17
- 17 - - 17 - - 17 -
Determining Optimum installation position
The location of the swimming pool heat pump is very important for efficient operation,
think about the following factors when choose the proper place:
Avoidance of air recirculation
Easy for wire and pipe connection and Water pipe line of long water lines (not
longer than 10m.) from heater to pool.
Easy for maintenance.
Drainage of condensation.
Pay attention to the following points:
1
.
The heat pump must be installed OUTSIDE in a well ventilated place to avoid air
recirculation or in a place with adequate room area both for installation and
maintenance. Please refer to the following illustration:
A minimum of 300mm of clearance from walls, shrubbery, equipment, etc. is required around the entire
pump circumference. This allows for ample air intake. No less than 1000mm clearance on the air outlet is
required to prevent re-circulation of air. We recommend not placing the unit underneath eaves, decks, or
porches, as this causes recirculation of discharged air, or the efficiency of the heater will be reduced or
even stopped.
2
.
The heater should be located on a solid, level and non-corrodible structure that is
capable of supporting the weight of the heat pump. It must be fixed by bolts (M10) to
concrete foundation.
!!Warning:
Don’t install the heat pump close to a wall or
plants. And Never inside a closed building!