19.
Attention!
If the passage permission indication of the card capture reader is controlled
directly from the control board of the turnstile, then, it is not necessary to fulfill
the requirements of this paragraph.
In the left part of the working area, select the
"Additional outputs, activated during
the OD unblocking"
parameter and set:
set
"For the operation time"
value for the
"Activation criteria"
parameter by
using the drop-down list.
in the appeared list of additional outputs check
"Additional output
№..."
(number of the output that is physically connected to the
“LED”
input of the card
capture reader).
Now, the ACS-controller will always switch on the permission indication on the card
capture reader when you unlock the OD in this direction.
20. Click
"Save and close"
button. The
"Device properties"
window will be closed all
settings will be saved.
Appendix 2. Configuring in the Web interface CT/L-04.2,
CT-03.2 for working with the card capture reader
Attention!
You can configure the most basic algorithm of cards withdrawal by using the Web
interface. Advanced options are available in
PERCo-Web
software.
CT/L-04
(
CT-
03
) controllers don't support operation with the card capture reader via Web-
interface.
1. In
"Configuration"
"Edit"
"Operating devices"
section, select the OD that is
physically connected to the card capture reader, then select
"Reader 1"
or
"Reader 2"
depending on the direction of the passage that is controlled by the card
capture reader. Set the following parameters for the reader:
set
the
"External verification device"
value for the
"Verification"
parameter,
within the
"External device verification in ACM "Control"
group of parameters
set
"Yes"
value
for the
"Visitor pass verification"
parameter
and
also set the
required values
for
"Visitor verification activation"
and
"External device
verification waiting period"
parameters.
2. Set the following parameters in
"Configuration"
"Edit"
"Physical contacts"
section:
set the following parameter values for input that is physically connected to the “Card
captured” output of the card capture reader:
-
"Normal state:"
–
"Cut"
,
-
"Function:"
–
"External verification device confirmation input"
,
-
"Operating device:"
–
"1"
(number of OD that is physically connected to the
card capture reader),
Содержание IC-05