background image

WARRANTY CARD

WARRANTY REPAIR COUPON

Cutting line

Cutting line

1

.

APPLICATION

Fig. 1.  LB-85.1 electromechanical lock design

- Not included in the delivery set

*

1

2

3

4

3.  STANDARD DELIVERY SET

Fig. 3.  LB-85.1 electromechanical lock layout

LB-85.1

  is a normally-closed electromechanical mortise door lock (hereinafter 

– the lock), designed to be used as an operating device as a part of access 

control system (hereinafter – ACS) to control light and medium office doors. 

Lock features:

•  the lock has a unique construction, allowing to connect lock control cable

  through the strike plate in the door frame, not through the door leaf, which

  makes installation easier;
•  the lock can be installed in wooden and non-metallic doors 38-50 mm thick;
•  a universal lock construction enables its installation on both right-handed

   and left-handed doors;
•  the lock is designed for use with standard lock cylinders;
•  all components of the lock and strike plate have corrosion-resistant coating;
•  the lock is resistant to self-opening (for instance, as a  result of a hard kick

   on the door);
•  the lock has low power consumption (max 2 W);
•  the design of the lock does not require preventive maintenance and

   lubrication from the customer for the entire period of operation;
•  the lock closes automatically at shutting the door;
•  the lock can be released with the key or by a signal from ACS;
•  de-energized lock can be released with the key only.

The lock with regard to resistance to environmental exposure complies with 

GOST 15150-69, category NF4 (operation in premises with climate control).

Operation  of  the  lock  is  allowed  at  ambient  air  temperature  from  +1°C  to 

+40°C and at relative air humidity of 75% at +15°C.

The lock has a marking in the form of label located on its housing. The label 

contains product name, its serial number, the manufacture date and its main 

technical specifications.
The  product  is  packed  in  a  carton  box,  protecting  it  from  being  damaged 

during transportation and storage.

Box dimensions (L × W × H) ...................................................... 12×22×4 cm

Gross weight ............................................................................... max. 0.7 kg
Lock  storage  is  allowed  indoors  at  ambient  air  temperature  from  -50°С  to 

+50°С. Storage time in closed package is 12 months. 

The lock in the original package can be delivered by means of land (railway 

and  road),  sea  and  air  transport.  It  is  allowed  to  stack  the  boxes  while  in 

transit.

2. TECHNICAL SPECIFICATIONS

          

Attention!

          Due to the continual product improvement the manufacturer 

          reserves the right to  introduce amendments in product 

          design without previous notice.

Technical parameters of the lock comply with GOST 538-2001 and 

GOST 5089-2011.
DC voltage ..................................................................................... 11 – 13 V
Operational current ................................................................... 0.08 - 0.12 A
Power consumption ........................................................................ max. 2W
Type (fail-safe performance) ................................................ normally-closed
Bolt throw, not less than ..................................................................... 15 mm
Centre-to-centre spacing .................................................................... 85 mm
Dimensions .......................................................................... 85×22×187 mm
Weight .......................................................................... not more than 0.5 kg
Lock type .......................................................................................... cylinder
Unauthorized access protection (UAP) .......... normal, GOST R 51241-2008
Resistance to opening .......................................... І as per GOST 5089-2011
Safety requirements  .................................................. GOST R IEC 335-1-94
Electric shock protection class  ...................III as per GOST R IEC 335-1-94
MTBF ............................................................. 200000 number of operations
Average lifetime ................................................................................ 8 years

Design and composition of the lock are shown in Fig. 1. 

         Attention!
         Check the delivery set upon product receipt.  

Lock .............................................................................................................

 

1

Strike plate ...................................................................................................

 

1

Terminal block ..............................................................................................

 

1

2

1

2

4

5

6

7

8

9

3

11

12

13

14

10

15

1. Lever  ; 2. Key; 3. Escutcheon plate fastening screw; 4. Escutcheon plate  ; 

5. Lever rod  ; 6. Lock cylinder  ; 7. Lock; 8. Screw 3.9×25; 

9. Strike plate; 10. Terminal block; 11. Terminal clamps; 

12. Locking mechanism roller; 13. Locking bolt; 14. Forend plate; 

15. Lock cylinder fastening screw M5×50

*

*

*

*

Position

Unit

Note

1

Control cable of the ACS controller 

2

Reed switch cable

A1

Power supply unit

12V; 0,5А; 6 W

A2

Lock controller

A3

Terminal block

А4

Lock

S1

Reed switch

)

A

C

6

1

E

K

6

P

,

B

5

1

-

6

0

W

Z

B

(

V

8

1

5

1

Suppressor

1

D

V

A2

Input

NO

C

NC

+12V

VD1

Terminal 

   block

Lock

magnet

S1

A1

A3

A4

Contact 1
Contact 2

1
2

Contact 1
Contact 2

1

2

ACS controller

IN

GND

Output

+U

GND

+12V

+U

GND

    The universal construction provides use of standard pin-type lock cylinders, standard 

    EuroDIN (V DIN 18254), e.g. type 8809, 8209, 8259 produced  by company ISEO 

    (Italy), or lock cylinders of D series by Wilco Supply (type 254 – 274 – 294, 453, 454,

    554). 

The length of lock cylinder fastening screw should not exceed 50 mm

.

    The lock cylinder with a set of keys, door levers with fixing elements, reed switch, 

   control and reed switch cables are not included in the delivery set.

2

1

Fig. 2.  LB-85.1 electromechanical lock installation layout

A

A

B

B

A-A

40,5 

±1

2,5±1,5

44

2

2

R3

34

4

15

12

R10

27

87

40

21

85

16

holes 

Ø7

Ø20

holes

Ø3,5×30

145

22

16

165

R11

B-B

С

С

С-С

Ø3,5×30

holes

3

24

56

80

100

2

35°

31

L / 2 

±0,5 

L / 2 

±0,5 

L=38...50

L - Thickness of door leaf

Screw 2.9×13 DIN7982 .........................

.

....................................................... 2

Screw 3.9×25 DIN7982 ..................

4

  ..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

1

  ..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

e

t

a

l

p

m

e

n

o

it

a

ll

a

t

s

n

I

1

 

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

 l

a

u

n

a

m

 

n

o

it

a

r

e

p

o

 

d

n

a

 

e

t

a

c

if

it

r

e

C
Package box ................................................................................................. 1

1

  ..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

.

.0

5

×

5

M

 

w

e

r

c

s

 

g

n

i

n

e

t

s

a

r

e

d

n

il

y

c

 

k

c

o

L

Отзывы: