AS-i 3.0 PROFINET Gateway with integr. Safety Monitor
Electrical connection
27
.9.20
13
59
9.10.2
LED indicators - safety unit
The LED’s on the safety unit indicate:
Aux
24 V supply for the semiconductor outputs is present.
1Y.1, 1Y2, 2Y.1, 2Y.2
Input 1.Y1 (EDM 1/Start 1), 2.Y1 (EDM 2/Start 2), 1.Y2 (EDM 3/Start 3),
2.Y2 (EDM 4/Start 4) is turned on.
K1, K2
Contact sets 1.13, 1.14 (K1) resp. 2.13, 2.14 (K2) closed.
K3, K4
semiconductor output 3.14 (K3) resp.4.14 (K4) is turned on.
1.Y1
Aux
2.Y1
K1
K3
1.Y2
2.Y2
K2
K4
2.13
+3
24 V
2.Y1
0 V
+4
1.13
2.Y2
1.Y2
2.14
+2
4.14
+1
1.14
1.Y1
3.14
Information!
If there is no auxiliary voltage connection available, LEDs are turned off, even if the
corresponding release circuit is turned on.