...ng screws removed in step 6 Figure 9 11 Place lower V block into lower cabinet hinge with notch parallel to cabinet Figure 10 6 Remove the top and bottom hinge brackets from the door Figure 6 Retain the screws for later use 7 Removethefrontpanelfromthedoorassembly by removing the inner mounting screws 4 per side from the perimeter of the door assembly Figure 7 Rotate the front panel 180 The top be...

Страница 9: ...ckets at desired location and reinstall shelf s Drawer Dividers Adjustment See Figure 13 CAUTION Completely empty shelf or drawer before removing Lift divider straight up and move to desired position engaging tabs in holes Make sure divider tabs engage corresponding holes on both sides Figure 10 Installing V Block Figure 11 Installing Door Figure 13 Drawer Divider Adjustment Figure 12 Shelf Bracke...

Страница 10: ...ach door To increase or decrease spring tension remove the Phillips screw and position the bracket in one of three detentes and reinstall screw The detente farthest to the left creates the least amount of tension NOTE Units are shipped from the factory with springs set at the weakest settings Sliding Door Lock Each set of sliding doors is equipped with a keyed lock located on the bottom of the rig...

Страница 11: ...awer See Figure 15 CAUTION Completely empty drawer before removing 1 Pull the drawer out to its furthest position Locate the latch in the middle of both extenders Push each latch forward and lift front of latch up unlocked position then lift the front of the drawer and pull out Installing Drawer 1 Place drawer on to the extenders making sure wheels engage the slots on each side 2 Push drawer all t...

Страница 12: ...ontact your cleaner supplier If your present cleaner contains chlorides ask your supplier if they have an alternative Avoid cleaners containing quaternary salt it also can attack stainless steel and cause pitting and rusting Keep food equipment clean Use alkaline chlorinated or non chloride cleaners at recommended strength Clean frequently to avoid build up of hard stubborn stains The single most ...

Страница 13: ...ng only a small amount of cleanser Rinse with water and dry Heat tint or heavy discoloration Penny Brite Copper Brite Paste Nu Steel Dubois Temp or Tarnite Rinse and rub onto surface with a dry cloth Bar Keepers Friend Revere Stainless Steel Cleaner Allen Polish Steel Bright Wyandotte Bab O or Zud When using these cleaners apply with a damp sponge or cloth rinse thoroughly and wipe dry Tenacious d...

Страница 14: ... recheck temperature Reset preset temperature if necessary Make sure louvers and or fan is not obstructed System runs for long period of time Condenser dirty or obstructed Door kept open for long time or opened more frequently Warm product place in cabinet recently Hot day and warm room temperature Clean condenser and clear obstruction Wait 24 hours and recheck temperature Reset preset temperature...

Страница 15: ...Center Inquire via the web at www perlick com or call 800 558 5592 Genuine Perlick replacement parts and accessories have been tested and approved for use with flammable refrigerants to prevent hazardous conditions For Product Information Contact your selling dealer Inquire via the web at www perlick com Call 800 558 5592 for factory assistance on planning installation or product information Write...

Страница 16: ...Commercial Back Bar Installation Operation Manual 16 DIMENSIONS ...

Страница 17: ...Commercial Back Bar Installation Operation Manual Form No Z2604 Rev A 11 24 2020 ...

Страница 18: ...Commercial Back Bar Installation Operation Manual 18 ...

Страница 19: ...28 25 7 16 647 R23 3 8 593 23 584 10 3 8 263 13 16 21 1 1 8 29 2 OPTIONALFLOOR ACCESS KIT 51 6 1 4 159 17 432 18 3 4 476 20 508 BBSLP36 44 1118 BBSLP60 68 1727 BBSLP84 92 2337 BBSLP108 3 4 NPT DRAIN EXIT 26 5 16 668 UNIT CONDENSING OPPOSITE ACCESS REMOVABLE 51 89 3 1 2 21 3 4 553 2 1 1 16 26 119 4 11 16 629 24 3 4 DOORS 1 13 16 46 7 8 22 DOORS RELEASE FOR PRODUCTION 2 2 B A 3 C B A 1 C 1 3 ANGULAR...

Страница 20: ...161 2 51 36 914 23 584 R23 3 8 593 2 51 OPTIONAL FLOOR ACCESS 37 3 4 958 BBRLP48 42 3 4 1085 BBRLP72 BBRLP96 18 3 4 476 BACK LINER TO INSIDE DOOR SILL 7 3 4 196 1 NPS DRAIN ACCESS 4 3 4 120 6 1 4 160 5 128 6 1 4 158 44 1118 BBRLP48 68 1727 BBRLP72 92 2337 BBRLP96 25 7 16 647 20 3 4 527 9 1 16 230 3 3 8 85 RELEASE FOR PRODUCTION 2 2 B A 3 C B A 1 C 1 3 ANGULAR FRACTIONS SW J Dwg 95000 95318 slddrw ...

Страница 21: ...Commercial Back Bar Installation Operation Manual Form No Z2604 Rev A 11 24 2020 ...

Страница 22: ...Commercial Back Bar Installation Operation Manual 22 ...

Страница 23: ...Commercial Back Bar Installation Operation Manual Form No Z2604 Rev A 11 24 2020 ...

Страница 24: ...Commercial Back Bar Installation Operation Manual 24 ...

Страница 25: ...Commercial Back Bar Installation Operation Manual Form No Z2604 Rev A 11 24 2020 ...

Страница 26: ...Commercial Back Bar Installation Operation Manual 26 ...

Страница 27: ...Commercial Back Bar Installation Operation Manual Form No Z2604 Rev A 11 24 2020 ...

Страница 28: ...Commercial Back Bar Installation Operation Manual 28 ...

Страница 29: ...Commercial Back Bar Installation Operation Manual Form No Z2604 Rev A 11 24 2020 ...

Страница 30: ...Commercial Back Bar Installation Operation Manual 30 ...

Страница 31: ...Commercial Back Bar Installation Operation Manual Form No Z2604 Rev A 11 24 2020 ...

Страница 32: ...STERS DOOR OPENING 19 7 8 504 X 68 1727 DDC68 TEE TOWER 92 2337 DDC92 12 3 4 325 DRAGT ARM OR 23 3 4 603 1 NPS DRAIN ACCESS 813 DDC92 ONLY 32 363 14 1 4 24 610 4 3 4 120 22 3 4 578 809 1 13 16 46 31 7 8 629 24 3 4 34 9 16 878 40 9 16 1031 7 8 22 627 24 11 16 6 153 POWER CORD EXIT RECESSED 1 1 8 29 BACK VIEW 53 2 1 16 403 15 7 8 3 1 16 78 6 152 DDC92 WITH TEE TOWERS DDC68 WITH DRAFT ARM 95181 REV D...

Страница 33: ...OPENING 19 7 8 504 X 28 1 8 714 603 TEE TOWER 12 3 4 325 DRAFT ARM OR 23 3 4 36 914 DDS36 60 1524 DDS60 84 2134 DDS 84 108 2743 DDS 108 24 610 DDS84 WITH TEE TOWERS POWER CORD EXIT RECESSED 1 1 8 29 152 6 78 3 1 16 53 2 1 16 15 7 8 403 DDS60 WITH TEE TOWER 48 1219 DDS108 WITH DRAFT ARMS 3 4 NPT DRAIN EXIT 119 4 11 16 22 3 4 578 34 9 16 878 629 24 3 4 809 31 7 8 7 8 22 1 13 16 46 1 1 16 26 1 NPS DR...

Страница 34: ...Commercial Back Bar Installation Operation Manual 34 WIRING DIAGRAMS BBR24 BBRN40 57342A 99 120 RevA ...

Страница 35: ...Commercial Back Bar Installation Operation Manual Form No Z2604 Rev A 11 24 2020 BBR48 BBRN60 BBR72 BBRN80 BBR96 57342A 98 120 RevA ...

Страница 36: ...Commercial Back Bar Installation Operation Manual 36 BBRLP 95322A 120 RevA ...

Страница 37: ...Commercial Back Bar Installation Operation Manual Form No Z2604 Rev A 11 24 2020 WHITE RED WHITE WHITE WHITE RED RED RED CONTROLLER SWITCH BBS BBSN 57342C 97 120 ...

Страница 38: ...Commercial Back Bar Installation Operation Manual 38 SWITCH RED RED RED WHITE RED CONTROLLER WHITE WHITE BBSLP 95321C 120 ...

Страница 39: ...Commercial Back Bar Installation Operation Manual Form No Z2604 Rev A 11 24 2020 WHITE RED WHITE WHITE WHITE RED RED RED CONTROLLER SWITCH DDS DDC 57342C 100 120 ...

Страница 40: ...Commercial Back Bar Installation Operation Manual 40 DZS36 57342B 108 ...

Страница 41: ... Rev A 11 24 2020 WHT NO RED RED SENSING PROBE OUTPUT RED FRONT OF UNIT RED CONNECT TO RED CONNECT TO WHT WHT RED RED FRONT OF UNIT WHT WHT WHT RED COIL CONTROLLER SWITCH RED RED RED WHITE RED WHITE RED CONTROLLER SENSING PROBE INPUT C WHITE WHITE DZS60 57342B 107 ...

Страница 42: ...tion Operation Manual 42 SWITCH RED RED OUTPUT INPUT RED WHITE WHITE WHITE WHITE RED RED WHITE WHITE POWER CONNECTION PRESSURE SWITCH NOTE WHITE SWITCH RED RED PRODUCTION START 04 20 2020 PRODUCTION END NA PTR 57342A 102 120 RevA ...

Страница 43: ...ion Operation Manual Form No Z2604 Rev A 11 24 2020 SWITCH CONTROLLER WHITE RED RED WHITE WHITE RED RED WHITE WHITE RED WHITE SWITCH RED RED WHITE RED WHITE UNIT HERE PRODUCTION START 04 20 2020 PRODUCTION END NA PTS 57342C 101 120 ...

Страница 44: ...Commercial Back Bar Installation Operation Manual 44 SDBR48 SDBR96 57342A 106 120 RevA ...

Страница 45: ...Commercial Back Bar Installation Operation Manual Form No Z2604 Rev A 11 24 2020 SWITCH RED RED WHITE RED WHITE CONTROLLER WHITE WHITE SDBS 57342C 105 120 ...

Страница 46: ...Commercial Back Bar Installation Operation Manual 46 SDPR 57342A 104 120 RevA ...

Страница 47: ...Commercial Back Bar Installation Operation Manual Form No Z2604 Rev A 11 24 2020 WHITE CONTROLLER RED SWITCH RED WHITE WHITE WHITE RED RED SWITCH SDPS 57342C 103 120 ...

Страница 48: ...term or condition except as provided in writing nor as a waiver of any subsequent breach of the same term or condition METHOD OF SHIPMENT All shipments are carefully packed and labeled Crates boxes and cartons used are of approved weight and strength Freight rates are based upon 100 pound minimum LOST and DAMAGED MERCHANDISE THE RESPONSIBILITY OF THE PERLICK CORPORATION CEASES UPONACCEPTANCE OF IT...

Страница 49: ...sales are the responsibility of the user ONE YEAR LABOR WARRANTY In addition to Perlick s one year parts warranty and five year compressor warranty ALL PERLICK REFRIGERATION SYSTEMS are offered with a one year labor warranty at no extra charge Perlick s one year labor warranty provides that Perlick will pay for the cost of any labor to replace any defective part for up to one year after installati...

Страница 50: ...NOTES ...

Страница 51: ...NOTES ...

Страница 52: ...8300 West Good Hope Road Milwaukee WI 53223 Toll Free 800 558 5592 Fax 414 353 7069 www perlick com Z2604 ...

Отзывы: