WMD-06 Motorized electromechanical swing gate
Figure 5. Standard orientation of RC panel relative to gate opening direction
Table 2. Connection of RC panel cable to
XT2
connector block in standard and reversed
orientation of the RC panel
Orientation
Number
Title
Standard
Reversed
1
Fire Alarm
- -
2
GND
- -
3
GND
black black
4
Unlock A
white green
5
Stop
blue blue
6
Unlock B
green white
7
Led A
yellow red
8
Stop
orange orange
9
Led B
red yellow
10
Sound
brown brown
5.4 Input and output signals parameters
The microcontroller installed on the control board tracks the status of
Unlock A
,
Stop
,
Unlock B
and
Fire Alarm control
input signals, and also tracks output signals from rotation sensor.
Upon received data the microcontroller generates commands for the gate control mechanism and
also signals for connected external indication devices, indication on the RC panel (
Led A
,
Led Stop
and
Led B
), signals on the performed rotation of the swing panel on outputs
Pass
А
and
Pass
В
.
5.4.1 Inputs for control devices connection
The swing gate can be operated with RC panel, WRC device or ACS controller.
A device that sends
Fire Alarm
signal is used for passage emergency unlocking
.
Note:
Control devices (RC panel, WRC device, ACS controller) can be connected separately or in
any combination with each other.
In case of combined connection, the overlapping of signals sent by control devices may
occur. In such case the reaction of the gate will correspond with the reaction towards the
generated combination of input signals.
9