OPERATION INSTRUCTIONS
When operation the equipment, observe precautions (Clause 7.2).
Warning!
•
Do not move through the turnstile passage area any objects with dimensions
exceeding the width of the passageway.
•
Do not jerk and hit any elements of the turnstile so as to prevent their
mechanical deformation.
•
Do not dismantle or adjust mechanisms ensuring operation of the turnstile.
•
Do not use substances for cleaning of the turnstile that may cause mechanical
damage or corrosion of the surfaces.
9.1 Power-up
Follow these steps:
1. Check accuracy of all the connections.
2. Make sure the upper barrier arm is in emergency position (passage area is free).
3. Connect the turnstile power supply unit to the AC outlet with the voltage and
frequency rating according to the certificate for the power supply unit. Red
indicators (ban on passage) will light up on the indication modules, on the RC panel
the red indicator above “Always locked” will light up
.
4. Manually lift up the folding arm. The arm will be fixed in this position.
5. Check operation of the intrusion detector and siren (if included in the delivery set
and installed accordingly). After the power-up wait until the moment of the test
indicator (inside the intrusion detector) going off (from 10 to 50 sec). Put your hand
before the intrusion detector. The continuous signal will sound when the intrusion
detector activates. To eliminate that sound signal press any button on the RC panel.
The sound will stop without pressing the button in 5 sec.
The turnstile is ready for operation.
9.2 Operating modes of the turnstile at pulse control mode
See Table 5 for the operating modes set from the RC panel and for the corresponding
indication. Setting the operating modes for each direction is independent, i.e. setting
the operating mode for one direction does not change the operating mode set earlier
for the opposite one.
Note:
Pressing the button on the RC panel corresponds to the low-level signal supply to
the contacts (“
Unlock A
”, “
Unlock B
” and “
Stop
”) of the
XS1
connector block
relatively to the contact “
GND
”.
The RC panel overall view is given in Fig. 4. Herewith:
•
The
“Single passage in the set direction”
mode can be changed to the
“Always
free”
mode for the same direction, or to the
“Always locked”
mode.
•
The
“Free passage in the set direction”
mode can be changed to the
“Always
locked”
mode only.
•
In the
“Single passage in the set direction”
mode the turnstile will close
automatically after a person’s passage in the set direction. The turnstile will also
close automatically, if the passage is not made within 5 sec.
•
In the
“Bi-directional single passage”
mode after the passage in one direction the
countdown of the passage waiting time (5 sec.) for the opposite direction is
recommenced.