background image

Version 1.0

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

INS8370A

 

Intel

® 

Comet Lake-S 10th Processor with 

Q470E/H420E Chipset Mini-ITX 

 

 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

www.perfectron.com

 

Содержание INS8370A

Страница 1: ...Version 1 0 INS8370A Intel Comet Lake S 10th Processor with Q470E H420E Chipset Mini ITX www perfectron com ...

Страница 2: ...g contact your local power company If the power supply is broken do not try to fix it by yourself Contact a qualified service technician or your localdistributor Operation safety Beforeinstallingthemotherboardandaddingdevicesonit carefullyreadallthemanualsthat came with thepackage Beforeusingtheproduct makesureallcablesarecorrectlyconnectedandthepowercablesare not damaged Ifyoudetectanydamage cont...

Страница 3: ...tner and to protect our environment In order to meet the RoHS compliant directives Perfectron has established an engineering and manufacturing task force to implement the introduction of green products The task force will ensure that we follow the standard Perfectron development procedure and that all the new RoHS components and new manufacturing processes maintain the highest industry quality lev...

Страница 4: ...evision Date yyyy mm dd Changes V1 0 2022 03 10 First release Packing List Item Description Q ty 1 INS8370A 1 2 CD Drivier User s manual 1 3 Power Cable 1 If any of the above items is damaged or missing please contact your local distributor ...

Страница 5: ... Settings 11 Chapter 3 AMI BIOS UTILITY 16 3 1 Staring 17 3 2 Navigation Keys 17 3 3 Main Page 18 3 4 Advance Page 20 3 4 1 Onboard Device 22 3 4 2 CPU Configuration 24 3 4 3 Trusted Computing 26 3 4 4 Super IO Configuration 27 3 4 5 Serial Port 1 Configuration 28 3 4 6 Serial Port 2 Configuration 29 3 4 7 Hardware Monitor 30 3 4 8 RTC Wake Settings 31 3 4 9 Netword Stack Configuration 32 3 4 10 N...

Страница 6: ...Security Page 38 3 6 1 HDD Security 39 3 6 2 Secure Boot 40 3 6 3 Key Management Secure Boot Mode set to Custom 41 3 6 4 BIOS Update 44 3 7 Boot Page 45 3 7 1 List Boot Device Type Drive BBS Priorities 48 3 8 Save Exit Page 49 ...

Страница 7: ...re Monitor Voltage Monitor Fan Monitor Watchdog Timer 1 255 steps by software program Smart Fan Control CPU Fan System Fan Expansion M 2 1 x M 2 2230 E key PCIe USB M 2 2242 2280 M key PCIeX4 SATA Mini PCie 1 x Mini PCIe Full size PCIe USB SATA PCIe Slot 1 x PCIe 3 0 X16 slot Display HDMI Up to 4K 4096 x 2160 30 Hz Displayport Up to 4K 4096 x 2304 60 Hz LVDS Up to 1920 x 1200 60 Hz eDP Option Up t...

Страница 8: ...or 1 x AT ATX Mode Select Jumper ATX 12V Power Connector 24 pin 4 pin Others 1 x CMOS Jumper 1 x Front Audio Header Mic in Line out 1 x panel power select header 1x buzzer header 1 x SPDIF Mechanical and environmental Form Factor Mini ITX Power Type ATX 24 pin 4 pin 12V DC 3pin terminal connector via cable by connecting to AT Dimension 170 mm x 170mm Operating Temp ET 20 70 C UT 40 85 C Storage Te...

Страница 9: ...www perfectron com 8 1 2 Block Diagram ...

Страница 10: ...www perfectron com 9 1 3 Board Placement ...

Страница 11: ...DIMM Socket 5 LVDS eDP Connector 6 LVDS Backlight Header 7 Panel Power Option 8 CPU Fan Header 9 System Fan Header 10 Front Pane Header 11 SATA Port 12 Full Size Mini PCIe Slot 13 ATX 24Pin 14 USB3 0 Connector 15 M 2 2230 E Key 16 USB2 0 Header 17 SPDIF Header 18 CPU Socket 19 RTC Battery header 20 Buzzer Header 21 MiAPI Header 22 Clear CMOS Header 23 AT ATX Mode Jumper ...

Страница 12: ... 16 NC must NOT be used in single 12V mode 2 Pin9 10 11 are responsible for the operating mode 3 Pin9 Leave open or connect to 12V Don t connect to GND All four 12Vin pins must be connected to the 12V supply source Both GND pins 4 pin conn two GND pins 24 pin connector must be connected to the supply source Important Note Single 12V mode The output pins 3 3Vout 5Vout 12Vout provide power for drive...

Страница 13: ...e mainboard is in Single 12V operating mode Single 12V Operation Cabling Notes Please use MiTAC suggest cable 3pin terminal connector to 24p ATX 4pin ATX SATA power convert cable 422D83800004 for single 12V operation Cable drawing as below P1 3pin terminal connector Pin1 12v Pin2 NC Pin3 GND for 12V input P2 4pin 12V connector for CPU power P3 24pin ATX connector P4 SATA Power P5 SATA Power ...

Страница 14: ...0_CON_DN 25 GND 26 GND 27 LVDS1_LINK3_CON_DP 28 LVDS1_LINK2_CON_DP 29 LVDS1_LINK3_CON_DN 30 LVDS1_LINK2_CON_DN 31 GND 32 GND 33 LVDS1_CLK_CON_DP 34 LVDS0_CLK_CON_DP 35 LVDS1_CLK_CON_DN 36 LVDS0_CLK_CON_DN 37 GND 38 GND 39 12V 40 12V eDP Connector Optional PIN DEFINITION PIN DEFINITION 1 VCC3 2 Panel Power 3 VCC3 4 Panel Power 5 EDP_CPU_AUXN 6 EDP_CPU_AUXP 7 GND CABLE_ID1 8 HPD 9 eDP1_DP 10 eDP0_DP...

Страница 15: ... 7 BRIGHT_UP 8 BRIGHT_DOWN Panel Power Option CPU FAN Header PIN DEFINITION 1 GND 2 12V 3 CPU_FAN_TACH 4 CPU_FAN_CTRL System FAN Header PIN DEFINITION 1 GND 2 12V 3 System_FAN_TACH 4 System _FAN_CTRL Front Panel Header PIN DEFINITION PIN DEFINITION 1 Key no pin 2 VCC3 3 12V 4 LCD_VCC_SEL 5 Key no pin 6 VCC 3 3V 5V Default 12V ...

Страница 16: ...e 6 Data positive 7 GND 8 GND 9 Key no pin 10 No Connect SPDIF Header PIN DEFINITION 1 GND 2 SPDIF OUT 3 N A 4 Power 5V MiAPI Header PIN DEFINITION PIN DEFINITION 1 MAPI_GPIO1 2 VCC 3 MAPI_GPIO2 4 MAPI_GPIO6 5 MAPI_GPIO3 6 MAPI_GPIO7 7 MAPI_GPIO4 8 MAPI_GPIO8 9 MAPI_GPIO5 10 MAPI_GPIO9 11 WD_Time 12 MAPI_GPIO10 13 Power Button 14 SMBUS_DATA 15 UART_TX 16 SMBUS_CLK 17 UART_RX 18 5VSB 19 GND 20 N A ...

Страница 17: ...ial Port Pin Out PIN RS232 RS422 RS485 1 DCD TX DATA 2 RXD TX DATA 3 TXD RX NC 4 DTR RX NC 5 GND GND GND 6 DSR NC NC 7 RTS NC NC 8 CTS NC NC 9 RI NC NC Chapter 3 AMI BIOS UTILITY PIN DEFINITION 1 2 AT Mode 2 3 ATX Mode Default ...

Страница 18: ...of the BIOS setup utility hot keys can be used at any time during the setup navigation process Some of the hot keys are F1 F10 Enter ESC and Arrow keys Left Right The Left and Right Arrow keys moves the cursor to select a menu Up Down The Up and Down Arrow keys moves the cursor to select a setup screen or sub screen Plus Minus The Plus and Minus Arrow keys changes the field value of a particular s...

Страница 19: ...o help text associated with it Field Name Compliancy Default Value UEFI 2 7 PI 1 6 Comment This field is not selectable There is no help text associated with it Field Name BIOS Version Default Value Display the version of the BIOS Comment This field is not selectable There is no help text associated with it Field Name Build Date and Time Default Value Display build date of the BIOS Comment This fi...

Страница 20: ...2 Default Value Display the installed memory size of slot2 Comment This field is not selectable There is no help text associated with it Field Name Memory Frequency Default Value Display the installed memory Frequency Comment This field is not selectable There is no help text associated with it Field Name Serial ATA Port 1 Default Value Display the installed SATA device model size of port 1 Commen...

Страница 21: ...n Date elements Default Rangers Year 1998 2099 Months 1 12 Days Dependent on month Range of Years may vary Field Name System Time Default Value hh mm ss Possible Value hh 0 23 mm 0 59 ss 0 59 Help Set the Time Use Tab to switch between Time elements 3 4 Advance Page Field Name Onboard Device Help Onboard Device Configuration Comment Press Enter when selected to go into the associated Sub Menu ...

Страница 22: ...r when selected to go into the associated Sub Menu Field Name S5 RTC Wake Settings Help Enable system to wake from S5 using RTC alarm Comment Press Enter when selected to go into the associated Sub Menu Field Name Network Stack Configuration Help Network Stack Settings Comment Press Enter when selected to go into the associated Sub Menu Field Name NVMe Configuration Help NVMe Device Options Settin...

Страница 23: ...o be available and enabled Field Name State After G3 Default Value S5 State Possible Value S0 State Help Specify what state to go to when power is re applied after a power failure Field Name Force Enable LVDS Default Value Disabled Possible Value Enabled Help Force Enable LVDS Enabled Enable LVDS whether plug correct panel Field Name DVMT Pre Allocated Default Value 64M Possible Value 64M 32M F7 3...

Страница 24: ...on set to Intel RST PremiumWith Intel Optane System Acceleration Default Value Not RST Controlled Possible Value Not RST Controlled RST Controlled Help Enable Disable RST Pcie Storage Remapping Field Name Wake on LAN Enable Default Value Enabled Possible Value Enabled Disabled Help Enable Disable integrated LAN to wake the system Field Name HD Audio Default Value Enabled Possible Value Enabled Dis...

Страница 25: ...ld is not selectable There is no help text associated with it Field Name ID Default Value Displays CPU Signature Comment This field is not selectable There is no help text associated with it Field Name Speed Default Value Displays the CPU Speed Comment This field is not selectable There is no help text associated with it Field Name L1 Data Cache Default Value L1 Data Cache Size Comment This field ...

Страница 26: ...d Name L3 Cache Default Value L3 Cache Size Comment This field is not selectable There is no help text associated with it Field Name L4 Cache Default Value L4 Cache Size Comment This field is not selectable There is no help text associated with it Field Name VXM Default Value L3 Cache Size Comment This field is not selectable There is no help text associated with it Field Name SMX TXT Default Valu...

Страница 27: ...no help text associated with it Field Name Security Device Support Default Value Enable Possible Value Enable Disable Help Enables or Disables BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available Field Name Pending operation Default Value None Possible Value None TPM Clear Help Schedule an Operation for the Security Device NO...

Страница 28: ...1 Configuration Help Set Parameters of Serial Port 1 COMA Comment Press Enter when selected to go into the associated Sub Menu Field Name Serial Port 2 Configuration Help Set Parameters of Serial Port 2 COMB Comment Press Enter when selected to go into the associated Sub Menu ...

Страница 29: ...ngs Default Value Device Super IO COM1 Address and IRQ Comment This field is not selectable There is no help text associated with it Field Name Change Settings Default Value AUTO Possible Value Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Help Select an optimal settings for Super IO Device ...

Страница 30: ...ngs Default Value Device Super IO COM2 Address and IRQ Comment This field is not selectable There is no help text associated with it Field Name Change Settings Default Value AUTO Possible Value Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Help Select an optimal settings for Super IO Device ...

Страница 31: ... ENABLE Low Active Disabled Help Select an optimal settings for Super IO Device 3 4 7 Hardware Monitor Type Range CPU Temperature 20 By Processor Tjmax C CPU VR Temperature 20 120 C DIMM Temperature 20 120 C CPU Fan Speed There are many kinds of the fan could be installed into the syste so we could only set 0 RPM for the failed fan speed and there is also no high RPM limitation Front Fan Speed CPU...

Страница 32: ...an Enable Suppressed if Hardware Monitor Alert is Disabled Default Value Disabled Possible Value Enabled Disabled Help If Enabled POST monitors voltage temperature and fan status If these values are out of range BIOS display warning message and tur on beep sound 3 4 8 RTC Wake Settings Field Name Wake system from S5 Default Value Disabled Possible Value Disabled Fixed Time Help Enable or disable S...

Страница 33: ...up hour Show when Wake system from S5 set to Fixed Time Default Value 0 Possible Value 0 59 Help Select 0 59 For Minute Field Name Wake up hour Show when Wake system from S5 set to Fixed Time Default Value 0 Possible Value 0 59 Help Select 0 59 For Second 3 4 9 Network Stack Configuration Field Name Network stack Default Value Disabled Possible Value Disabled Enabled Help Enable Disable UEFI Netwo...

Страница 34: ...d Help Enable Disable Ipv4 PXE Boot Support If disabled IPV4 PXE boot support will not be available Field Name Ipv6 PXE Support Available when Network stack Enabled Default Value Enabled Possible Value Disabled Enabled Help Enable Disable Ipv6 PXE Boot Support If disabled IPV6 PXE boot support will not be available 3 4 10NVMe Configuration ...

Страница 35: ...nology Field Name Create RAID Volume Help This page allows you to create a RAID volume Field Name Raid Volume Help Select to see more information about the RAID Volume Field Name Non RAID Physical Disks Help Select to see more information about the disk ...

Страница 36: ...ngs Help Press to change the Smbios Event Log configuration Comment Press Enter when selected to go into the associated Sub Menu Field Name View Smbios Event Log Help Press to view the Smbios Event Log records Comment Press Enter when selected to go into the associated Sub Menu ...

Страница 37: ...of Smbios Event Logging during boot Field Name Erase Event Log Default Value No Possible Value No Yes Next reset Yes Every reset Help Choose options for erasing Smbios Event Log Erasing is done prior to any logging activation during reset Field Name When Log is Full Default Value Do Nothing Possible Value Do Nothing Erase Immediately Help Choose options for reactions to a full Smbios Event Log ...

Страница 38: ...www perfectron com 37 3 5 2 View Smbios Event Log Field Name DATE TIME ERROR CODE SEVERITY COUNT Default Value MM DD YY HH MM SS Smbios 0x16 N A N A Possible Value By Events Help By Events ...

Страница 39: ...cure Boot Help Set User Password Comment Press Enter when selected to go into the associated Sub Menu Field Name BIOS Update Help BIOS Update support Comment Press Enter when selected to go into the associated Sub Menu Field Name HDD Security drive Help HDD Security Configuration for selected drive Comment Press Enter when selected to go into the associated Sub Menu ...

Страница 40: ...et HDD User Password Advisable to Power Cycle System after Setting Hard Disk Passwords Discard or Save changes option in setup does not have any impact on HDD when password is set or removed If the Set HDD User Password option is hidden do power cycle to enable the option again ...

Страница 41: ... platform reset Field Name Secure Boot Mode Default Value Standard Possible Value Standard Custom Help Secure Boot mode options Standard or Custom In Custom mode Secure Boot Policy variables can be configured by a physically present user without full authentication Field Name Restore Factory Keys Help Force System to User Mode Install factory default Secure Boot key databases Field Name Reset to S...

Страница 42: ...fault Value Disabled Possible Value Enabled Disabled Help Install factory default Secure Boot keys after the platform reset and while the System is in Setup mode Field Name Restore Factory Keys Help Force System to User Mode Install factory default Secure Boot key databases Field Name Reset to Setup Mode Help Delete all Secure Boot key databases from NVRAM Field Name Export Secure Boot variables H...

Страница 43: ...FI PE COFF Image SHA256 Key Source Factory External Mixed Comment Press Enter when selected to go into the associated Sub Menu Key Management Field Name Key Exchange Keys Default Value Size 0 Keys 0 Key source No Keys Help Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER c EFI_CERT_RSA2048 bin d EFI_CERT_SHAXXX 2 Authenticat...

Страница 44: ...Value Size 0 Keys 0 Key source No Keys Help Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER c EFI_CERT_RSA2048 bin d EFI_CERT_SHAXXX 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Factory External Mixed Comment Press Enter when selected to go into the associated Sub Menu Field Name OsRecovery Signatures...

Страница 45: ...www perfectron com 44 3 6 4 BIOS Update Field Name Path for ROM Image Help Enter the path to the Secure flash option ...

Страница 46: ...lt Value Off Possible Value On Off Comment Select the keyboard NumLock state Field Name Boot Option 1 Default Value USB Floppy Possible Value USB Floppy CD DVD USB CD DVD Hard Disk USB Key USB Hard Disk NVME Network Disabled Comment Sets the system boot order Field Name Boot Option 2 Default Value USB CD DVD Possible Value USB Floppy CD DVD USB CD DVD Hard Disk USB Key USB Hard Disk NVME Network D...

Страница 47: ...D Hard Disk USB Key USB Hard Disk NVME Network Disabled Comment Sets the system boot order Field Name Boot Option 7 Default Value Network Possible Value USB Floppy CD DVD USB CD DVD Hard Disk USB Key USB Hard Disk NVME Network Disabled Comment Sets the system boot order Field Name Boot Option 8 Default Value Network Possible Value USB Floppy CD DVD USB CD DVD Hard Disk USB Key USB Hard Disk NVME N...

Страница 48: ...ated Sub Menu Field Name UEFI USB Hard Disk Drive BBS Priorities Help Specifies the Boot Device Priority sequence from available Hard Disk Drives Comment Press Enter when selected to go into the associated Sub Menu Field Name UEFI NVME Drive BBS Priorities Help Specifies the Boot Device Priority sequence from available Hard Disk Drives Comment Press Enter when selected to go into the associated Su...

Страница 49: ...www perfectron com 48 3 7 1 List Boot Device Type Drive BBS Priorities Field Name Boot Option 1 Default Value Possible Value Boot Device Name 1 of this type Disable Help Sets the system boot order ...

Страница 50: ...Name Save Changes and Reset Help Reset the system after saving the changes Field Name Discard Changes and Rest Help Reset system setup without saving any changes Field Name Restore Defaults Help Restore Load Default values for all the setup options ...

Отзывы: