Subject to reasonable modifications due to technical advances.
© Fuchs, Printed in Germany
53
Fuchs Group · Tel.: Germany (6 21) 7 76-0 · USA (3 30) 4 25 35 55 · Singapore 7 79 90 91
Internet http://www.pepperl-fuchs.com
Iss
u
e d
a
te
: 17
.4
.20
09
AS-Interface
Function and startup of the Safety Monitor
The menu can be exited by pressing the ESC/Service key without changing the
data.
8.7.2
Safe data
This section describes the system behavior of the safe unit when using the chip
card.
In general the safe part of the chip card has 4 memory banks (A…D). A bank is
referred to as an active bank. Unless otherwise stated, the operations described
in the following are always performed on the active bank.
8.7.2.1
Data incompatible
If a card with incompatible data is found, the following error message is output:
CHIPCARD AND
AS-I DATA
DIFFERENT
CARD->MASTER
MASTER->CARD
CONTINUE
Command
Description
CHIP CARD>MASTER
Chip card data are copied to the master
MASTER->CHIPCARD
Master data are copied to the chip card
NEXT
No change to the data
CHIPCARD NOT
COMPATIBLE