14.Power-up, Configuration
Storage & NVRAM
In This Chapter
Power-up
NVRAM
Initialization Control
Settable Parameters
Signal Processing
14.1 Power-up
After receiving stable power at the Vcc pins Juno begins its initialization sequence. In a power-up where no user-
provided configuration settings have been stored this takes approximately 250 mSec. At the end of this sequence all
parameters are at their default values, and both the current loop module and the motor output module are disabled. At
this point Juno is ready to receive serial host commands by microprocessor command.
Juno also supports the ability to store configuration settings that are applied during the power up sequence. For this
purpose, Juno supports a 1,024 word memory that is non-volatile (NVRAM), meaning the data stored will be available
even after power to the Juno IC is removed.
The power-up initialization information stored in the NVRAM takes the form of host command packets, however rather
than being sent via the serial port, these packet words are stored in memory. If the non-volatile memory has been loaded
with configuration information the power-up sequence detects this and begins executing these commands. Note that
processing stored commands may increase the overall initialization time depending on the command sequence stored.
14.2 NVRAM
Juno step motor control ICs provide a 1,024 16-bit word NVRAM. The primary purpose of the NVRAM is to allow
configuration information to be stored, so that upon power up the Juno IC can be configured and initialized
automatically rather than requiring serial host commands to perform this function.
All data stored in the Juno’s NVRAM utilizes a data format known as PMD Structured data Storage Format (PSF). Users
who rely only on PMD Corp.’s Pro-Motion software package need not concern themselves with the details of PSF. Users
who want to address the NVRAM from their own software, or who want to create their own user-defined storage should
refer to the
Juno Velocity & Torque Control IC Programming Reference
for detailed information on PSF.
14.3 Initialization Control
To make the initialization sequence as flexible as possible Juno provides a facility to control execution of the initialization
commands stored in NVRAM. Command execution can be suspended for a specific period of time, or until various
internal or external conditions are satisfied. This is useful for coordinating Juno IC startup with external processes on
the user’s controller board, or to execute simple motion sequences prior to normal operation.
Содержание Juno MC71112
Страница 12: ...The Juno IC Family 12 Juno Step Motor Control IC User Guide 1 This page intentionally left blank ...
Страница 18: ...Functional Characteristics 18 Juno Step Motor Control IC User Guide 2 This page intentionally left blank ...
Страница 22: ...Electrical Characteristics 22 Juno Step Motor Control IC User Guide 3 This page intentionally left blank ...
Страница 26: ...Timing Diagrams 26 Juno Step Motor Control IC User Guide 4 This page intentionally left blank ...
Страница 46: ...Operational Overview 46 Juno Step Motor Control IC User Guide 7 This page intentionally left blank ...
Страница 54: ...Microstep Waveform Generation 54 Juno Step Motor Control IC User Guide 8 This page intentionally left blank ...
Страница 70: ...Internal Profile Generation 70 Juno Step Motor Control IC User Guide 11 This page intentionally left blank ...
Страница 78: ...Motion Monitoring Control 78 Juno Step Motor Control IC User Guide 12 This page intentionally left blank ...
Страница 86: ...Drive DC Bus Safety 86 Juno Step Motor Control IC User Guide 13 This page intentionally left blank ...
Страница 100: ...Application Notes MC74113 MC75113 100 Juno Step Motor Control IC User Guide 15 Figure 15 3 Drive Safety and Monitoring ...
Страница 103: ...Application Notes MC74113 MC75113 Juno Step Motor Control IC User Guide 103 15 Figure 15 4 Leg Current Sensing ...
Страница 114: ...Application Notes MC74113 MC75113 114 MC58113 Electrical Specifications 15 This page intentionally left blank ...