P/N 5500315-11 (Rev A)
Perle Gigabit
Fiber to Fiber
Media Converter
Module
Installation Guide
C-1000MM-XXXXXX Unmanaged Module
CM-1000MM-XXXXXX Managed Module
Страница 1: ...P N 5500315 11 Rev A Perle Gigabit Fiber to Fiber Media Converter Module Installation Guide C 1000MM XXXXXX Unmanaged Module CM 1000MM XXXXXX Managed Module...
Страница 2: ...SM Multimode to Single Mode Single Strand MM The first fiber port will be multimode MM and the second fiber port can be either single mode SM or multimode MM depending on the model selected They can o...
Страница 3: ...0 km 12 4 mi 1310 1490 nm C 1000MM S1SC20D CM 1000MM S1SC20D SC SM 20 km 12 4 mi 1490 1310 nm C 1000MM S1SC40U CM 1000MM S1SC40U SC SM 40 km 25 mi 1310 1490 nm C 1000MM S1SC40D CM 1000MM S1SC40D SC SM...
Страница 4: ...3 Insert the Media Converter Module into the chassis 4 Connect the fiber cables Auto Config Jumper CM 1000MM only The Auto Config jumper is J5 Refer to the diagram below for labelling Auto Pin 2 and P...
Страница 5: ...nverter will negotiate fiber parameters on both MM1 and MM2 SM2 fiber ports This will ensure the most optimal connection parameters will be in effect If connecting to another Perle media converter thi...
Страница 6: ...Up default Enabled Down Disabled Enabled If the media converter module detects a loss of fiber signal on the fiber receiver the media module will immediately disable its fiber transmitter signal on t...
Страница 7: ...verter B Configuration Link Mode Smart Link Pass Through Mode Fiber Fault Alert Sequence of Events 1 Media Converter A loses fiber connection RX on MM2 SM2 2 Media Converter A disables the transmitter...
Страница 8: ...ive RX fiber connection is looped back to the transmit TX fiber connection Note Only one fiber interface can be in loopback at a time Remote Loopback Fiber 2 Switch 5 Switch Position Mode Up default D...
Страница 9: ...slot opening 3 Set the jumpers and DIP switches on the Media Converter Module to the desired operating mode optional 4 Locate the top and bottom alignment guides inside the MCR Chassis 5 Using the mo...
Страница 10: ...te and secure the screw Installing the Duplex Fiber Cable 1 Locate a 1000Base X compliant duplex 2 strands fiber cable with appropriate connectors 2 Connect the fiber cables from one Converter to the...
Страница 11: ...n loopback mode Blinking quickly the module has a hardware error LK1 MM1 Fiber Link10 Activity On Fiber link present Blinking quickly Fiber link present and receiving data Blinking slowly The fiber li...
Страница 12: ...he UP position these methods are recommended for troubleshooting Method 1 1 Turn off Fiber Negotiation SW1 Down on both media converters Leave all other switches UP 2 Connect the near end device to po...
Страница 13: ...X Power dB RX Power dB Budget dB C 1000MM M2SC05 CM 1000MM M2SC05 MM TX 850 RX 850 Min 9 5 Max 4 Min 17 Max 3 7 5 Model Mode Wave length nm TX Power dB RX Power dB Budget dB C 1000MM M2xx05 CM 1000MM...
Страница 14: ...x 3 Min 20 Max 3 11 C 1000MM S1SC20U CM 1000MM S1SC20U SM TX 1310 RX 1490 Min 8 Max 3 Min 22 Max 3 14 C 1000MM S1SC20D CM 1000MM S1SC20D SM TX 1490 RX 1310 Min 8 Max 3 Min 22 Max 3 14 C 1000MM S1SC40U...
Страница 15: ...in which case the user will be required to correct the interference at his her own expense EN 55022 Class A WARNING This is a Class A product In a domestic environment this product may cause radio in...
Страница 16: ...e found at http www perle com support_services warranty shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical...