Instructions and user manual DOS-ECO
NOT041ENV01_FP1
25
4.4
iQntrol DOS-ECO settings
4.4.1 pH menu
PUMP FLOW RATE
1.5 l/h
OVERDOSING ALARM
0.00 l (OFF)
MEASURE OFFSET
0.0 pH
↓ 7.5pH 720mV↑
LANGUAGE
ENGLISH
PROPORTIONNAL TIME :
proportional from 1 to 60
s/0.1pH
FIXED TIME:
Fixed from 3 to 300s/300s
Tip
PRESS THE
ESC
KEY AT ANY TIME TO
EXIT MENU.
PUMP FLOW RATE :
pH pump flowrate information (no setting)
OVERDOSING ALARM :
Refer to section
Erreur ! Source du renvoi
LANGUAGES :
FRANÇAIS ENGLISH DEUTSCH NEDERLANDS
PORTUGUES ESPAGNOL ITALIANO
MEASURE OFFSET:
From -0.4 to 0.4 pH
PUMP ACTIVA.TYPE
PROPORTIONNAL
PUMP ACTIVATION TYPE :
PROPORTIONNAL (by default) / FIXED
PUMP ACTIVE TIME
20s/0.1pH
CONFIGURATION
pH
CONFIGURATION :
REDOX / pH / SYS
↓7.5pH
SET CAL
DOSING MODE
ACID (pH-)
DOSING MODE :
ACID (pH-)
par défaut
/ ALKALINE (pH+)
720mV ↑
SET CAL