291
Channels
Field Descriptions
Configure the following parameters:
Description
Provide a description of the channel, making it easier to identify.
Data Options:
Maximum 20 characters, including spaces
Input Mode
When selected, the channel will be reading the status of the line (input). The
internal jumpers must match the software configuration; the internal jumpers
are factory configured for
Input Mode
.
Default:
Input Mode
Latch
Latches (remembers) the activity transition (active to inactive or inactive to
active).
Data Options:
None, Inactive-to-Active, Active-to-Inactive
Default:
None
Invert Signal
When enabled, inverts the actual condition of the I/O signal in the status;
therefore, an inactive status will be displayed as active.
Default:
Disabled
Trigger
When the trigger condition is met, triggers the specified alarm action.
Data Options:
z
Disabled
—No alarm settings. This is the default.
z
Inactive
—When the expected Digital input is active, going inactive will
trigger an alarm.
z
Active
—When the expected Digital input is inactive, going active will
trigger an alarm.
Default:
Disabled
Содержание IOLAN MDC
Страница 1: ...1 IOLAN SDS SCS STS MDC User s Guide Version A1 12 06 2017 Part 5500161 47 Rev I June 2017...
Страница 3: ...3...
Страница 115: ...111 WLAN Security Encryption...
Страница 386: ...382 Configuring a Virtual Private Network...