5.2
Alarms and displayed symbols
Message
Meaning
Action
/ and \ alternatives The pump is currently dosing
Dosing has stopped :
-
Either in the pause cycle
-
Either by the activation
delay
Wait for:
-
The end of the pause cycle
-
The end of the activation delay
CALIBRATION ERR.
Calibration not possible
-
Check state of calibration solution
-
Clean the sensor
-
Replace the sensor
TANK LEVEL LOW
The dosed fluid reservoir is empty
-
Refill the corresponding reservoir
with fluid
MEASURE TOO LOW pH mode : measured pH < 5 pH
REDOX mode : mesurement <
100 mV
Check pool water parameters
TAC > 100 mg/L
Check the status of the probes cable
MEASURE TOO HIGH pH mode: Measured pH > pH 9
REDOX mode: measurement >
900 mV
Check pool water parameters
TAC > 100 mg/L
FILTRATION OFF
The filtration pump is not operating.
The device is therefore paused.
Refer to section 0 page 26 to disable
filtration pump input if you do not want the
DUO unit to pause when the filtration pump
stops.
OVERDOSING ALARM The DOS-ECO unit has dosed more
than the threshold defined in the
settings.
Refer to 0
!
Value on alarm.
Refer to the alarm message displayed on the
screen
Содержание iQntrol DOS-ECO
Страница 1: ...www peraqua com DOS ECO INSTRUCTIONS AND USER MANUAL...
Страница 13: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 13 Positioning on a vertical pipe...
Страница 21: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 21 STEP 12 Installation of the probe pH J1 and Rx J2 2 3 1...
Страница 32: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 32 6 3 Installation of a long probe 120 mm J G P 1 2 3...