Percy Doughty & Co FIREFOX 8 Скачать руководство пользователя страница 1

  

FIREFOX 

CAST IRON MULTI-FUEL STOVE  

V 5.2 

Conforms to EN13240:2001  

Constructional Requirements 

For Intermittent Use 

Not to be used in a shared flue 

FIREFOX 8 CLEAN BURN 

INSTALLATION AND OPERATING INSTRUCTIONS 

(to be left with the householder) 

This stove operates at very high temperatures. All persons including children and the 
infirm should be warned of this and not be allowed to touch any surfaces whilst in use. 
The operator must use the tools provided. The mitten provided is a tool. 

APPROVED 

REV: E  Jul/2015 

Содержание FIREFOX 8

Страница 1: ...X 8 CLEAN BURN INSTALLATION AND OPERATING INSTRUCTIONS to be left with the householder This stove operates at very high temperatures All persons including children and the infirm should be warned of t...

Страница 2: ...Diam Ventilation Reqt Ventilation Reqt with draught stabilizer 407O C 5 5 g s wood 9 4 g s ancit 150mm 6 inches 2145mm2 3 32in2 4815mm2 7 46in2 As tested to the requirements of EN13240 for intermitte...

Страница 3: ...Blanking Plate 3 5 6 FFX8001 Stove Body Rear Right Left Panel 4 FFX8003 Stove Top Panel 7 FFX8002 Stove Base Panel 10 FFX8007 Stove Baffle Plate 11 FFX8012 Side Brick 12 FFX8013 Back Brick 13 FFX8010...

Страница 4: ...LIED WITH THIS APPLIANCE HAS BEEN EXTENSIVELY TESTED FOR SAFETY AND EFFICIENCY DO NOT ATTEMPT TO MODIFY IT ALWAYS USE GENUINE REPLACEMENT PARTS AS RECOMMENDED BY YOUR SUPPLIER FAILURE TO ADHERE TO THI...

Страница 5: ...ntrolled and to prevent overfiring If you have any doubts about the suitability of your chimney consult your local dealer stockist The chimney must be swept before connection to the stove and swept ev...

Страница 6: ...rated Ensure all parts are fitted in accordance with the instructions On completion of the in stallation allow a suitable period of time for any fire cement and mortar to dry out before lighting the s...

Страница 7: ...m OPERATING INSTRUCTIONS Primary Air Primary air is controlled via the sliding vents in the bottom of the door this provides a convention al air draught to the bed of the fire indicates more air indic...

Страница 8: ...red This appliance is designed to be operated with the door closed Except for refuelling not only is it unsafe to operate with the door open but the appliance efficiency will be reduced dramatically 1...

Страница 9: ...n attached riddling rod To remove unscrew control knob and rotate grate out of its guide hole The centre grate can now 9 Solid Fuels We recommend the majority of approved manufactured smokeless fuels...

Отзывы: