Part# 5500332-11 (Rev A) 

Version: A.1.10.01.2017 

 

 

Perle  

Advanced Powered 

Ethernet Extenders 

Installation Guide 

 

10/100    

10/100/1000(Gigabit) 

 

eXP-xS110L  

eXP-xS1110L 

 

 

 

eXP-xS110E  

eXP-xS1110PE  

 

 

 

eXP-xS1110E 

 

 

                                                                            
 

Содержание 06004920

Страница 1: ...Part 5500332 11 Rev A Version A 1 10 01 2017 Perle Advanced Powered Ethernet Extenders Installation Guide 10 100 10 100 1000 Gigabit eXP xS110L eXP xS1110L eXP xS110E eXP xS1110PE eXP xS1110E...

Страница 2: ...would power the E model via the VDSL line L Models Characteristics The L models such as the eXP 4S1110L RJ are typically used in the central location and have the following characteristics Can provide...

Страница 3: ...3 Installation Front Panel View Back Panel View...

Страница 4: ...es for more information 2 Set Power Sourcing Jumpers If needed E and PE models only 3 Connect Line cables to the Line ports See Connecting to the Line Port for more information If using VDSL Line Powe...

Страница 5: ...tely and will result in a link reset on both the Line and the Ethernet port s Bank 1 Dip Switches Auto Local CO Remote CPE Switch Position Mode On Default Auto Local Off Remote NOTE Ethernet Extenders...

Страница 6: ...eed Down Long Range High Speed In this mode the VDSL connection will be optimized for speed and the effective bidirectional data rate will be up to 100 Mbps in each direction This setting also enables...

Страница 7: ...Loopback Switch 5 Switch Position Mode Up default Off Down On Line Loopback Mode off This is default position for normal operation Line Loopback Mode on This is a test mode All data received on the L...

Страница 8: ...ings Ethernet Speed Switch 7 affects Port 1 only Switch Position Mode Up default 100 Mb Down 10 Mb NOTE This switch is only used if Auto negotiation has been turned off Switch 6 Ethernet Duplex Switch...

Страница 9: ...k Pass Through will need to be enabled on both the Local and Remote Ethernet Extender Link Pass Through If the Ethernet link is broken its state is reflected on the peer s Ethernet link Interlink Faul...

Страница 10: ...wn the default Normal should be used as per IEEE802 3af at standards Switch Position 3 Switch Position 4 Type Up default Up default Normal Up Down High capacitance Down Up Legacy device Down Down Norm...

Страница 11: ...mote Powering Using VDSL Line Power There are 3 strapping options to select the method of providing power over the VDSL as listed below on Jumpers J7 and J8 2 Wire This is the default setting and prov...

Страница 12: ...he rare case that the settings need to be modified All Ethernet ports on the E and PE models will connect to a PD using Alternate A These other connection options are available on Port 1 Jumper Settin...

Страница 13: ...Terminal Block connector Strip insulator sheathing from both wires 5mm 3 16th inch to expose copper conductor wire Loosen the terminal block screws and connect one wire to the left terminal Connect th...

Страница 14: ...strain relief clip For extra power cable strain relief attach the strain clip to the case and thread the power cable through the clip in either one or two loops Attaching the Grounding Lug If additio...

Страница 15: ...e Ethernet On solid Yellow PSE not active Possible causes PD not compliant PD reset in progress Off No PD connected LOC CO On Local CO mode Off RMT CPE mode Note In Auto Local mode the Ethernet Extend...

Страница 16: ...e and the attached devices for faults Repeat for the far end Ethernet Extender Check VDSL Connection Set one Ethernet Extender to Local mode and the other to Remote mode If VDSL link is not establishe...

Страница 17: ...5A n a VDSL Output 57VDC Max 0 65A n a From VDSL Line n a 23 57VDC Max 0 65A Current Draw 2 3A Max 1 1A 48VDC 2 7A Max 2 2A 56VDC 2 5A 48VDC Operating Temperature Commercial model 0 C to 50 C 32 F to...

Страница 18: ...48 m 10 000 ft Ethernet Copper Cabling Requirements Category 5e 6 7 UTP or STP 24 22 AWG Straight through or Ethernet crossover VDSL Interfaces RJ 45 Connector BNC Connector Pin Signal Terminal Block...

Страница 19: ...dapter it must be a Class ll double insulated power supply adapter If this unit is to be installed in a location where the ambient temperature exceeds 50C the case temperature may exceed safe levels F...

Страница 20: ...t_services warranty shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical Support Query may be made via this...