background image

 

Perle 10GT  

    Media Converter 

Modules 

 

 

Installation Guide 

C-10GT-SFP 

CM-10GT-SFP 

C-10GT-XFPH 

CM-10GT-XFPH 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P/N 5500337-10 

Содержание C-10GT-SFP

Страница 1: ...Perle 10GT Media Converter Modules Installation Guide C 10GT SFP CM 10GT SFP C 10GT XFPH CM 10GT XFPH P N 5500337 10...

Страница 2: ...r XFP up to power level 4 These modules take two slots within a Perle Media Converter chassis The C model modules are the unmanaged modules and the CM models are the managed modules For information on...

Страница 3: ...llation Guide 3 Getting to know your C CM 10GT Media Converter Your C CM 10GT Media Converter package consists of the following items C CM 10GT module with one transceiver port SFP or XFP and one RJ 4...

Страница 4: ...uto detection These are the steps required to configure the Perle C CM 10GT module 1 Set the Auto Jumper switch optional 2 Set the DIP switch settings optional 3 Install the module into the chassis Se...

Страница 5: ...the Built In Link Tests Note The Operation Mode Switch 1 affects the function of DIP Switches 2 and 3 when in Test mode Link Mode Switch 2 Data Mode Switch Position Mode Up default Smart Link Pass Thr...

Страница 6: ...dia converter module then the remote media converter module will automatically be put into test mode Note The BILT can operate on 10G modules This feature can also be used with Perle S 10G media conve...

Страница 7: ...ocal C CM media converter module 5 If the PWR LED on the Local C CM media converter module blinks red this connection may require further testing The PWR LED should flash green to indicate that there...

Страница 8: ...nts 1 Media Converter Module A loses fiber connection RX 2 Media Converter Module A notifies the remote Media Converter Module that there is a fault on the Link 3 Media Converter Module B detects loss...

Страница 9: ...ing mode 2 Gently slide the module into the slot until it becomes flush with the front of the chassis Light pressure may be needed to seat the module Do not force the module as you might damage the mo...

Страница 10: ...al flash memory to see if configuration information has been downloaded to it from a management module If so it will use this configuration as its running configuration If there is no configuration in...

Страница 11: ...faceplate of the module PWR Power Test Green On Power is on and the module is in normal operation mode Green blinking slowly the module is in test or loopback mode Red blinking slowly while in Test m...

Страница 12: ...Port 2 Activity On Copper link present Blinking quickly Copper link present and receiving data Blinking slowly The copper link has been taken down as a result of Smart Link Pass Through Blinking one...

Страница 13: ...the link to generate the test data master side and one side to receive and analyse the test data slave side 1 Set Switch 1 down and Switch 2 to the Up position Built In Link Test on the master side 2...

Страница 14: ...ta received on the receiver RX will be looped back to the transmitter TX connection Use a third party application to analyse the received data Module Temperature Protection All C CM 10GT modules come...

Страница 15: ...Max 1 25A at 12VDC Operating Temperature 40 C 75 C 40 F 167 F Storage Temperature 40 C 85 C 40 F 185 F Operating Humidity 5 to 90 non condensing Storage Humidity 5 to 95 non condensing Operating Alti...

Страница 16: ...rference at his her own expense EN 55022 Class A WARNING This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take ad...