P/N 5500444-10 (Rev F) 

 

 

   

Perle Type 4 High-Power PoE  

 10/100/1000 Ethernet  

               Media Converters

 

Installation Guide 
 

S-1110HP 

S-1110HP-XT 

S-1110HP-SFP 

S-1110HP-SFP-XT 

S-1110DHP 

S-1110DHP-XT 

S-1110DHP-SFP 

S-1110DHP-SFP-XT 

S-1110HP-DSFP 

S-1110HP-DSFP-XT 

S-1110DHP-DSFP 

S-1110DHP-DSFP-XT 

 
 

 

Содержание S-1110DHP

Страница 1: ...h Power PoE 10 100 1000 Ethernet Media Converters Installation Guide S 1110HP S 1110HP XT S 1110HP SFP S 1110HP SFP XT S 1110DHP S 1110DHP XT S 1110DHP SFP S 1110DHP SFP XT S 1110HP DSFP S 1110HP DSFP...

Страница 2: ...er Extended Temperature models have a terminal block adapter and do not come with a power adapter or cable Non Extended Temperature models come with a power adapter and cable S 1110HP 120 watts S 1110...

Страница 3: ...ents Seul le personnel qualifi doit connecter l alimentation cet appareil Cautions and Warnings Warning Power sources must be off prior to beginning the power connection steps Read the installation in...

Страница 4: ...connexion d alimentation Lisez les instructions d installation avant de connecter l appareil sa source d alimentation Attention L alimentation lectrique de l quipement doit tre valu e de mani re appr...

Страница 5: ...as connect s Ne pas regarder fixement le faisceau ou de visualiser le faisceau directement avec des instruments optiques Le nonrespect de cet avertissement pourrait entra ner une blessure l il ou la c...

Страница 6: ...models are compatible with Powered Devices that comply with the IEEE 802 3af standard 802 3at 2009 standard and the IEEE 802 3bt standard for High Power PoE devices The fiber connection can be either...

Страница 7: ...ngth TX RX nm S 1110DHP SC05 S 1110DHP ST05 SC ST MM 550 m 1804 ft 850 S 1110DHP SC05U S 1110DHP SC05D SC MM 500 m 1804 ft 1310 1550 1550 1310 S 1110DHP SC2 S 1110DHP ST2 SC ST MM 2 km 1 2 mi 1310 S 1...

Страница 8: ...SC05 XT S 1110HP ST05 XT SC ST MM 550 m 1804 ft 850 S 1110HP SC10 XT S 1110HP ST10 XT SC ST SM 10 km 6 2 mi 1310 S 1110HP SC10U XT S 1110HP SC10D XT SC SM 10 km 6 2 mi 1310 1490 1490 1310 S 1110HP SFP...

Страница 9: ...the DIP switch settings if required 5 Install and connect the fiber cable s 6 Install and connect the copper cable s 7 Power up the media converter Auto MDIX Jumper Settings Note The factory settings...

Страница 10: ...High Power PoE Ethernet Media Converter Installation Guide Note The default jumper setting is AUTO DIP Switches The DIP switches are accessible through the opening in the side of the enclosure Bank 1...

Страница 11: ...y be turned off if the copper link partner does not support Auto Negotiation and fixed settings are required by the copper link partner Copper port 2 only supports Auto negotiation Auto The media conv...

Страница 12: ...copper port can occur without affecting the other connection Smart Link Pass Through The link state on one connection is directly reflected through the media converter to the other connection If link...

Страница 13: ...ransmit or receive line will be passed through to the local copper connection thus notifying the connected device If the media converter has been set to Smart Link Pass Through mode the effect will be...

Страница 14: ...n its receiver 2 A Sends FFA 3 B Detects FFA signal and shuts down the fiber link 4 B Drops link on copper connection because Smart Link Pass Through is configured 5 A Link on copper connection is not...

Страница 15: ...Mbps Up default Auto Auto Down Off Auto Auto The Media Converter will negotiate Ethernet parameters on the fiber connection This will ensure that the most optimal connection parameters will be in effe...

Страница 16: ...transmit TX fiber connection The data link will be disabled however power to the powered devices will be maintained This mode will override all other switch settings Note On media converters with two...

Страница 17: ...will turn off PSE output power to the PD device connected to copper port 1 and or 2 After 2 seconds the media converter will restore power to the PD and the power will remain on until one of the fibe...

Страница 18: ...remains so for 6 seconds fiber port 1 will be re activated and fiber port 2 will be put back into stand by mode Both Perle media converters must have switch 8 down enabled Installing the SFP Fiber Mod...

Страница 19: ...ctors Ensure that the TX wavelength matches the RX wavelength at the other end and the RX wavelength matches the TX wavelength at the other end 2 Connect the fiber cable from one media converter to th...

Страница 20: ...talled first and disconnected last Attaching the Grounding Lug 1 Attach the grounding lug to one end of an 18 12 AWG wire 2 Attach the grounding lug to the chassis and secure with the grounding screw...

Страница 21: ...Media Converter if attached 3 Strip both wires 5mm 3 16th inch 4 Loosen the terminal block screws and connect Positive wire to the left terminal Connect the Negative wire to the right terminal Tighten...

Страница 22: ...On failure See LED Pattern to determine pattern combination and failure cause LED Pattern FDF LKF FDC PSE Off Off On On SFP incompatible All other LED patterns Internal hardware failure FDF 1 2 Fiber...

Страница 23: ...r link up and receiving data PSE 1 2 Solid Green Active The PSE has successfully detected a compliant PD and is applying power over the UTP Solid Yellow Inactive The PSE is not active The PSE has been...

Страница 24: ...d automatically configures the connection Pause IEEE 802 3xy Integrated Pause signalling is an IEEE feature that temporarily suspends data transmission between two devices in the event that one of the...

Страница 25: ...nnectivity with all DIP switches in the UP position this procedure is recommended for troubleshooting Method 1 1 Set the Link Mode to Standard on both media converters Leave all other switches in the...

Страница 26: ...emote media converter At the remote media converter the data will be looped back and passed through the fiber back to the local converter and passed to the copper link No Power to the PD 1 Ensure that...

Страница 27: ...158 F 40 C to 85 C 40 F to 185 F Operating Humidity 5 to 90 non condensing Storage Humidity 5 to 95 non condensing Operating Altitude Up to 3 048 m 10 000 ft Dimensions 150 mm by 96 mm by 26 mm Safet...

Страница 28: ...oE PDs Type 2 High Power HP Support for type 3 and 4 devices Single and double signatures PoE Specifications Standard IEEE802 3af IEEE802 3at IEEE802 3bt IEEE802 3bt PSE Type Type 1 Type 2 Type 3 Type...

Страница 29: ...3 14 S 1110HP SC40 S 1110HP ST40 SM TX 1310 RX 1310 Min 3 Max 5 Min 23 Max 3 20 S 1110HP SC40U S 1110HP SC40D SM TX 1490 1310 RX 1310 1490 Min 8 Max 3 Min 22 Max 3 14 S 1110HP SC70 S 1110HP ST70 SM T...

Страница 30: ...110DHP SC10U S 1110DHP SC10D SM TX 1310 1490 RX 1490 1310 nm Min 9 Max 3 Min 20 Max 3 11 S 1110DHP SC20U S 1110DHP SC20D SM TX 1310 1490 RX 1490 1310 Min 8 Max 3 Min 22 Max 3 14 S 1110DHP SC40U S 1110...

Страница 31: ...gle fiber Mode Wavelength TX RX TX Power DB RX Power DB Budget S 1110DHP SC05 XT S 1110 DHP ST05 XT MM TX 850 RX 850 Min 9 5 Max 4 Min 17 Max 3 7 5 S 1110DHP SC10 XT S 1110DHP ST10 XT SM TX 1310 RX 13...

Страница 32: ...n be found at http www perle com support_services warranty shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Techni...