Applications: Microprocessor controlled step motor drive, programming of Juno IC NVRAM, Juno IC application development.
In this configuration a microprocessor or PC communicates via Juno’s serial host command port to control the motor
acceleration, deceleration, and maximum velocity.
Another use of this configuration is during set up to store the production configuration of the Juno IC into its
NVRAM. For more information on NVRAM setup refer to
Section 6.1, “Loading the NVRAM”
Finally the serial interface may be used in conjunction with PMD Corp.’s Pro-Motion software application to monitor
the Juno IC status during application tuning and optimization.
7.5
Host Commands
Juno ICs have more than 40 user programmable control parameters for tailoring its step motor control to a specific
application. Upon power-up these programmable settings are at their default values and are not yet tailored to a
specific application.
Juno’s serial port may be used to program these control parameters using what are known as host commands. Host
commands are data packets that follow a particular format and protocol. Alternatively the NVRAM may be used to
auto-load the control parameters upon power-up. In this case the format of the stored NVRAM data closely resembles
the serial host command packets.
Most host commands specify a single parameter but some specify two or even three. Parameters may be signed or
unsigned integers, may be bit encoded, or may specify one of a list of available values. Throughout this manual we
will show the NVRAM script file mnemonics associated with Juno host commands in table form at the end of each
chapter.
Below is an example of such a command mnemonic table showing the variable name, associated mnemonic code, and
range of settable values:
Parameter
Host Command
Mnemonic
Range & Description
PWM frequency
SetDrivePWM
Two parameter command, the first must be 3 and the
second is a fixed code value and sets the PWM frequency
to 20 kHz, 40 kHz, 80 kHz, or 120 kHz
H-Bridge
+HV
Current Feedback
MC74113, MC74113N,
MC75113, MC75113N
H-Bridge
Step
Motor
Encoder Feedback (MC74113
& MC74113N only)
PC or
Microprocessor
via Serial Host
Commands
Enable
Содержание Juno MC71112
Страница 12: ...The Juno IC Family 12 Juno Step Motor Control IC User Guide 1 This page intentionally left blank ...
Страница 18: ...Functional Characteristics 18 Juno Step Motor Control IC User Guide 2 This page intentionally left blank ...
Страница 22: ...Electrical Characteristics 22 Juno Step Motor Control IC User Guide 3 This page intentionally left blank ...
Страница 26: ...Timing Diagrams 26 Juno Step Motor Control IC User Guide 4 This page intentionally left blank ...
Страница 46: ...Operational Overview 46 Juno Step Motor Control IC User Guide 7 This page intentionally left blank ...
Страница 54: ...Microstep Waveform Generation 54 Juno Step Motor Control IC User Guide 8 This page intentionally left blank ...
Страница 70: ...Internal Profile Generation 70 Juno Step Motor Control IC User Guide 11 This page intentionally left blank ...
Страница 78: ...Motion Monitoring Control 78 Juno Step Motor Control IC User Guide 12 This page intentionally left blank ...
Страница 86: ...Drive DC Bus Safety 86 Juno Step Motor Control IC User Guide 13 This page intentionally left blank ...
Страница 100: ...Application Notes MC74113 MC75113 100 Juno Step Motor Control IC User Guide 15 Figure 15 3 Drive Safety and Monitoring ...
Страница 103: ...Application Notes MC74113 MC75113 Juno Step Motor Control IC User Guide 103 15 Figure 15 4 Leg Current Sensing ...
Страница 114: ...Application Notes MC74113 MC75113 114 MC58113 Electrical Specifications 15 This page intentionally left blank ...