1
14
User’s Handbook, TSL 4230, Issue 4
4016-E61TRS
Performance data
Note: All data based on operation to ISO 3046/1, BS 5514 DIN 6271 standard reference conditions.
Test conditions
l
Air temperature - 25 °C
l
Barometric pressure - 100 kPa
l
Relative humidity - 30%
General installation
Energy balance
Note: Not to be used for CHP design purposes. (Indicative figures only). Consult Perkins Engines Company
Limited. Assumes complete combustion.
Designation
Units
Continuous baseload rating
50 Hz; 1500 rev/min
1
/
2
TA-Luft (NO
x
)
TA-Luft (NO
x
)
Gross engine power
KW
1042
1042
BMEP gross
Bar
13,6
13,6
Combustion air flow
m
3
/min
82,7
79,8
Exhaust gas temperature max (after turbo)
°C
498
497
Exhaust gas flow (max)
m
3
/min
220
212
Overall electrical efficiency
%
38.2
39.2
Mean piston speed
m/s
9,5
9,5
Charge coolant flow
l/s
10
10
Nominal excess air factor (Lambda)
λ
1,80
1,75
Typical Gen Set 25 °C (100 kPa) electrical output
(unit 1.0pf)
kW
1008
1008
Assumed alternator efficiency
%
96.7
96.7
Continuous baseload rating
Units
1500 rev/min
1
/
2
TA-Luft (NO
x
)
%
1500 rev/min
TA-Luft (NO
x
)
%
Energy in fuel (fuel heat of combustion)
kW
2638
100
2574
100
Energy in power output (net) (engine shaft power)
kW
1042
39.5
1042
40.5
Energy to exhaust cooled to 120 °C
(TA Luft)
kW
688
26.1
673
26.1
Energy to coolant (jacket, oil and 1st circuit of c/c)
kW
544
21.0
548
21.3
Sum of useable heat
kW
1340
50.8
1314
51.0
Sum of useable energy
kW
2382
90.3
2356
91.5
Energy to radiation
(surface radiation and other losses)
kW
79
3.0
49
1.9
Energy to charge cooler 2nd circuit
kW
98
3.7
93
3.0
Waste energy from exhaust gas
kW
177
6.7
171
6.6
This document has been printed from SPI². Not for Resale