Back Bar Operation Installation Manual
Return to
28
STEP 1.
STEP 2.
STEP 3.
STEP 4.
STEP 5.
STEP 1.
STEP 2.
STEP 3.
STEP 4.
STEP 5.
STEP 6.
STEP 7.
STEP 8.
6.10 Replace Condenser Fan Motor
Remove Refrigeration Deck. See Section 6.2.
Unplug the fan power cord from beneath electrical
box on compressor.
Remove fan motor assembly by removing 4 Phillips
head screws that hold the fan bracket.
Figure 6-9. Fan Mounting Hardware
Install new fan motor assembly by attaching the
bracket with 4 screws.
Install refrigeration deck by reversing steps in sec-
tion 6.2.
6.11 Replace Evaporator Fan Motor –
Self-Contained Models
Remove grille by removing 3 Phillips head screws,
one at the top center and two at the bottom edge.
Cut 2 zip ties holding wire harness to top of the
refrigeration module.
Disconnect evaporator fan wire leads from main
wiring harness.
Remove sealing compound from top and bottom of
wire pass-through located inside evaporator box and
inside of machine compartment.
Remove shelving from unit, as well as shelf bracket
on left wall.
Remove 7 screws holding evaporator fan panel to
unit. Figure 8-7
Tip evaporator fan assembly down and remove
from unit. Pull evaporator fan wires up though the
top of the machine compartment.
Remove 8 screws to separate front and back of
evaporator fan panel.
Содержание BBR96
Страница 8: ...Back Bar Operation Installation Manual Return to Table of Contents 8...
Страница 65: ...65 Return to Table of Contents Back Bar Operation Installation Manual 9 3 Refrigeration Module DZS Model Series...
Страница 74: ...Back Bar Operation Installation Manual Return to Table of Contents 74 NOTES...
Страница 75: ...75 Return to Table of Contents Back Bar Operation Installation Manual NOTES...
Страница 76: ...8300 West Good Hope Road Milwaukee WI 53223 Toll Free 800 558 5592 Fax 414 353 7069 www perlick com...