VBA-2E-KE5-IJL/UJL

Certificates and Approvals

2

Certificates and Approvals

2.1

UL Information

Technical Data and Environmental Conditions

This device is for indoor use only.

This device may be operated in altitudes up to 2000 m.

The ambient temperature range is from -25 

°

C to +70 

°

C.

The device must be installed in accordance with applicable national laws and regulations.

If the device is used in a manner not specified by the manufacturer, the protection provided by 
the equipment may be impaired.

The device must be installed in a switch cabinet or switch box that meets protection class IP54 
as a minimum.

Содержание VBA-2E-KE5-IJL

Страница 1: ...A D Spec 2 1 VBA 2E KE5 IJL UJL AS Interface Analog Module FACTORY AUTOMATION MANUAL...

Страница 2: ...s of Delivery for Products and Services of the Electrical Indus try published by the Central Association of the Electrical Industry Zentralverband Elektrotechnik und Elektroindustrie ZVEI e V in its m...

Страница 3: ...cally Detected Sensor Types 9 4 Installation 10 4 1 Storage and Transport 10 4 2 Unpacking 10 4 3 Mounting 10 4 4 Connecting AS Interface Auxiliary Voltage 10 4 5 Connecting the Sensors 11 5 Commissio...

Страница 4: ...able EU type examination certificate EU declaration of conformity Attestation of conformity Certificates Control drawings Instruction manual Other documents 1 2 Target Group Personnel Responsibility f...

Страница 5: ...ayed in descending order as follows Informative Symbols Action This symbol indicates a paragraph with instructions You are prompted to perform an action or a sequence of actions Danger This symbol ind...

Страница 6: ...rated in altitudes up to 2000 m The ambient temperature range is from 25 C to 70 C The device must be installed in accordance with applicable national laws and regulations If the device is used in a m...

Страница 7: ...g indicators and operating elements LED Indicators Description Function FAULT LED Fault indication LED red red communication fault or address is 0 red flashing peripheral fault INT LED Internal input...

Страница 8: ...UX Name Description ADDR Addressing socket extra low voltage switch socket 1 3 mm IU 1 IU 1 IU 2 IU 2 Voltage at analog inputs II1 II2 Current at analog inputs L Sensor supply GND Reference potential...

Страница 9: ...ensor Types Any sensor types saved through automatic detection are reset when the input configuration of the module is manually changed For this there are two available options 1 Switch off the module...

Страница 10: ...apping it onto a 35 mm DIN rail in compliance with EN 50022 Unlocking Terminal Blocks Proceed as follows to unlock and eject terminal blocks Figure 4 1 Unlocking terminals 4 4 Connecting AS Interface...

Страница 11: ...Source Voltage input IU1 IU2 Current input II1 II2 2 wire 3 wire 4 wire Connection example or L IU IU GND GND S S S S L II GND AUX INT AUX INT Voltage input IU1 IU2 Current input II1 II2 2 wire 3 wire...

Страница 12: ...on The following parameters can be set for the VBA 2E KE5 IJL UJL Program the parameters using an AS Interface master with the VAZ SW ACT32 AS i Control Tools from Pepperl Fuchs or with the VBP HH1 V3...

Страница 13: ...ED and FAULT LED flash in the event of a peripheral fault and a message is sent to the master A peripheral fault is always output independently of parameter P2 if The power supply is overloaded The ex...

Страница 14: ...Data outside the measuring range Check connected sensors for wire break short circuit Wrong sensor type configured A different sensor type has already been configured through automatic detection of se...

Страница 15: ...On Extended range 1 4 20 4000 20000 On Nominal range 1 3999 1000 3999 On Extended range 1 1 Measurement accuracy corresponds to the nominal range 1 32767 Below threshold peripheral fault Table 7 1 Mea...

Страница 16: ...case the transmission of a channel via AS Interface starts just before the conversion of this channel is completed within the module This gives rise to two scenarios 1 The conversion time is longer th...

Страница 17: ...tive P0 1 70 ms Table 7 4 Module Analog to digital conversion Channel 1 Analog to digital conversion Channel 2 Analog to digital conversion Channel 1 Transmission Channel 1 Transmission Channel 2 Tran...

Страница 18: ...of occupied addresses in the AS interface network An address is considered occupied if one of the following configurations apply A standard address is assigned e g 1 An A or B Address is assigned e g...

Страница 19: ...hs GmbH 68307 Mannheim Germany Tel 49 621 776 0 E mail info de pepperl fuchs com USA Headquarters Pepperl Fuchs Inc Twinsburg Ohio 44087 USA Tel 1 330 4253555 E mail sales us pepperl fuchs com Asia Pa...

Отзывы: