background image

Certificate & Operation Manual 

The  storage  of 

FP-01C 

panel

 

in  the  original  package

 

is  allowed  indoors  at  ambient  temperature 

from -

40°C to +50°C and at relative air humidity up to 80% at +15°C. In the storage room should 

also be no acid fumes and gases, causing the corrosion.  

After  transportation  and  storage  of  the  card  capture  reader  at  negative  temperatures  or  high 
humidity, it is necessary to keep it in package within the required operation conditions for minimum 
24 hours before installation.  

Due to constant improvement of the products manufacturer has a right to make any modifications 
of the equipment, which do not make its technical specifications worse without prior notice.   

2  TECHNICAL SPECIFICATIONS 

DC operating voltage  ..............................................................................................  21.6-28 V DC 
Current consumption  ....................................................................................................  min. 1.8

1

 

Power consumption ......................................................................................................  max. 56 W 
Card container capacity ................................................................................................  150 

– 300

2

  

Mean time before failure  ...................................................................  min. 1,000,000 card captures 
Mean lifetime  ............................................................................................................. min. 8 years 
Electric shock protection class  ................................................................................  III (IEC 61140) 
Ingress Protection Rating  ....................................................................................  IP41 (EN 60529) 
Overall dimensions (L × W × H)  ........................................................................  140×180×987 mm 
Weight (net)  ..................................................................................................................  max. 7 kg 

3  DELIVERY SET 

FP-01C 

panel .............................................................................................................................  1 

Key from the card container lock  ................................................................................................  2 
Certificate & Operation manual

 

 ...................................................................................................  1 

Transportation box

 

 .....................................................................................................................  1 

 

Figure 1. ST-01 Section with installed FP-01C panel 

 

1

 Built-in  card  capture  reader  power  supply  is  provided  either  by  a  separate  power  supply  24VDC -2A  or  

ST-01 

turnstile power  supply (in this case, the power supply should provide general absorbed current not 

less than 8A during 10 seconds).   

2

 Depending on the card thickness (2 mm or 0.9 mm). 

Содержание FP-01C

Страница 1: ...er can be used as a part of PERCo access control systems in this case data is transferred via RS 485 interface from a built in reader of the card capture reader to the PERCo ACS controller Card captur...

Страница 2: ...se without prior notice 2 TECHNICAL SPECIFICATIONS DC operating voltage 21 6 28 V DC Current consumption min 1 81 A Power consumption max 56 W Card container capacity 150 3002 Mean time before failure...

Страница 3: ...ght remains constant 3 If the presented card is a temporary visitor s card and should be withdrawn then the ACS controller sends the signal to the card capture reader control board input Capture card...

Страница 4: ...contact COM 42 V the maximum switching current 200 V Figure 2 Card capture reader control board Card capture reader control board layout is shown in the Fig 2 There are terminal blocks on the board T1...

Страница 5: ...Fig 3 Figure 3 FP 01C Front panel 1 card slot 2 front end indication module 3 container lock 4 container 5 panel fixing hooks 6 built in reader1 7 connection cable of module with indicators1 8 cable f...

Страница 6: ...hooks 5 4 Install back the speed gate glass cover 5 2 Connection layouts of a built in card capture reader Figure 4 Diagram for connecting the card capture reader to the PERCo ACS controllers via RS...

Страница 7: ...FP 01C Front panel for ST 01 Speed gate 7 Figure 5 Diagram for connecting the card capture reader to the ACS controller via Wiegang interface list of components mentioned in the Table 1...

Страница 8: ...t is not backlit Faulty connection or breakdown of power supply cable 9 Faulty power supply unit Replace the cable of the card capture reader 9 Replace the power supply unit The LED indicators are on...

Страница 9: ...Normal state parameter 8 Switch to Additional inputs tab 9 If the card capture reader acts as an external verification device for the controller Card captured signal is sent to a separate input of th...

Страница 10: ...rop down menu set Standard value for Type parameter set Disconnected value for the Normal condition of the contact parameter configure controller response to the activation of the input No 5 by using...

Страница 11: ...ler in parallel with the RC In this case it is also necessary to check In Control mode box on the left side of the Remote control permission window Check boxes of the Verify VISITORS IDs from the exte...

Страница 12: ...lick Save and close button The Device properties window will be closed the settings are saved 5 4 2 CT L14 CT13 configuration in Web interface for working with the card capture reader 1 In Configurati...

Страница 13: ...ing parameter values for input that is physically connected to the Card captured output of the card capture reader Function External verification device confirmation input Operating device 1 number of...

Страница 14: ...capture reader It is necessary to set the type of response on the activation of this input for example activate alarm output 5 Temporary cards for visitors can be issued in Access Users section of the...

Страница 15: ...ication parameter within the External device verification in ACM Control group of parameters set Yes value for the Visitor pass verification parameter and also set the required values for Visitor veri...

Страница 16: ...rolled by the card capture reader Receiver type Activate output Receiver number 3 number of the output that is physically connected to the Capture card input of the card capture reader Response charac...

Страница 17: ...rds section of the Web interface First include them into the main list of cards in the Input subsection then in the List subsection select the proximity card that should be issued for a visitor and in...

Страница 18: ...proper testing operation installation maintenance modification alteration or adjustment damages due to force majeure circumstances natural disasters vandalism etc or defects as a result of external ci...

Страница 19: ...ies with regard to compatibility of a Product purchased with software or products produced by other manufacturers as well as any warranties that this Product will fit for the purposes not stipulated i...

Страница 20: ...e of sale ____________________ 20___ ____________________________________ signature seal Cutting line Warranty Repair Coupon FP 01C Front panel with a built in card capture reader for ST 01 Serial num...

Страница 21: ......

Отзывы: