P/N 5500326-10
Perle 10G
Media Converter
Modules
Installation Guide
CM-10G-STS
C-10G-STS
CM-10G-XTS
C-10G-XTS
CM-10G-XTX
C-10G-XTX
CM-10G-XTSH
C-10G-XTSH
CM-10G-XTXH
C-10G-XTXH
Страница 1: ...P N 5500326 10 Perle 10G Media Converter Modules Installation Guide CM 10G STS C 10G STS CM 10G XTS C 10G XTS CM 10G XTX C 10G XTX CM 10G XTSH C 10G XTSH CM 10G XTXH C 10G XTXH ...
Страница 2: ...s support low power transceivers whereas the Cx 10G XTSH and Cx 10G XTXH support high power power level 4 transceivers The high power modules take two slots within a Perle Media Converter chassis All combination of modules within the chassis cannot exceed the chassis power input consumption The full power consumption for Perle Media Converter chassis can be found on the Perle website Note The Cx 1...
Страница 3: ... transceiver ports This guide Cx 10G Front View Installation The default switch settings all switches in the UP position will work for most installations The default Auto Jumper is set to Auto These are the steps required to configure the Perle 10G Media Converter module 1 Set the Auto Jumper switch optional 2 Set the DIP switch settings optional 3 Install the module into the chassis See Installin...
Страница 4: ...Installation Guide 4 4 Insert appropriate modules into the pluggable transceiver ports 5 Connect fiber or copper cables to the installed modules 6 The Media Converter module is automatically powered up Cx 10G STS Cx 10G XTS Cx 10G XTSH ...
Страница 5: ... Do not force the module as you might damage the module If there is resistance remove the module and check the module s backplane connector for damage to the pins If the module s backplane connector is not damaged try to reinsert the module again 3 Tighten the Captive retainer screw to ensure the module is locked in place Caution Observe electrostatic discharge precautions when installing or remov...
Страница 6: ...nfiguration as its running configuration If there is no configuration in flash it will read the settings of the DIP switches and use those as its running configuration SW When set to SW Switch the module will at power up read the settings of the DIP Switches and use those as its running configuration It will ignore any configuration information in its flash memory NOTE The default jumper setting i...
Страница 7: ...nk Mode Switch 2 Data Mode Switch Position Mode Up default Smart Link Pass Through Mode Down Standard Mode Smart Link Pass Through In this mode the link state on one connection is directly reflected through the Media Converter module to the other connection If fiber link is lost on one of the connections then the other fiber link will be brought down by the Media Converter module Standard Mode In ...
Страница 8: ...tterns to be sent out the selected port to the remote media converter module If the remote media converter module is a supported Perle media converter module the port will automatically be put into loopback mode Loopback If Switch 2 is down the specified port will be put into loopback mode In this mode the port will be ready to receive the test patterns generated by another Perle media converter m...
Страница 9: ...back mode 2 The remote media converter module turns on loopback mode 3 Built In Test Data is sent from the Local Cx 10G media converter module to the Remote media converter module 4 The Remote media converter module loops the received data back to the Local Cx 10G Media Converter module 5 Any test errors detected are displayed with the LEDs on the front of the Local Cx 10G Media Converter module 6...
Страница 10: ...n either the transmit or receive line will be passed through to the other fiber connection Disabled The Media Converter will not monitor for fiber fault Illustration of the FFA feature Media Converter A Configuration Link Mode Standard Mode Fiber Fault Alert Media Converter B Configuration Link Mode Smart Link Pass through Mode Fiber Fault Alert Sequence of Events 1 Media Converter A loses fiber c...
Страница 11: ...Down Off On When AutoDetect Mode is turned On the Cx 10G media converter module will establish the linear or limiting settings based on the contents of the EPROM on the module and module type Off When AutoDetect Mode is turned OFF the Cx 10G media converter module will select the alternative setting from that established by the determination above ...
Страница 12: ...n During power up hardware error detected Red Blinking Error detected See LK1 LK2 Error Codes Red Solid or blinking A module has been inserted that is requesting more than the specified maximum power for that port LK1 Port 1 Activity On Fiber link present Blinking quickly Fiber link present and receiving data Blinking slowly The fiber link has been taken down as a result of Smart Link Pass Through...
Страница 13: ...unicate with module On On Internal Error Troubleshooting General Ensure power is supplied to the media converter use of the Perle supplied power adapter is highly recommended Ensure that SFP or XFP modules are of the same speed and are operating properly Ensure both devices on either end of each fiber are compatible Ensure all cabling is of the correct type and is in good operating condition For f...
Страница 14: ...nue to monitor the modules temperature until the temperature is below the maximum operating temperature and then the Cx 10G will return the module s to normal operating mode Loopback Auto Detect Perle Cx 10G media converter modules have the ability to automatically put remote supported Perle media converter modules into loopback mode This allows the remote Perle media converter module to be locate...
Страница 15: ...ge Humidity 5 to 95 non condensing Operating Altitude Up to 3 048 m 10 000 ft Weight 0 15 kgs 0 3 lbs Module Support MSA compliant SFP MSA complaint Class 1 2 and 3 XFP modules for the Cx 10G XTX models and Cx 10G XTS models MSA complaint Class 1 2 3 and 4 XFP for the Cx 10G XTXH and Cx 10G XTXSH models 1G copper modules 1G fiber modules SFP supports Cx1 direct attach interfaces XFP supports Cx4 m...
Страница 16: ...terference at his her own expense EN 55022 Class A WARNING This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures EN 55024 Class A Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical Support Query may be made ...