7.
Cleaning and Maintenance
All screws should be tight and free of corrosion.
The housing, the visible parts, the mounting supports and the
installation location (e.g. ceiling, suspension, trussing) should not be
deformed, modified or tampered with; e.g. do not drill extra holes in
mounting supports, do not change the location of the connections…
Mechanically moving parts must not show any signs of wear and tear.
The electric power supply cables must not show any damage. Have a
qualified technician maintain the device.
If the protective glass is damaged, disconnect the lamp immediately
from the mains. Have it repaired immediately by a qualified technician.
Do not use the lamp with a cracked or broken protective glass.
This luminaire does not have a built-in device to disconnect it from the
electric mains. Make sure to electrically isolate the luminaire before
installation or maintenance activities are performed.
Wipe the device regularly with a moist, lint-free cloth. Do not use
alcohol or solvents.
There are no user-serviceable parts.
Contact your dealer for spare parts if necessary.
8.
Technical Specifications
LEDA4011RGB
LEDA4012RGB
body colour
white
electrical data
power LED module
6x 3 W RGB SMD LED
14x 3 W RGB SMD LED
total nominal power
10 W
20 W
nominal voltage
driver
230 V~
nominal voltage
LED module
red
2.0-2.2 V
green
3.0-3.2 V
blue
3.0-3.2 V
power factor
0.5
energy
consumption
10 kWh/1000 h
20 kWh/1000 h
cable
H05RN-F 3G1.0 - 30 cm
light technical data
colour
RGB
colour temperature
N/A
beam angle
110°
luminous intensity
60 cd
145 cd