7
IDS-509CPP Hardware Installation Guide
Ports
10/100/1000Base-T Ports with PoE/PoE+ capability
These ports provide the standard gigabit Ethernet interface. They provide speeds of 10/
100 or 1000 Mb/s through twisted pair (UTP) cables of up to 100 meters (328ft) in length.
Ports 1 through 8 can provide power to PoE/PoE+ PD devices. Ports 5, 6 and 7 can be
used as Combo ports.
100/1000 Mb/s SFP Slots
The SFP slots can accommodate industry standard SFP’s from Perle or other suppliers.
These SFP’s can be 100 or 1000 Mb/s or can be SGMII models including 1000Base-T
Copper SFP’s. SFP ports labeled as 5, 6 and 7 can be used as Combo ports.
Combo ports (Dual)
Through configuration or through auto-detection Combo ports provide two physical port
options for one logical switch port. A link may be established on either the SFP module
inserted in the slot or on the 10/100/1000Base-T port associated with it. If both ports are
occupied (Ethernet and SFP module), the SFP module will take priority. Combo ports are
labeled as 5, 6, 7 on the RJ45 and 10/100/1000Base-T ports/slots respectively.
RJ45 Console Port
This is a console management port providing access to the switch management function
using the industry standard CLI command set. This port has an RJ45 connector.
See RJ45 Console Port Pinouts.
USB Console Port
The MicroUSB port is an alternative connection to the switch’s console. This provides
access to the switch management function using the industry standard CLI command set.
When connected the port presents a serial interface that can be used from a PC Terminal
emulation program (such as PuTTY).
Power Connector
The power input connector has provisions for dual inputs. Two independent power
sources can be used to power the switch. If one power input fails, the other power input
will power the switch.
Alarm Relay Connector
The Alarm Relay can be energized by the software or hardware under certain conditions.
It can then be used to trigger an external alarm circuit such as a light or sounding device.
This connector provides both Normally opened (NO) and Normally Closed (NC) dry con-
tact on the connector block, both are associated with the same relay.
Digital Input Connector
Two Digital Inputs are provided that can be used for the generation of alarms (SNMP trap,
energizing of on board Alarm Relay etc.).