Pepperl+Fuchs Viator HM-PF-RS232-010001 Скачать руководство пользователя страница 1

Viator

®

 RS-232 HART 

Interface

HM-PF-RS232-010001

PROCESS AUTOMATION

MANUAL

Содержание Viator HM-PF-RS232-010001

Страница 1: ...Viator RS 232 HART Interface HM PF RS232 010001 PROCESS AUTOMATION MANUAL...

Страница 2: ...Delivery for Products and Services of the Electrical Industry published by the Central Association of the Electrical Industry Zentralverband Elektrotechnik und Elektroindustrie ZVEI e V in its most re...

Страница 3: ...ent of this Document 4 1 2 Manufacturer 5 1 3 Target Group Personnel 5 1 4 Symbols Used 6 2 Overview 8 3 Directive Conformity 9 4 Technical Data 10 4 1 RS 232 Pin Connections 13 5 Getting Started 15 5...

Страница 4: ...se can include the following Product identification Delivery transport and storage Mounting and installation Commissioning and operation Maintenance and repair Troubleshooting Dismounting Disposal Not...

Страница 5: ...tation if applicable EU type examination certificate EU declaration of conformity Attestation of conformity Certificates Control drawings Additional documents 1 2 Manufacturer 1 3 Target Group Personn...

Страница 6: ...ith it Read the document carefully 1 4 Symbols Used This document contains symbols for the identification of warning messages and of informative messages Warning Messages You will find warning message...

Страница 7: ...or a sequence of actions Warning This symbol indicates a possible fault or danger Non observance may cause personal injury or serious property damage Caution This symbol indicates a possible fault No...

Страница 8: ...ART compliant It draws power from the RS 232 interface and requires no external power The interface operates on as little as 4 mA It adheres to the EIA RS232C standard and supports hardware handshakin...

Страница 9: ...Viator RS 232 HART Interface Directive Conformity 70137502 2021 12 9 3 Directive Conformity Europe Directive 2014 30 EU EN 61326 1 2013 EN 62368 1 2014 08 Directive 2011 65 EU RoHS EN IEC 63000 2018...

Страница 10: ...4 Technical Data Supply Input current 4 mA Power supply 4 12 V powered by DTR and RS 232 inputs No external power required Interface Interface type RS 232 port Output Signal 0 5 0 1 Vpp trapezoidal wa...

Страница 11: ...OM port Ambient conditions Operating temperature 20 50 C 4 122 F Storage temperature 20 60 C 4 140 F Relative humidity 0 95 non condensing Mechanical specifications Housing length 49 mm Housing width...

Страница 12: ...mm x 15 mm Cable length 1 8 m 2 strand wire terminating in 2 test clips General information Supplementary information Observe the certificates declarations of conformity instruction manuals and manual...

Страница 13: ...ance Ohms Voltage Levels Mark Tr ue Space False Transmit data TXD 3 220 K 2 0 V 12 0 V Data terminal ready DTR 4 pwr supply current DSR load current RXD if true load current CD if true load current 2...

Страница 14: ...data RXD 2 4 V through 220 Ohm if true 4 V through 220 Ohm if false 3 5 V 3 5 V Data set ready DSR 6 Hardwired from DTR DTR Clear to send CTS 8 Hardwired from RTS RTS Ring indicator RI 9 Not used Not...

Страница 15: ...RT field devices 5 2 Connecting to a HART Field Device The Viator RS 232 Interface has a female 9 pin DB 9 serial port for connecting to the computer The standard interface has an integrated 6 foot co...

Страница 16: ...70137502 2021 12 16 Viator RS 232 HART Interface Getting Started Figure 5 1 Connect the test clips 1 across the HART field device or 2 across the load resistor...

Страница 17: ...Viator RS 232 HART Interface Getting Started 70137502 2021 12 17 Warning Do not connect the Viator interface across the power supply This will not allow communication with the HART field device...

Страница 18: ...Pepperl Fuchs Quality Download our latest policy here www pepperl fuchs com quality 70137502 DOCT 5947B 12 2021...